9 resultados para Subtraction

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D experimental data analysed with subtractive imaging, the equivalent Fourier-space processing of the confocal data only, and Fourier-space weighted averaging is presented. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments were conducted to test the hypothesis that toddlers have access to an analog-magnitude number representation that supports numerical reasoning about relatively large numbers. Three-year-olds were presented with subtraction problems in which initial set size and proportions subtracted were systematically varied. Two sets of cookies were presented and then covered The experimenter visibly subtracted cookies from the hidden sets, and the children were asked to choose which of the resulting sets had more. In Experiment 1, performance was above chance when high proportions of objects (3 versus 6) were subtracted from large sets (of 9) and for the subset of older participants (older than 3 years, 5 months; n = 15), performance was also above chance when high proportions (10 versus 20) were subtracted from the very large sets (of 30). In Experiment 2, which was conducted exclusively with older 3-year-olds and incorporated an important methodological control, the pattern of results for the subtraction tasks was replicated In both experiments, success on the tasks was not related to counting ability. The results of these experiments support the hypothesis that young children have access to an analog-magnitude system for representing large approximate quantities, as performance on these subtraction tasks showed a Webers Law signature, and was independent of conventional number knowledge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study of the gamma-radiolysis of the commercial polymers U-polymer, UP (Unitake) and polycarbonate, PC, (Aldrich) has been undertaken using ESR spectroscopy. The G-value of radical formation at 77 K has been found to be 0.31 +/- 0.01 for UP and 0.5 +/- 0.02 for PC. By using thermal annealing and spectral subtraction, the paramagnetic species formed on irradiation has been assigned. The effect of radiation on the chemical structure of UP and PC has been investigated at ambient temperature and at 423 K. The NMR results show that a new phenol type chain end is formed in the polymers on exposure to gamma-radiation. The G-value of formation of the new phenol ends was estimated to be 0.7 for PC (423 K) and 0.4 for UP (300 K). (C) 1998 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radical formation in ultem following gamma-radiolysis has been reassessed, and the G(R*) values at different temperatures have been determined by ESR spectroscopy. The radical assignment and radical reactivity have been re-examined by photobleaching and thermal annealing studies. Photobleachable radical anions were found to comprise approximate to40% of the total number of radicals formed on radiolysis at 77 K. Spectral subtraction methods, ESR spectral simulations, measurement of g-values and the hyperfine splitting constants were used to identify the other radical intermediates. The principal chain scission radicals are formed due to scission of the main-chain at (i) the ether linkage, (ii) the isopropylidene group and (iii) the imide ring in the main chain. The side chain methyl groups of the isopropylidine units also lose hydrogen to form methylene radicals. The five-line spectrum observed to decay in the temperature range 370-430 K, which has not been assigned previously, has been identified as being characteristic of a di-substituted benzyl radical. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Because there is discordance between different immunoassay values for serum hGH, and because clinical state may not correlate with immunoreactive hGH, we have developed an assay to accurately measure serum hGH somatogenic bioactivity. The results of this assay were compared with the Elegance two-site ELISA assay across 135 patient samples in a variety of clinical states. DESIGN The somatogenic assay was based on stable expression of hGH receptor in the murine BaF line, allowing these cells to proliferate in response to hGH. To eliminate interference by other growth factors in serum, we created a specific antagonist of the hGH receptor (similar to Trovert or Pegvisomant) which allowed us to obtain a true measure of hGH somatogenic activity by subtraction of the activity in the presence of the antagonist. The assay was carried out in microtiter plates over 24 h, with oxidation of a chromogenic tetrazolium salt (MTT) as the endpoint. PATIENTS These encompassed a number of different clinical conditions related to short stature, including idiopathic short stature, neurosecretory dysfunction and renal failure, as well as obese patients on dietary restriction and normal volunteers. MEASUREMENTS In addition to the colourimetric (MTT) response to hGH, we measured free hGH by stripping out GHBP-bound hGH using beads coupled to a monoclonal antibody to the GHBP (GH binding protein). All samples were measured in both bioassay and ELISA assay. RESULTS This bioassay was sensitive (5 mU/l or 2 mug/l) and precise, and not subject to interference by the GHBP. There was a good correlation (r = 0.95) between bioactivity and immunoactivity across clinical states. There was, however, an increased bioactivity during secretory peaks (over 25 mU/l), which has been reported previously for the Nb2 bioassay. Free hGH did not correlate with clinical state. CONCLUSIONS Because the results of the Elegance ELISA and the bioassay correlate well, even though there is greater bioactivity at higher hormone concentrations, it is evident that an appropriate immunoassay is able to act as a reliable indicator for clinical assessment. In those rare cases where bio-inactive GH exists, our bioassay should provide an appropriate means to demonstrate this.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the construction of the mouse full-length cDNA encyclopedia, the most extensive view of a complex transcriptome, on the basis of preparing and sequencing 246 libraries. Before cloning, cDNAs were enriched in full-length by Cap-Trapper, and in most cases, aggressively subtracted/normalized. We have produced 1,442,236 successful 3'-end sequences clustered into 171,144 groups, from which 60,770 clones were fully sequenced cDNAs annotated in the FANTOM-2 annotation. We have also produced 547,149 5' end reads, which clustered into 124,258 groups. Altogether, these cDNAs were further grouped in 70,000 transcriptional units (TU), which represent the best coverage of a transcriptome so far. By monitoring the extent of normalization/subtraction, we define the tentative equivalent coverage (TEC), which was estimated to be equivalent to >12,000,000 ESTs derived from standard libraries. High coverage explains discrepancies between the very large. numbers of clusters (and TUs) of this project, which also include non-protein-coding RNAs, and the lower gene number estimation of genome annotations. Altogether, S'-end clusters identify regions that are potential promoters for 8637 known genes and S'-end clusters suggest the presence of almost 63,000 transcriptional starting points. An estimate of the frequency of polyadenylation signals suggests that at least half of the singletons in the EST set represent real mRNAs. Clones accounting for about half of the predicted TUs await further sequencing. The continued high-discovery rate suggests that the task of transcriptome discovery is not yet complete.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Angiography is usually performed as the preoperative road map for those requiring revascularization for lower extremity peripheral arterial disease (PAD). The alternative investigations are ultrasound, 3-D magnetic resonance angiography (3-D MRA) and computed tomography angiography. This pilot study aimed to assess whether 3-D MRA could replace the gold standard angiography in preoperative planning. Eight patients considered for aortoiliac or infrainguinal arterial bypass surgery were recruited. All underwent both imaging modalities within 7 days. A vascular surgeon and a radiologist each reported on the images from both the 3-D MRA and the angiography, with blinding to patient details and each others reports. Comparisons were made between the reports for the angiographic and the 3-D MRA images, and between the reports of the vascular surgeon and the radiologist. Compared to the gold standard angiogram, 3-D MRA had a sensitivity of 77% and specificity of 94% in detecting occlusion, and a sensitivity of 72% and specificity of 90% in differentiating high grade (> 50%) versus low grade (< 50%) stenoses. There was an overall concordance of 78% between the two investigations with a range of 62% in the peroneal artery to 94% in the aorta. 3-D MRA showed flow in 23% of cases where conventional angiography showed no flow. In the present pilot study, 3-D MRA had reasonable concordance with the gold standard angiography, depending on the level of the lesion. At times it showed vessel flow where occlusion was shown on conventional angiogram. 3-D MRA in peripheral vascular disease is challenging the gold standard, but is inconsistent at present.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The XPS peaks of Fe 3p for Fe2+ and Fe3+ in FeO and Fe2O3, respectively, have been measured and the effects of curve fitting parameters on interpretation of the data have been analysed. Firstly, the peak fit parameters, i.e. (1) the number of peaks to be deconvoluted, (2) the range of the peak for back ground subtraction, (3) straight line (Li) or the Shirley (Sh) background subtraction method, (4) GL ratio (the ratio of Gaussian and Lorentzian contribution to the peak shape) and (5) asymmetry factor (AS), are manually selected. Secondly, the standard peak fit parameters were systematically investigated. The peak shape was fitted to a Voigt function by changing the peak position, the peak height and the full width at half maximum (FWHM) to minimize the chi(2). The recommended peak positions and peak parameters for Fe2+ and Fe3+ in iron oxides have been determined. (c) 2006 Elsevier B.V. All rights reserved.