155 resultados para Stress testing

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the application of linearly increasing stress testing (LIST) to the study of stress corrosion cracking (SCC) of carbon steel in 4 N NaNO3 and in Bayer liquor. LIST is similar to the constant extension-rate testing (CERT) methodology with the essential difference that the LIST is load controlled whereas the CERT is displacement controlled. The main conclusion is that LIST is suitable for the study of the SCC of carbon steels in 4 N NaNO3 and in Bayer liquor. The low crack velocity in Bayer liquor and a measured maximum stress close to that of the reference specimen in air both indicate that a low applied stress rate is required to study SCC in this system. (C) 1998 Chapman & Hall.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE - This study sought to determine whether stress echocardiography using exercise (when feasible) or dobutamine echo could be used to predict mortality in patients with diabetes. RESEARCH DESIGN AND METHODS - Stress echo was performed in 937 patients with diabetes (aged 59 +/- 13 years, 529 men) for symptom evaluation (42%) and follow-up of known coronary artery disease (CAD) (58%). Stress echocardiography using exercise was performed in 333 patients able to exercise maximally, and dobutamine echo using a standard dobutamine stress was used in 604 patients. Patients were followed for less than or equal to9 years (mean 3.9 +/- 2.3) for all-cause mortality. RESULTS - Normal studies were obtained in 567 (60%) patients; 29% had resting left ventricular (LV) dysfunction, and 25% had ischemia. Abnormalities were confined to one territory in 183 (20%) patients and to multiple territories in 187 (20%) patients. Death (in 275 [29%] patients) was predicted by referral for pharmacologic stress (hazard ratio [HR] 3.94, P < 0.0001), ischemia (1.77, P <0.0001), age (1.02, P = 0.002), and heart failure (1.54, P = 0.01). The risk of death in patients With a normal scan was 4% per year, and this was associated with age and selection for pharmacologic stress testing. In stepwise models replicating the sequence of clinical evaluation, the predictive power of independent clinical predictors (age, selection for pharmacologic stress, previous infarction, and heart failure; model chi(2) = 104.8) was significantly enhanced by addition of stress echo data (model chi(2) = 122.9). CONCLUSIONS - The results of stress echo are independent predictors of death in diabetic patients with known or suspected CAD.. Ischemia adds risk that is incremental to clinical risks and LV dysfunction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stress echocardiography has been shown to improve the diagnosis of coronary artery disease in the presence of hypertension, but its value in prognostic evaluation is unclear. We sought to determine whether stress echocardiography could be used to predict mortality in 2363 patients with hypertension, who were followed for up to 10 years (mean 4.0+/-1.8) for death and revascularization. Stress echocardiograms were normal in 1483 patients (63%), 16% had resting left ventricular (LV) dysfunction alone, and 21% had ischemia. Abnormalities were confined to one territory in 489 patients (21%) and to multiple territories in 365 patients (15%). Cardiac death was less frequent among the patients able to exercise than among those undergoing dobutamine echocardiography (4% versus 7%, P<0.001). The risk of death in patients with a negative stress echocardiogram was <1% per year. Ischemia identified by stress echocardiography was an independent predictor of mortality in those able to exercise (hazard ratio 2.21, 95% confidence intervals 1.10 to 4.43, P=0.0001) as well as those undergoing dobutamine echo (hazard ratio 2.39, 95% confidence intervals 1.53 to 3.75, P=0.0001); other predictors were age, heart failure, resting LV dysfunction, and the Duke treadmill score. In stepwise models replicating the sequence of clinical evaluation, the results of stress echocardiography added prognostic power to models based on clinical and stress-testing variables. Thus, the results of stress echocardiography are an independent predictor of cardiac death in hypertensive patients with known or suspected coronary artery disease, incremental to clinical risks and exercise results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The risk of cardiac events in patients undergoing major noncardiac surgery is dependent on their clinical characteristics and the results of stress testing. The purpose of this study was to develop a composite approach to defining levels of risk and to examine whether different approaches to prophylaxis influenced this prediction of outcome. One hundred forty-five consecutive patients (aged 68 +/- 9 years, 79 men) with >1 clinical risk variable were studied with standard dobutamine-atropine stress echo before major noncardiac surgery. Risk levels were stratified according to the presence of ischemia (new or worsening wall motion abnormality), ischemic threshold (heart rate at development of ischemia), and number of clinical risk variables. Patients were followed for perioperative events (during hospital admission) and death or infarction over the subsequent 16 10 months. Ten perioperative events occurred in 105 patients who proceeded to surgery (10%, 95% confidence interval [CI] 5% to 17%), 40 being cancelled because of cardiac or other risk. No ischemia was identified in 56 patients, 1 of whom (1.8%) had a perioperative infarction. Of the 49 patients with ischemia, 22 (45%) had 1 or 2 clinical risk factors; 2 (9%, 95% CI 1% to 29%) had events. Another 15 patients had a high ischemic threshold and 3 or 4 risk factors; 3 (20%, 95% Cl 4% to 48%) had events. Twelve patients had a low ischemic threshold and 3 or 4 risk factors; 4 (33%, 95% CI 10% to 65%) had events. Preoperative myocardial revascularization was performed in only 3 patients, none of whom had events. Perioperative and long-term events occurred despite the use of beta blockers; 7 of 41 eta blocker-treated patients had a perioperative event (17%, 95% CI 7% to 32%); these treated patients were at higher anticipated risk than untreated patients (20 +/- 24% vs 10 +/- 19%, p = 0.02). The total event rate over late follow-up was 13%, and was predicted by dobutamine-atropine stress echo results and heart rate response. (C) 2002 by Excerpta Medica, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Impaired coronary flow reserve is widely reported in diabetes mellitus (DM) but its effect on myocardial contrast echocardiography (MCE) is unclear. We sought to identify whether DM influences the accuracy of qualitative and quantitative assessment of coronary artery disease (CAD) using MCE in 83 patients who underwent coronary angiography (60 men, 27 with DM; 56 +/- 11 years;). Destruction replenishment imaging was performed at rest and after combined dipyridamole-exercise stress testing. Ischemia was identified by the development of new wall motion abnormalities, qualitative MCE (new perfusion defects apparent 1 second after flash during hyperemia), and quantitative MCE (myocardial blood flow reserve < 2.0 in the anterior circulation). Qualitative and quantitative assessment of perfusion was feasible in 100% and 92% of patients, respectively. Significant left anterior descending coronary stenosis (> 50% by quantitative angiography) was present in 28 patients (including 8 with DM); 55 patients had no CAD (including 19 with DM). The myocardial blood flow reserve was reduced in patients with coronary stenosis compared with those with no CAD (1.6 +/- 1.1 vs 3.8 +/- 2.5, p < 0.001). Among patients with no CAD, those with DM had an impaired flow reserve compared with control patients without DM (2.4 +/- 1.0 vs 4.5 +/- 2.8, p = 0.003). In conclusion, DM significantly influenced the quantitative, but not the qualitative, assessment of MCE, with a marked reduction in specificity in patients with DM. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background The prevalence of left ventricular hypertrophy (LVH), coronary artery disease, and subclinical cardiomyopathy in diabetic patients without known cardiac disease is unclear. We sought the frequency of these findings to determine whether plasma brain natriuretic peptide (BNP) could be used as an alternative screening tool to identify subclinical LV dysfunction. Methods Asymptomatic patients with diabetes mellitus without known cardiac disease (n = 10 1) underwent clinical evaluation, measurement of BNP, exercise stress testing, and detailed echocardiographic assessment. After exclusion of overt dysfunction or ischemia, subclinical myocardial function was sought on the basis of myocardial systolic (Sm) and diastolic velocity (Em). Association was. sought between subclinical dysfunction and clinical, biochemical, exercise, and echocardiographic variables. Results Of 101 patients, 22 had LVH and 16 had ischemia evidenced by exercise-induced wall motion abnormalities. Only 4 patients had abnormal BNP levels; BNP was significantly increased in patients with LVH. After exclusion of LVH and coronary artery disease, subclinical cardiomyopathy was identified in 24 of 66 patients: Subclinical disease could not be predicted by BNP. Conclusions Even after exclusion of asymptomatic ischemia and hypertrophy, subclinical systolic and diastolic dysfunction occurs in a significant number of patients with type 2 diabetes. However, screening approaches, including BNP, do not appear to be sufficiently sensitive to identify subclinical dysfunction, which requires sophisticated echocardiographic analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Strain and strain rate (SR) are measures of deformation that are basic descriptors of both the nature and the function of cardiac tissue. These properties may now be measured using either Doppler or two-dimensional ultrasound techniques. Although these measurements are feasible in routine clinical echocardiography, their acquisition and analysis nonetheless presents a number of technical challenges and complexities. Echocardiographic strain and SR imaging has been applied to the assessment of resting ventricular function, the assessment of myocardial viability using low-dose dobutamine infusion, and stress testing for ischemia. Resting function assessment has been applied in both the left and the fight ventricles, and may prove particularly valuable for identifying myocardial diseases and following up the treatment response. Although the evidence base is limited, SR imaging seems to be feasible and effective for the assessment of myocardial viability. The use of the technique for the detection of ischemia during stress echocardiography is technically challenging and likely to evolve further. The clinical availability of strain and SR measurement may offer a solution to the ongoing need for quantification of regional and global cardiac function. Nonetheless, these techniques are susceptible to artifact, and further technical development is necessary.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study examined the utility of a stress/coping model in explaining adaptation in two groups of people at-risk for Huntington's Disease (HD): those who have not approached genetic testing services (non-testees) and those who have engaged a testing service (testees). The aims were (1) to compare testees and non-testees on stress/coping variables, (2) to examine relations between adjustment and the stress/coping predictors in the two groups, and (3) to examine relations between the stress/coping variables and testees' satisfaction with their first counselling session. Participants were 44 testees and 40 non-testees who completed questionnaires which measured the stress/coping variables: adjustment (global distress, depression, health anxiety, social and dyadic adjustment), genetic testing concerns, testing context (HD contact, experience, knowledge), appraisal (control, threat, self-efficacy), coping strategies (avoidance, self-blame, wishful thinking, seeking support, problem solving), social support and locus of control. Testees also completed a genetic counselling session satisfaction scale. As expected, non-testees reported lower self-efficacy and control appraisals, higher threat and passive avoidant coping than testees. Overall, results supported the hypothesis that within each group poorer adjustment would be related to higher genetic testing concerns, contact with HD, threat appraisals, passive avoidant coping and external locus of control, and lower levels of positive experiences with HD, social support, internal locus of control, self-efficacy, control appraisals, problem solving, emotional approach and seeking social support coping. Session satisfaction scores were positively correlated with dyadic adjustment, problem solving and positive experience with HD, and inversely related to testing concerns, and threat and control appraisals. Findings support the utility of the stress/coping model in explaining adaptation in people who have decided not to seek genetic testing for HD and those who have decided to engage a genetic testing service.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to understand rock bolt Stress Corrosion Cracking (SCC), a series of experiments have been performed in Linearly Increasing Stress Test (LIST) apparatus. One series of experiments determined the threshold stress of various bolt metallurgies (900 MPa for Steel A, and 800 MPa for Steel B and C). The high values of threshold stress suggest that SCC begins in rock bolts when they are sheared by moving rock strata. Typical crack velocity values have been measured to be 2.5 x 10(-8) m s(-1), indicating that there is not much benefit for rock bolt steel of higher fracture toughness. Another series of experiments were performed to understand the environmental conditions causing SCC of steel A and galvanised Steel A rock bolt steel. SCC only occurred for environmental conditions for which produce hydrogen on the sample surface, leading to hydrogen embrittlement and SCC. Fracture surfaces of LIST samples failed by SCC were found to display the same fracture regions as fracture surfaces of rock bolts failed in service by SCC: Tearing Topography Surface (TTS), Corrugated Irregular Surface (CIS), quasi Micro Void Coalescence (qMVC) and Fast Fracture Surface (FFS). Water chemistry analysis were carried out on samples collected from various Australian mines in order to compare laboratory electrolyte conditions to those found in underground mines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rock bolt stress corrosion cracking (SCC) has been investigated using the linearly increasing stress test (LIST). One series of experiments determined the threshold stress of various bolt metallurgies (900 MPa for 1355AXRC, and 800 MPa for MAC and MA840B steels). The high values of threshold stress suggest that SCC begins in rock bolts when they are sheared by moving rock strata. SCC only occurred for environmental conditions which produce hydrogen on the sample surface, leading to hydrogen embrittlement and SCC. Different threshold potentials were determined for a range of metallurgies. Cold work was shown to increase the resistance of the steel to SCC. Rock bolt rib geometry does not have a direct impact on the SCC resistance properties of the bolt, although the process by which the ribs are produced can introduce tensile stresses into the bolt which lower its resistance to SCC. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stress corrosion cracking (SCC) behavior and pre-exposure embrittlement of AZ31 magnesium alloy have been studied by slow strain rate tensile (SSRT) tests in this paper. It is showed that AZ31 sheet material is susceptible to SCC in distilled water, ASTM D1.387 solution, 0.01 M NaCl and 0.1 M NaCl solution. The AZ31 magnesium alloy also becomes embrittled if pre-exposed to 0.01 M NaCl solution prior to tensile testing. The degree of embrittlement increased with increasing the pre-exposure time, It is proposed that both the pre-exposure embrittlement and SCC were due to hydrogen which reduces the cohesive strength. i,e,. hydrogen embrittlement, (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combination of modelling and analysis techniques was used to design a six component force balance. The balance was designed specifically for the measurement of impulsive aerodynamic forces and moments characteristic of hypervelocity shock tunnel testing using the stress wave force measurement technique. Aerodynamic modelling was used to estimate the magnitude and distribution of forces and finite element modelling to determine the mechanical response of proposed balance designs. Simulation of balance performance was based on aerodynamic loads and mechanical responses using convolution techniques. Deconvolution was then used to assess balance performance and to guide further design modifications leading to the final balance design. (C) 2001 Elsevier Science Ltd. All rights reserved.