7 resultados para Strength measurement
em University of Queensland eSpace - Australia
Resumo:
This paper presents investigations into an indoor 2×2 multiple input multiple output (MIMO) system, whose diversity performance is assessed using a high precision test-bed. In this system, transmitter and receiver are equipped with 180° or 90° 3dB hybrids with their two output ports terminated with co-polar monopole antennas. By feeding a signal to one of the two input ports of the hybrid (while the other input port is matched terminated) different communication channels in a rich-scattering environment can be created. The test-bed allows for the signal strength measurements around the receiver/ transmitter sides for a given feeding configuration of hybrids when the receiver is moved over a circular region in an indoor environment. The signal strengths maps obtained for various modes of this 2×2 MIMO system are foundations for investigating transmit/receive diversity schemes. As the signal strength measurement results are obtained with Bluetooth modules operating in the ISM 2.4 GHz, the results are of importance to many other wireless systems that aim at utilizing MIMO diversity schemes to enhance their performance in this frequency band.
Resumo:
Introduction/Purpose: The role of impact loading activity on bone mass is well established; however, there are little data on the effects of exercise on bone geometry and indices of bone strength. The primary purpose of this study was to compare indices of bone strength at the proximal femur (PF) between elite premenarcheal gymnasts (N = 30) and age-matched controls (N = 30). Methods: Structural properties of the proximal femur were derived from the hip analyses program and included measurement of subperiosteal width, endosteal diameter, cross-sectional area, bone mineral density, cross-section moment of inertia (CSMI), and section modulus (Z). These parameters were measured for two regions of the PF: the narrow neck (NN), and the shaft (S). In addition, a strength index (S-SI) was calculated at the shaft by dividing the Z at the shaft by the femur length. A secondary purpose was to compare bone mineral content (BMC) values at the total body, lumbar spine, and three sites at the PF (neck, trochanter, and total) between the groups. All dependent values were compared adjusting for height and weight using an ANCOVA procedure and for relative lean body mass post hoc. Results: The gymnasts had significantly greater size-adjusted strength indices (CSMI, Z, and SI) at the NN and S. Gymnasts also had significantly greater size-adjusted BMC at all sites investigated. However, these differences disappeared when adjusted for relative lean body mass. Conclusion: When adjusted for body size, gymnasts had significantly greater indices of both axial strength and bending strength at the NN region of the PF and S, as well as a greater bone SI at the femoral shaft. These differences may be related to greater relative lean body mass attained in gymnastics training.
Resumo:
We experimentally determine weak values for a single photon's polarization, obtained via a weak measurement that employs a two-photon entangling operation, and postselection. The weak values cannot be explained by a semiclassical wave theory, due to the two-photon entanglement. We observe the variation in the size of the weak value with measurement strength, obtaining an average measurement of the S-1 Stokes parameter more than an order of magnitude outside of the operator's spectrum for the smallest measurement strengths.
Resumo:
The efficiency of numerous mineral processing operations can be determined by measuring the magnetic properties of the process streams. This measurement, if done at all, is currently performed by laboratory testing of spot samples. This is an inherently slow process and, where feed grades are variable, optimum performance is generally not achieved. This paper describes the rapid measurement of the magnetic properties of minerals. AC measurement techniques, including the analysis of the phase component of the magnetic vector; frequency dependent magnetic susceptibility and the effect of applied magnetic field strength will be discussed. Industrial applications in mineral sands, copper smelting, ferrosilicon testing and drill core scanning will be reported. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The measurement of exchangeable cations in saline soils is limited by the difficulty in accurately separating soluble cations from exchangeable cations. A method is examined for saline soils in which exchangeable cations are calculated as the total extractable cations minus the concentration of soil solution (soluble) cations. In addition, a further two standard methods were investigated, one which assumes the total soil extractable cations are exchangeable, the other utilises a pretreatment to remove soluble salts prior to measurement of the remaining (exchangeable) cations. After equilibration with a range of sodium adsorption ratio (SAR) solutions at various ionic strengths, the exchangeable cation concentrations of two soils (Dermosol and Vertosol) were determined by these methods and compared to known values. The assumption that exchangeable cations can be estimated as the total soil extractable cations, although valid at low ionic strength, resulted in an overestimation of exchangeable Na and Ca concentrations at higher ionic strengths due to the presence of soluble salts. Pretreatment with ethanol and glycerol was found to effectively remove soluble salts thus allowing the accurate measurement of the effective cation exchange capacity (ECEC), however, dilution associated with the pretreatment process decreased concentrations of exchangeable Ca while simultaneously increasing exchangeable Na. Using the proposed method, good correlations were found between known and measured concentrations of exchangeable Na (Dermosol: y=0.873x and Vertosol: y=0.960x) and Ca (Dermosol: y=0.906x, and Vertosol: y=1.05x). Therefore, for soils with an ionic strength of approximately 50 mM (ECse 4 dS m-1) or greater (in which exchangeable cation concentrations are overestimated by assuming the total soil cations are exchangeable), concentrations can be calculated as difference between total extractable cations and soluble cations.
Resumo:
Drawing on extensive academic research and theory on clusters and their analysis, the methodology employed in this pilot study (sponsored by the Welsh Assembly Government’s Economic Research Grants Assessment Board) seeks to create a framework for reviewing and monitoring clusters in Wales on an ongoing basis, and generate the information necessary for successful cluster development policy to occur. The multi-method framework developed and tested in the pilot study is designed to map existing Welsh sectors with cluster characteristics, uncover existing linkages, and better understand areas of strength and weakness. The approach adopted relies on synthesising both quantitative and qualitative evidence. Statistical measures, including the size of potential clusters, are united with other evidence on input-output derived inter-linkages within clusters and to other sectors in Wales and the UK, as well as the export and import intensity of the cluster. Multi Sector Qualitative Analysis is then designed for competencies/capacity, risk factors, markets, types and crucially, the perceived strengths of cluster structures and relationships. The approach outlined above can, with the refinements recommended through the review process, provide policy-makers with a valuable tool for reviewing and monitoring individual sectors and ameliorating problems in sectors likely to decline further.
Resumo:
The paper describes a system for measuring radiation efficiency of a small antenna operating alone or in the presence of objects similar to those as in an actual service. The system applies the direct approach to determining the antenna efficiency by measuring the radiated field over the entire sphere surrounding the tested antenna. In order to overcome problems associated with the conventional measuring equipment, the antenna under test is equipped with a miniature built-in VCO signal generator and supported by a low reflectivity dielectric positioner. The positioner is of sufficient size and strength to hold a human head phantom to investigate changes in radiation characteristics when the antenna operates in the presence of a human operator.