7 resultados para Stimulus intensity

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prepulse inhibition of the blink reflex is widely applied to investigate information processing deficits in schizophrenia and other psychiatric patient groups. The present experiment investigated the hypothesis that prepulse inhibition reflects a transient process that protects preattentive processing of the prepulse. Participants were presented with pairs of blinkeliciting noises, some preceded by a prepulse at a variable stimulus onset asynchrony (SOA), and were asked to rate the intensity of the second noise relative to the first. Inhibition of blink amplitude was greater for a 110-dB (A) noise than for a 95-dB(A) noise with a 120-ms SOA, whereas there was no difference with a 30-ms SOA. The perceived intensity was also lower for the 110-dB(A) noise than for the 95-dB(A) noise with the 120-ms SOA, but not with the 30-ms SOA. The parallel results support a relationship between prepulse inhibition of response amplitude and perceived intensity. However, the prepulse did not reduce intensity ratings relative to control trials in some conditions, suggesting that prepulse inhibition is not always associated with an attenuation of the perceived impact of the blink-eliciting stimulus.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The blink reflex is modulated if a weak lead stimulus precedes the blink-eliciting stimulus. In two experiments, we examined the effects of the sensory modality of the lead and blink-eliciting stimuli on blink modulation. Acoustic, visual, or tactile lead stimuli were followed by an acoustic (Experiment 1) or an electrotactile (Experiment 2) blink-eliciting stimulus at lead intervals of -30, 0, 30, 60, 120, 240, 360, and 4,500 msec. The inhibition of blink magnitude at the short (60- to 360-msec) lead intervals and the facilitation of blink magnitude at the long (4,500-msec) lead interval observed for each lead stimulus modality was relatively unaffected by the blink-eliciting stimulus modality. The facilitation of blink magnitude at the very short (-30- to 30-msec) lead intervals was dependent on the combination of the lead and the blink-eliciting stimulus modalities. Modality specific and nonspecific processes operate at different levels of perceptual processing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The behavior and stability of motor units (MUs) in response to electrical stimulation of different intensities can be assessed with the stimulus-response curve, which is a graphical representation of the size of the compound muscle action potential (CMAP) in relation to stimulus intensity. To examine MU characteristics across the whole stimulus range, the variability of CMAP responses to electrical stimulation, and the differences that occur between normal and disease states, the curve was studied in 11 normal subjects and 16 subjects with amyotrophic lateral sclerosis (ALS). In normal subjects, the curve showed a gradual increase in CMAP size with increasing stimulus intensity, although one or two discrete steps were sometimes observed in the upper half of the curve, indicating the activation of large MUs at higher intensities. In ALS subjects, large discrete steps, due to loss of MUs and collateral sprouting, were frequently present. Variability of the CMAP responses was greater than baseline variability, indicating variability of MU responses, and at certain levels this variability was up to 100 mu Vms. The stimulus-response curve shows differences between normal and ALS subjects and provides information on MU activation and variability throughout the curve.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, we describe an algorithm that automatically detects and labels peaks I - VII of the normal, suprathreshold auditory brainstem response (ABR). The algorithm proceeds in three stages, with the option of a fourth: ( 1) all candidate peaks and troughs in the ABR waveform are identified using zero crossings of the first derivative, ( 2) peaks I - VII are identified from these candidate peaks based on their latency and morphology, ( 3) if required, peaks II and IV are identified as points of inflection using zero crossings of the second derivative and ( 4) interpeak troughs are identified before peak latencies and amplitudes are measured. The performance of the algorithm was estimated on a set of 240 normal ABR waveforms recorded using a stimulus intensity of 90 dBnHL. When compared to an expert audiologist, the algorithm correctly identified the major ABR peaks ( I, III and V) in 96 - 98% of the waveforms and the minor ABR peaks ( II, IV, VI and VII) in 45 - 83% of waveforms. Whilst peak II was correctly identified in only 83% and peak IV in 77% of waveforms, it was shown that 5% of the peak II identifications and 31% of the peak IV identifications came as a direct result of allowing these peaks to be found as points of inflection. Copyright (C) 2005 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rise time and duration are two parametric characteristics of the eliciting stimulus frequently used to differentiate among psychophysiological reflexes. The present research varied the duration (study 1) and rise time (study 2) of an intense acoustic stimulus to dissociate cardiac defense and cardiac startle using the eyeblink response as the external criterion of startle. In each study, 100 participants were presented with five white noise stimuli of 105 dB under one of five duration (50, 100, 250, 500, and 1000 ms) or rise time (0, 24, 48, 96, and 240 ms) conditions. Cardiac defense was affected by stimulus duration, present only in the 500- and 1000-ms conditions, but not by stimulus rise time, present in all rise time conditions. Rise time affected blink startle, but did not selectively alter the short latency accelerative component of the heart rate response, thus questioning whether it reflects startle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the outcomes associated with two differing right unilateral (RUL) electroconvulsive therapy (ECT) dosing protocols: 2-3X seizure threshold (2-3X ST) and fixed high dose (FHD) at 353 mC. A retrospective chart review was performed to compare patient outcomes during the implementation of two different dosing protocols: 2-3X ST from October 2000 to May 2001 and FHD from June 2001 to February 2002. A total of 56 patients received ECT under the 2-3X ST protocol, and 46 received ECT under the FHD protocol. In total, 13.6% of patients receiving ECT according to the 2-3X ST protocol received more than 12 ECT, whereas none of the FHD group received more than 12 ECT. The mean number of ECT per treatment course reduced significantly from 7.6 to 5.7 following the switch from the 2-3X ST protocol to the FHD protocol. There were no significant differences between the two groups in the incidence of adverse cognitive effects. ECT practitioners adhered to the 2-3X ST protocol for only 51.8% of ECT courses, with protocol adherence improving to 87% following introduction of the FHD protocol. Although this naturalistic retrospective chart survey had significant methodological limitations, it found that practitioners are more likely to correctly adhere to a fixed dose protocol, therefore, increasing its 'real world' effectiveness in comparison to titrated suprathreshold dosing techniques. The FHD protocol was associated with shorter courses of ECT than the 2-3X ST protocol, with no significant difference between the two protocols in clinically discernable adverse cognitive effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of attention to a lead stimulus and of its sensory properties on modulation of the acoustic blink reflex were investigated. Participants performed a reaction time task cued by an acoustic or a visual lead stimulus. In Experiment 1, half the participants were presented with sustained lead stimuli. For the remainder, the lead stimulus was discrete and consisted of two brief presentations that marked the onset and offset of a stimulus-free interval. In Experiment 2, sustained lead stimuli were presented at a low or high intensity. The attentional demands of the task enhanced blink latency and magnitude modulation during acoustic and visual lead stimuli, with blink modulation being largest at a late point during the lead stimulus. Independent of the attentional effects, blink latency and magnitude modulation were larger during sustained than during discrete acoustic lead stimuli, whereas there was no difference for visual lead stimuli. Increases in the intensity of the lead stimulus enhanced blink modulation regardless of lead stimulus modality. Attention to a lead stimulus and the properties of the lead stimulus appear to have independent effects on blink reflex modulation.