2 resultados para Stability-indicating HPLC
em University of Queensland eSpace - Australia
Resumo:
Objectives: The aim of this study was to investigate the temperature profile of home intravenous (iv) antibiotic reservoirs and the stability of 16 megaunits of benzylpenicillin sodium in 120 mL of sodium chloride 0.9% at constant and variable temperatures. Methods: A Tinytag computerized thermometer recorded temperatures every minute in the home iv antibiotic reservoir pouches of nine patients over a 24 h period. Similar bags containing benzylpenicillin sodium (16 megaunits) were maintained either at a constant 36degreesC, 26degreesC or 21-22degreesC or were worn in a pouch by five healthy volunteers for a 24 h period. Other bags were stored at 3-5degreesC for 10 days. The bags were sampled at timed intervals and benzylpenicillin concentrations assayed by HPLC. Results: Median temperatures recorded in the infusion bags worn by the nine patients were in the range 16.7-34.1degreesC. For infusion bags maintained at 36degreesC, 26degreesC and 21-22degreesC, the concentrations of benzylpenicillin dropped below 90% of the initial concentration at a mean time of 5 h 18 min, 12 h 54 min and 13 h 20 min, respectively, whereas for bags worn by the healthy volunteers the mean time for 10% loss of benzylpenicillin was 9 h 20 min. In contrast, at 3-5degreesC, concentrations of benzylpenicillin only dropped below 90% of the initial concentration at 8 days. Conclusions: Significant temperature-dependent degradation of benzylpenicillin occurs during continuous home iv antibiotic programme infusions, which could result in loss of efficacy.
Resumo:
We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.