155 resultados para Spray water
em University of Queensland eSpace - Australia
Resumo:
The cyclone stickiness test (CST) technique was applied to measure the stickiness temperature and relative humidity of whey, honey, and apple juice powders. A moisture sorption isotherm study was conducted to analyze the surface moisture content of whey powder. The glass transition temperatures of the sample powder were analyzed using differential scanning calorimetry (DSC). The stickiness results of these products were found within 20 degrees C above their surface glass transition temperatures, which is well within the normal temperature range for glass transition in general. The results obtained by the CST technique were found consistent with DSC values.
Resumo:
Stickiness is a major reason that limits the spray drying of various sugar-rich food products. Higher hygroscopicity of amorphous powder, increase in solubility of sugars with temperature, and lower melting point and glass transition temperature, contribute to the stickiness problem. So far, the glass transition temperature has been widely accepted as a best indicator for stickiness. There are various manoeuvres that have been applied to spray dry such products. Some of them are the addition of drying aids, modification of drier design and use of mild drying temperature conditions. This review paper highlights the major research works that deal with the stickiness property of sugar-rich foods.
Resumo:
A semi-empirical linear equation has been developed to optimise the amount of maltodextrin additive (DE 6) required to successfully spray dry a sugar-rich product on the basis of its composition. Based on spray drying experiments, drying index values for individual sugars (sucrose, glucose, frutose) and citric acid were determined, and us;ng these index values an equation for model mixtures of these components was established. This equation has been tested with two sugar-rich natural products, pineapple juice and honey. The relationship was found to be valid for these products.
Resumo:
This study investigates binder distribution in wet granulation and focuses on the nucleation zone, which is the area where the liquid binder and powder surface come into contact and form the initial nuclei. An equipment independent parameter, dimensionless spray flux Psi (a), is defined to characterise the most important process parameters in the nucleation process: solution flowrate, powder flux, and binder drop size. Ex-granulator experiments are used to study the relationship between dimensionless spray flux, process variables and the coverage of binder fluid on the powder surface. Lactose monohydrate powder on a variable speed riffler passed under a flat spray once only. Water and 7% HPC solution at two spray pressures were used as binders. Experiments with red dye and image analysis demonstrate that changes in dimensionless spray flux correlate with a measurable difference in powder surface coverage. Nucleation experiments show that spray flux controls the size and shape of the nuclei size distribution. At low Psi (a), the system operates in the drop controlled regime, where one drop forms one nucleus and the nuclei size distribution is narrow. At higher Psi (a), the powder surface cakes creating a broader size distribution. For controlled nucleation with the narrowest possible size distribution, it is recommended that the dimensionless spray flux be less than 0.1 to be in the drop-controlled regime. (C) 2001 Elsevier Science S.A. All rights reserved.
Resumo:
This paper presents results from field studies carried out during the 1993-1998 Australian cotton (Gossypium hirsutum L.) seasons to monitor off-target droplet movement of endosulfan (6,7,8,9,10,10-hexachloro-1,5,5a,6,9,9a-hexahydro-6,9-methano-2,4,3-benzodioxathiepin 3-oxide) insecticide applied to a commercial cotton crop. Averaged over a wide range of conditions, off-target deposition 500 m downwind of the field boundary was approximately 2% of the field-applied rate with oil-based applications and 1% with water-based applications. Mean airborne drift values recorded 100 m downwind of a single flight line were a third as much with water-based application compared with oil-based application. Calculations using a Gaussian diffusion model and the U.S. Spray Drift Task Force AgDRIFT model produced downwind drift profiles that compared favorably with experimental data. Both models and data indicate that by adopting large droplet placement (LDP) application methods and incorporating crop buffer distances, spray drift can be effectively managed.
Resumo:
Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) were used to detect petroleum-derived spray oils (PDSOs) in citrus seedlings and trees. The NMR spectrum of the phantom containing 10% (v/v) of a nC24 agricultural mineral oil (AMO) showed the resonance of the water protons at delta = 5 ppm, while the resonance of the oil protons at delta = 1.3 to 1.7 ppm. The peak resolution and the chemical shift difference of more than 3.3 ppm between water and oil protons effectively differentiated water and the oil. Chemical shift selective imaging (CSSI) was performed to localize the AMO within the stems of Citrus trifoliata L. seedlings after the application of a 4% (v/v) spray. The chemical shift selective images of the oil were acquired by excitation at delta = 1.5 ppm by averaging over 400 transients in each phase-encoding step. Oil was mainly detected in the outer cortex of stems within 10 d of spray application; some oil was also observed in the inner vascular bundle and pith of the stems at this point. CSSI was also applied to investigate the persistence of oil deposits in sprayed mature Washington navel orange (Citrus x aurantium L.) trees in an orchard. The trees were treated with either fourteen 0.25%, fourteen 0.5%, four 1.75%, or single 7% sprays of a nC23 horticultural mineral oil (HMO) 12 to 16 months before examination of plant tissues by CSSI, and were still showing symptoms of chronic phytotoxicity largely manifested as reduced yield. The oil deposits were detected in stems of sprayed flushes and unsprayed flushes produced 4 to 5 months after the last spray was applied, suggesting a potential movement of the oil via phloem and a correlation of the persistence of oil deposit in plants and the phytotoxicity. The results demonstrate that MRI is an effective method to probe the uptake and localization of PDSOs and other xenobiotics in vivo in plants noninvasively and nondestructively.
Resumo:
This paper presents an analysis of membrane reactor (MR) operation and design for enhanced hydrogen production from the water gas shift (WGS) reaction. It has been established that membrane reactors can enhance an equilibrium limited reaction through product separation. However, the detailed effects of reactor setup, membrane configuration and catalyst volume have yet to be properly analysed for this reaction. This paper investigates new ideas for membrane reactors such as the development of new catalytic films, for improved interaction between the reaction and separation zones. Current membrane reactors utilise a packed bed of catalyst within the membrane tube, utilising a large volume of catalyst to drive reaction. This is still inefficient and provides only limited benefits over conventional WGS reactors. New reactor configurations look to optimise the interactive effects between reaction and separation to provide improved operation. In this paper, thin film catalysts were produced using dip coating and spray coating techniques. This technique produced catalyst coatings with good thickness, though the abrasion strength of the dip coated catalyst was quite low. The catalyst was tested in a packed bed reactor for temperature activity at low temperatures and catalyst activity at varying levels of excess water
Resumo:
Evidence is presented for the existence of a countercurrent flow between water and blood at the respiratory surfaces of the Port Jackson shark gill.
Resumo:
In high-velocity open channel flows, the measurements of air-water flow properties are complicated by the strong interactions between the flow turbulence and the entrained air. In the present study, an advanced signal processing of traditional single- and dual-tip conductivity probe signals is developed to provide further details on the air-water turbulent level, time and length scales. The technique is applied to turbulent open channel flows on a stepped chute conducted in a large-size facility with flow Reynolds numbers ranging from 3.8 E+5 to 7.1 E+5. The air water flow properties presented some basic characteristics that were qualitatively and quantitatively similar to previous skimming flow studies. Some self-similar relationships were observed systematically at both macroscopic and microscopic levels. These included the distributions of void fraction, bubble count rate, interfacial velocity and turbulence level at a macroscopic scale, and the auto- and cross-correlation functions at the microscopic level. New correlation analyses yielded a characterisation of the large eddies advecting the bubbles. Basic results included the integral turbulent length and time scales. The turbulent length scales characterised some measure of the size of large vortical structures advecting air bubbles in the skimming flows, and the data were closely related to the characteristic air-water depth Y90. In the spray region, present results highlighted the existence of an upper spray region for C > 0.95 to 0.97 in which the distributions of droplet chord sizes and integral advection scales presented some marked differences with the rest of the flow.
Resumo:
A novel nucleation apparatus is presented for the production of narrow sized nuclei from various powder and binder liquid combinations. Mono-sized binder liquid droplets are produced by a specially designed mono-disperse droplet generator. The droplet generator is positioned above a conveyor belt, transporting a powder bed through the spray zone of the droplet generator. By nucleating powder on a conveyer belt, the nucleation mechanism is completely separated from all other granulation mechanisms due to the lack of relative motion between primary particles and/or formed nuclei. Nucleation tests were performed using chalcopyrite and limestone powders with water as the binder liquid. At all operating conditions, the formed nuclei were found to originate from multiplicities of drops that merged on the powder bed surface. Investigation of the dynamics of nuclei formation showed that powder-binder liquid combinations with fast penetration dynamics result in less variation in the number of droplets from which nuclei originate. Smaller and more narrowly distributed nuclei were also achieved by increasing powder speed through the spray zone.
Resumo:
Dimensionless spray flux Ψa is a dimensionless group that characterises the three most important variables in liquid dispersion: flowrate, drop size and powder flux through the spray zone. In this paper, the Poisson distribution was used to generate analytical solutions for the proportion of nuclei formed from single drops (fsingle) and the fraction of the powder surface covered by drops (fcovered) as a function of Ψa. Monte-Carlo simulations were performed to simulate the spray zone and investigate how Ψa, fsingle and fcovered are related. The Monte-Carlo data was an excellent match with analytical solutions of fcovered and fsingle as a function of Ψa. At low Ψa, the proportion of the surface covered by drops (fcovered) was equal to Ψa. As Ψa increases, drop overlap becomes more dominant and the powder surface coverage levels off. The proportion of nuclei formed from single drops (fsingle) falls exponentially with increasing Ψa. In the ranges covered, these results were independent of drop size, number of drops, drop size distribution (mono-sized, bimodal and trimodal distributions), and the uniformity of the spray. Experimental data of nuclei size distributions as a function of spray flux were fitted to the analytical solution for fsingle by defining a cutsize for single drop nuclei. The fitted cutsizes followed the spray drop sizes suggesting that the method is robust and that the cutsize does indicate the transition size between single drop and agglomerate nuclei. This demonstrates that the nuclei distribution is determined by the dimensionless spray flux and the fraction of drop controlled nuclei can be calculated analytically in advance.
Resumo:
The concentrations of major, minor and trace metals were measured in water samples collected from five shallow Antarctic lakes (Carezza, Edmonson Point (No 14 and 15a), Inexpressible Island and Tarn Flat) found in Terra Nova Bay (northern Victoria Land, Antarctica) during the Italian Expeditions of 1993-2001. The total concentrations of a large suite of elements (Al, As, Ba, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Gd, K, La, Li, Mg, Mn, Mo, Na, Nd, Ni, Pb, Pr, Rb, Sc, Si, Sr, Ta, Ti, U, V, Y, W, Zn and Zr) were determined using spectroscopic techniques (ICP-AES, GF-AAS and ICP-MS). The results are similar to those obtained for the freshwater lakes of the Larsemann Hills, East Antarctica, and for the McMurdo Dry Valleys. Principal Component Analysis (PCA) and Cluster Analysis (CA) were performed to identify groups of samples with similar characteristics and to find correlations between the variables. The variability observed within the water samples is closely connected to the sea spray input; hence, it is primarily a consequence of geographical and meteorological factors, such as distance from the ocean and time of year. The trace element levels, in particular those of heavy metals, are very low, suggesting an origin from natural sources rather than from anthropogenic contamination.