13 resultados para Spectral method with domain decomposition
em University of Queensland eSpace - Australia
Resumo:
Laurobtusol, a minor metabolite from Laurencia obtusa, had been assigned constitution 1 and relative stereochemistry, 2. However, several stereoisomers of this novel, cyclopropane-containing system 1 have now been synthesized and spectral correspondence between the synthesized isomers and laurobtusol is lacking.
Resumo:
We present an analysis of the free vibration of plates with internal discontinuities due to central cut-outs. A numerical formulation for a basic L-shaped element which is divided into appropriate sub-domains that are dependent upon the location of the cut-out is used as the basic building element. Trial functions formed to satisfy certain boundary conditions are employed to define the transverse deflection of each sub-domain. Mathematical treatments in terms of the continuities in displacement, slope, moment, and higher derivatives between the adjacent sub-domains are enforced at the interconnecting edges. The energy functional results, from the proper assembly of the coupled strain and kinetic energy contributions of each sub-domain, are minimized via the Ritz procedure to extract the vibration frequencies and. mode shapes of the plates. The procedures are demonstrated by considering plates with central cut-outs that are subjected to two types of boundary conditions. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Due to complex field/tissue interactions, high-field magnetic resonance (MR) images suffer significant image distortions that result in compromised diagnostic quality. A new method that attempts to remove these distortions is proposed in this paper and is based on the use of transceiver-phased arrays. The proposed system uses, in the examples presented herein, a shielded four-element transceive-phased array head coil and involves performing two separate scans of the same slice with each scan using different excitations during transmission. By optimizing the amplitudes and phases for each scan, antipodal signal profiles can be obtained, and by combining both the images together, the image distortion can be reduced several fold. A combined hybrid method of moments (MoM)/finite element method (FEM) and finite-difference time-domain (FDTD) technique is proposed and used to elucidate the concept of the new method and to accurately evaluate the electromagnetic field (EMF) in a human head model. In addition, the proposed method is used in conjunction with the generalized auto-calibrating partially parallel acquisitions (GRAPPA) reconstruction technique to enable rapid imaging of the two scans. Simulation results reported herein for 11-T (470-MHz) brain imaging applications show that the new method with GRAPPA reconstruction theoretically results in improved image quality and that the proposed combined hybrid MoM/FEM and FDTD technique is. suitable for high-field magnetic resonance imaging (MRI) numerical analysis.
Resumo:
An important aspect in manufacturing design is the distribution of geometrical tolerances so that an assembly functions with given probability, while minimising the manufacturing cost. This requires a complex search over a multidimensional domain, much of which leads to infeasible solutions and which can have many local minima. As well, Monte-Carlo methods are often required to determine the probability that the assembly functions as designed. This paper describes a genetic algorithm for carrying out this search and successfully applies it to two specific mechanical designs, enabling comparisons of a new statistical tolerancing design method with existing methods. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.
Resumo:
The country-product-dummy (CPD) method, originally proposed in Summers (1973), has recently been revisited in its weighted formulation to handle a variety of data related situations (Rao and Timmer, 2000, 2003; Heravi et al., 2001; Rao, 2001; Aten and Menezes, 2002; Heston and Aten, 2002; Deaton et al., 2004). The CPD method is also increasingly being used in the context of hedonic modelling instead of its original purpose of filling holes in Summers (1973). However, the CPD method is seen, among practitioners, as a black box due to its regression formulation. The main objective of the paper is to establish equivalence of purchasing power parities and international prices derived from the application of the weighted-CPD method with those arising out of the Rao-system for multilateral comparisons. A major implication of this result is that the weighted-CPD method would then be a natural method of aggregation at all levels of aggregation within the context of international comparisons.
Resumo:
Adsorption of supercritical fluids is increasingly carried out to determine the micropore size distribution. This is largely motivated by the advances in the use of supercritical adsorption in high energy applications, such as hydrogen and methane storage in porous media. Experimental data are reported as mass excess versus pressure, and when these data are matched against the theoretical mass excess, significant errors could occur if the void volume used in the calculation of the experimental mass excess is incorrectly determined [Malbrunot, P.; Vidal, D.; Vermesse, J.; Chahine, R.; Bose, T. K. Langmuir 1997, 13, 539]. 1 The incorrect value for the void volume leads to a wrong description of the maximum in the plot of mass excess versus pressure as well as the part of the isotherm over the pressure region where the isotherm is decreasing. Because of this uncertainty in the maximum and the decreasing part of the isotherm, we propose a new method in which the problems associated with this are completely avoided. Our method involves only the relationship between the amount that is introduced into the adsorption cell and the equilibrium pressure. This information of direct experimental data has two distinct advantages. The first is that the data is the raw data without any manipulation (i.e., involving further calculations), and the second one is that this relationship always monotonically increases with pressure. We will illustrate this new method with the adsorption data of methane in a commercial sample of activated carbon.
Resumo:
Recently the Balanced method was introduced as a class of quasi-implicit methods for solving stiff stochastic differential equations. We examine asymptotic and mean-square stability for several implementations of the Balanced method and give a generalized result for the mean-square stability region of any Balanced method. We also investigate the optimal implementation of the Balanced method with respect to strong convergence.
Resumo:
Although the aim of conservation planning is the persistence of biodiversity, current methods trade-off ecological realism at a species level in favour of including multiple species and landscape features. For conservation planning to be relevant, the impact of landscape configuration on population processes and the viability of species needs to be considered. We present a novel method for selecting reserve systems that maximize persistence across multiple species, subject to a conservation budget. We use a spatially explicit metapopulation model to estimate extinction risk, a function of the ecology of the species and the amount, quality and configuration of habitat. We compare our new method with more traditional, area-based reserve selection methods, using a ten-species case study, and find that the expected loss of species is reduced 20-fold. Unlike previous methods, we avoid designating arbitrary weightings between reserve size and configuration; rather, our method is based on population processes and is grounded in ecological theory.
Resumo:
Plant litter and fine roots are important in maintaining soil organic carbon (C) levels as well as for nutrient cycling. The decomposition of surface-placed litter and fine roots of wheat ( Triticum aestivum ), lucerne ( Medicago sativa ), buffel grass ( Cenchrus ciliaris ), and mulga ( Acacia aneura ), placed at 10-cm and 30-cm depths, was studied in the field in a Rhodic Paleustalf. After 2 years, = 60% of mulga roots and twigs remained undecomposed. The rate of decomposition varied from 4.2 year -1 for wheat roots to 0.22 year -1 for mulga twigs, which was significantly correlated with the lignin concentration of both tops and roots. Aryl+O-aryl C concentration, as measured by 13 C nuclear magnetic resonance spectroscopy, was also significantly correlated with the decomposition parameters, although with a lower R 2 value than the lignin concentration. Thus, lignin concentration provides a good predictor of litter and fine root decomposition in the field.
Resumo:
Background: In 1992, Frisch et al (Psychol Assess. 1992;4:92- 10 1) developed the Quality of Life Inventory (QOLI) to measure the concept of quality of life (QOL) because it has long been thought to be related to both physical and emotional well-being. However, the psychometric properties of the QOLI in clinical populations are still in debate. The present study examined the factor structure of QOLI and reported its validity and reliability in a clinical sample. Method: Two hundred seventeen patients with anxiety and depressive disorders completed the QOLI and additional questionnaires measuring symptoms (Zung Self-rating Depression Scale, Beck Anxiety Inventory, Fear Questionnaire, Depression Anxiety Stress Scale-Stress) and subjective well-being (Satisfaction With Life Scale) were also used. Results: Exploratory factor analysis via the principal components method, with oblique rotation, revealed a 2-factor structure that accounted for 42.73% of the total variance, and a subsequent confirmatory factor analysis suggested a moderate fit of the data to this model. The 2 factors appeared to describe self-oriented QOL and externally oriented QOL. The Cronbach alpha coefficients were 0.85 for the overall QOLI score, 0.81 for the first factor, and 0.75 for the second factor. Conclusion: Consistent evidence was also found to support the concurrent, discriminant, predictive, and criterion-related validity of the QOLI. (c) 2006 Elsevier Inc. All rights reserved.
Resumo:
Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.