73 resultados para Soyland Power Cooperative

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power system real time security assessment is one of the fundamental modules of the electricity markets. Typically, when a contingency occurs, it is required that security assessment and enhancement module shall be ready for action within about 20 minutes’ time to meet the real time requirement. The recent California black out again highlighted the importance of system security. This paper proposed an approach for power system security assessment and enhancement based on the information provided from the pre-defined system parameter space. The proposed scheme opens up an efficient way for real time security assessment and enhancement in a competitive electricity market for single contingency case

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The BR algorithm is a novel and efficient method to find all eigenvalues of upper Hessenberg matrices and has never been applied to eigenanalysis for power system small signal stability. This paper analyzes differences between the BR and the QR algorithms with performance comparison in terms of CPU time based on stopping criteria and storage requirement. The BR algorithm utilizes accelerating strategies to improve its performance when computing eigenvalues of narrowly banded, nearly tridiagonal upper Hessenberg matrices. These strategies significantly reduce the computation time at a reasonable level of precision. Compared with the QR algorithm, the BR algorithm requires fewer iteration steps and less storage space without depriving of appropriate precision in solving eigenvalue problems of large-scale power systems. Numerical examples demonstrate the efficiency of the BR algorithm in pursuing eigenanalysis tasks of 39-, 68-, 115-, 300-, and 600-bus systems. Experiment results suggest that the BR algorithm is a more efficient algorithm for large-scale power system small signal stability eigenanalysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The linear relationship between work accomplished (W-lim) and time to exhaustion (t(lim)) can be described by the equation: W-lim = a + CP.t(lim). Critical power (CP) is the slope of this line and is thought to represent a maximum rate of ATP synthesis without exhaustion, presumably an inherent characteristic of the aerobic energy system. The present investigation determined whether the choice of predictive tests would elicit significant differences in the estimated CP. Ten female physical education students completed, in random order and on consecutive days, five art-out predictive tests at preselected constant-power outputs. Predictive tests were performed on an electrically-braked cycle ergometer and power loadings were individually chosen so as to induce fatigue within approximately 1-10 mins. CP was derived by fitting the linear W-lim-t(lim) regression and calculated three ways: 1) using the first, third and fifth W-lim-t(lim) coordinates (I-135), 2) using coordinates from the three highest power outputs (I-123; mean t(lim) = 68-193 s) and 3) using coordinates from the lowest power outputs (I-345; mean t(lim) = 193-485 s). Repeated measures ANOVA revealed that CPI123 (201.0 +/- 37.9W) > CPI135 (176.1 +/- 27.6W) > CPI345 (164.0 +/- 22.8W) (P < 0.05). When the three sets of data were used to fit the hyperbolic Power-t(lim) regression, statistically significant differences between each CP were also found (P < 0.05). The shorter the predictive trials, the greater the slope of the W-lim-t(lim) regression; possibly because of the greater influence of 'aerobic inertia' on these trials. This may explain why CP has failed to represent a maximal, sustainable work rate. The present findings suggest that if CP is to represent the highest power output that an individual can maintain for a very long time without fatigue then CP should be calculated over a range of predictive tests in which the influence of aerobic inertia is minimised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the effective diagnostic technique(s) for assessing the condition of insulation in aged power transformers. A number of electrical, mechanical and chemical techniques were investigated. Many of these techniques are already used by the utility engineers and two comparatively new techniques are proposed in this paper. Results showing the effectiveness of these diagnostics are presented and correlation between the techniques are also presented. Finally, merits and suitability of different techniques are discussed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study investigated the behaviors and interactions of children in structured and unstructured groups as they worked together on a 6-week social studies activity each term for 3 school terms. Two hundred and twelve children in Grade 1 and 184 children in Grade 3 participated in the study. Stratified random assignment occurred so that each gender-balanced group consisted of 1 high-, 2 medium-, and 1 low-ability student. The results show that the children in the structured groups were consistently more cooperative and they provided more elaborated and nonelaborated help than did their peers in the unstructured groups. The children in the structured groups in Grade 3 obtained higher reading and learning outcome scores than their peers in the unstructured groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to effectively suppress the noise radiation from large electrical power transformers, both the structure-borne and air-borne sound fields need to be characterised. The characterisation can be made either from theoretical predictions or by in-situ measurements. This paper presents the study of the sound radiation from a large power transformer in a substation. The radiation pattern can be predicted from the measured acceleration distribution and the predicted value is not affected by other noise sources. Alternatively, the farfield sound pressure level can be predicted from the sound pressure level measured at NEMA locations. Both the near- and far-field power radiation can be in-situ measured using the sound intensity technique. It is shown that both the vibration of a transformer tank wall and the radiated noise consist of a series of tonal components mainly at the first few harmonic frequencies of 100 Hz. Also, the neglect of the noise radiation from the transformer (top and bottom) lids does not affects the accuracy of the transformer radiation characterisation. (C) 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors conducted a 1-year investigation of whether children, who had been trained in the previous school gear to cooperate, were able to use the skills they had been taught in reconstituted groups without additional training. Sixty-four 4th graders, who had participated in training in cooperative group behaviors in the previous gear, were assigned to the trained condition; 84 4th graders, who had not received any training, were assigned to the untrained condition. The children worked in mixed-ability (high, medium, low) gender-balanced groups (2 boys, 2 girls). Results indicate that the children in the trained groups were consistently more cooperative and helpful than their peers in the untrained groups, although they had not received refresher training in cooperative group behaviors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is devoted to the problems of finding the load flow feasibility, saddle node, and Hopf bifurcation boundaries in the space of power system parameters. The first part contains a review of the existing relevant approaches including not-so-well-known contributions from Russia. The second part presents a new robust method for finding the power system load flow feasibility boundary on the plane defined by any three vectors of dependent variables (nodal voltages), called the Delta plane. The method exploits some quadratic and linear properties of the load now equations and state matrices written in rectangular coordinates. An advantage of the method is that it does not require an iterative solution of nonlinear equations (except the eigenvalue problem). In addition to benefits for visualization, the method is a useful tool for topological studies of power system multiple solution structures and stability domains. Although the power system application is developed, the method can be equally efficient for any quadratic algebraic problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effects of four high-intensity interval-training (HIT) sessions performed over 2 weeks on peak volume of oxygen uptake (VO2peak), the first and second ventilatory thresholds (UT VT2) and peak power output (PPO) in highly trained cyclists. Fourteen highly trained male cyclists (VO2peak = 67.5 +/- 3.7 ml . kg(-1) . min(-1)) performed a ramped cycle test to determine VO2peak VT1 VT2, and PPO. Subjects were divided equally into a HIT group and a control group. The HIT group performed four HIT sessions (20 x 60 s at PPO, 120 s recovery); the V-02peak test was repeated <I wk after the HIT program. Control subjects maintained their regular training program and were reassessed under the same timeline. There was no change in V0(2peak) for either group; however, the HIT group showed a significantly greater increase in VT1, (+22% vs. -3%), VT2 (+15% vs. -1%), and PPO (+4.3 vs. -.4%) compared to controls (all P <.05). This study has demonstrated that HIT can improve VT1, VT2,, and PPO, following only four HIT sessions in already highly trained cyclists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose - Unaccustomed strenuous physical exertion can trigger myocardial infarction, but little is known about the mechanisms precipitating subarachnoid hemorrhage (SAH). Methods - We identified all cases of first-ever SAH among the combined populations (2.8 million) of 4 urban centers in Australia and New Zealand. Information on the type, time, and intensity of exposures in the 26 hours before the onset of SAH was ascertained by structured interviews. We used the case-crossover technique to assess the risk of SAH associated with transient exposures of moderate to extreme physical exertion, heavy cigarette smoking, and binge alcohol consumption. Results - We registered 432 first-ever cases of SAH (62% women; mean age, 56.5 years). A definite time of onset of SAH was established for 393 patients (91%), and information on the levels of physical activity in the preceding 26 hours was obtained in 338 ( 78%). Of these patients, 19% engaged in moderate to extreme exertion (greater than or equal to5 metabolic equivalents) in the 2 hours before SAH, which was associated with a tripling in the risk of SAH (odds ratio [OR], 2.7; 95% CI, 1.6 to 4.6). There was no evidence of any association between heavy cigarette smoking or binge drinking and risk of SAH in the subsequent 2 hours ( OR, 1.1; 95% CI, 0.4 to 3.7; and OR, 0.41; 95% CI, -infinity to 5.3). Habitual exercise did not appear to alter the risk of SAH associated with moderate to extreme exertion. Conclusions - Moderate to extreme physical exertion tripled the risk of SAH, but there was no association between transient heavy smoking or binge drinking and risk of SAH. These data suggest that heavy physical activity may trigger SAH.