35 resultados para Solar energy, solar collector, solar heater, low cost

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An integrated anaerobic-aerobic treatment system of sulphate-laden wastewater was proposed here to achieve low sludge production, low energy consumption and effective sulphide control. Before integrating the whole system, the feasibility of autotrophic denitrification utilising dissolved sulphide produced during anaerobic treatment of sulphate rich wastewater was studied here. An upflow anaerobic sludge blanket reactor was operated to treat sulphate-rich synthetic wastewater (TOC = 100 mg/L and sulphate = 500 mg/L) and its effluent with dissolved sulphide and external nitrate solution were fed into an anoxic biofilter. The anaerobic reactor was able to remove 77-85% of TOC at HRT of 3 h and produce 70-90 mg S/L sulphide in dissolved form for the subsequent denitrification. The performance of anoxic reactor was stable, and the anoxic reactor could remove 30 mg N/L nitrate at HRT of 2 h through autotrophic denitrification. Furthermore, sulphur balance for the anoxic filter showed that more than 90% of the removed sulphide was actually oxidised into sulphate, thereby there was no accumulation of sulphur particles in the filter bed. The net sludge productions were approximately 0.15 to 0.18 g VSS/g COD in the anaerobic reactor and 0.22 to 0.31 g VSS/g NO3--N in the anoxic reactor. The findings in this study will be helpful in developing the integrated treatment system to achieve low-cost excess sludge minimisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Swinfen Charitable Trust was established in 1998 with the aim of helping the poor, sick and disabled in the developing world. It does this by setting up simple telemedicine links based on email to support doctors in isolated hospitals. The first telemedicine link was established to support the lone orthopaedic surgeon at the Centre for the Rehabilitation of the Paralysed (CRP) in Savar, near Dhaka in Bangladesh, in July 1999. An evaluation of the 27 referrals made during the first year of operation showed that the telemedical advice had been useful and cost-effective. Based on the success of the Bangladesh project, the Swinfen Charitable Trust supplied: digital cameras and tripods to more hospitals in other developing countries. These are Patan Hospital in Nepal (March 2000), Gizo Hospital in the Solomon Islands (March 2000), Helena Goldie Hospital: on New Georgia in the Solomon Islands (September 2000) and LAMB Hospital in Bangladesh (September 2000).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In July 1999, the Swinfen Charitable Trust in the UK established a telemedicine link in Bangladesh, between the Centre for the Rehabilitation of the Paralysed (CRP) in Dhaka and medical consultants abroad. This low-cost telemedicine system used a digital camera to capture still images, which were then transmitted by email. During the first 12 months, 27 telemedicine referrals were made. The following specialties were consulted: neurology (44%), orthopaedics (40%), rheumatology (8%), nephrology (4%) and paediatrics (4%). Initial email replies were received at the CRP within a day of referral in 70% of cases and within thee days in 100%, which shows that store-and-forward telemedicine can be both fast and reliable. Telemedicine consultation was complete within three days in 14 cases (52%) and within three weeks in 24 cases (89%). Referral was judged to be beneficial in 24 cases (89%), the benefits including establishment of the diagnosis, the provision of reassurance to the patient and referring doctor, and a change of management. Four patients (15% of the total) and their families were spared the considerable expense and unnecessary stress of travelling abroad for a second opinion, and the savings from this alone outweighed the set-up and running costs in Bangladesh. The latter are limited to an email account with an Internet service provider and the local-rate telephone call charges from the CRP. This successful telemedicine system is a model for further telemedicine projects in the developing world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-cost UHF-band p-i-n diodes are used to develop high-performance L-band series and parallel switches. To stop the rectification of large RF, signals, the diodes are biased at a large reverse-bias voltage. Parasitic elements of the diodes are tuned out using LC circuits in biasing circuits without increasing the size of the switches. (C) 2002 John Wiley Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited available hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Teledermatology can provide both accurate and reliable specialist care at a distance. This article reviews current data on the quality of care that teledermatology provides, as well as the societal cost benefits involved in the implementation of the technique. Teledermatology is most suited to patients unable to access specialist. services for geographical or social reasons. Patients are generally satisfied with the overall care that teledermatology provides. Real-time teledermatology is more expensive than conventional care for health services. However, significant savings can be expected from the patient's perspective due to reduced travel. Appropriate patient selection, improved technology and adequate clinical workloads may improve both the quality and cost effectiveness of this service.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Swinfen Charitable Trust has used email for some years as a low-cost telemedicine medium to provide consultant support for doctors in developing countries. A scalable, automatic message-routing system was constructed which automates many of the tasks involved in message handling. During the first 12 months of its use, 1510 messages were processed automatically. There were 128 referrals from 18 hospitals in nine countries. Of these 128 queries, 89 (70%) were replied to within 72 h; the median delay was 1.1 day. The 39 unanswered queries were sent to backup specialists for reply and 36 of them (92%) were replied to within 72 h. In the remaining three cases, a second-line (backup) specialist was required. The referrals were handled by 54 volunteer specialists from a panel of over 70. Two system operators, located 10 time zones apart, managed the system. The median time from receipt of a new referral to its allocation to a specialist was 0.2 days (interquartile range, IQR, 0.1-0.8). The median interval between receipt of a new referral and first reply was 2.6 days (IQR 0.8-5.9). Automatic message handling solves many of the problems of manual email telemedicine systems and represents a potentially scalable way of doing low-cost telemedicine in the developing world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the feasibility of a low-cost, store-and-forward teledermatology service for general practitioners (GPs) in regional Queensland. Digital pictures and a brief case history were transmitted by email. A service coordinator carried out quality control checks and then forwarded these email messages to a consultant dermatologist. On receiving a clinical response from the dermatologist, the service coordinator returned the message to the referring GP. The aim was to provide advice to rural Gps within one working day. Over six months, 63 referrals were processed by the teledermatology service, covering a wide range of dermatological conditions. In the majority of cases the referring doctors were able to treat the condition after receipt of email advice from the dermatologist; however, in 10 cases (16%) additional images or biopsy results were requested because image quality was inadequate. The average time between a referral being received and clinical advice being provided to the referring GPs was 46 hours. The number of referrals in the present study, 1.05 per month per site, was similar to that reported in other primary care studies. While the use of low-cost digital cameras and public email is feasible, there may be other issues, for example remuneration, which will militate against the widespread introduction of primary care teledermatology in Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the design rationale and basic workings of a low-cost, easy-to-use power system simulator developed to support investigations into human interface design for a hydropower plant. The power system simulator is based on three important components: models of power system components, a data repository, and human interface elements. Dynamic Data Exchange (DDE) allows simulator components to communicate with each other within the simulator. To construct the modules of the simulator we have combined the advantages of commercial software such as Matlab/Simulink, ActiveX Control, Visual Basic and Excel and integrated them in the simulator. An important advantage of our approach is that further components of the simulator now can be developed independently. An initial assessment of the simulator indicates it is fit for intended purpose.