9 resultados para Silicone elastomer

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Investment casting is often used to produce fully functional prototype components from sacrificial patterns. These patterns (prototypes) may be made using specialized rapid prototyping techniques such as stereolithography or three-dimensional printing. When multiple functional prototypes are required, interim tools for making wax patterns are employed. The objective of this research work was to determine the precision and accuracy of wax patterns produced using several prototype tools. Linear contraction was used to determine the accuracy as a function of the wax injection parameters used in low-pressure injection moulding. Wax patterns were produced using polyurethane and silicone rubber tools. It has been shown that the accuracy of patterns from both tools is similar. However, silicone tools produce patterns with much higher contraction than those produced by polyurethane tools. Unconstrained patterns dimensions contracted as much as 3.44 +/- 0.40 per cent and 1.70 +/- 0.60 per cent for silicone and polyurethane tools respectively. The constrained dimensions contracted by 2.20 +/- 0.20 per cent in the case of silicone tools and 1.40 +/- 0.20 per cent in the case of polyurethane tools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The long-term biostability of a novel thermoplastic polyurethane elastomer (Elast-Eon(TM) 2 80A) synthesized using poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols has been studied using an in vivo ovine model. The material's biostability was compared with that of three commercially available control materials, Pellethane(R) 2363-80A, Pellethane(R) 2363-55D and Bionate(R) 55D, after subcutaneous implantation of strained compression moulded flat sheet dumbbells in sheep for periods ranging from 3 to 24 months. Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were used to assess changes in the surface chemical structure and morphology of the materials. Gel permeation chromatography, differential scanning calorimetry and tensile testing were used to examine changes in bulk characteristics of the materials. The results showed that the biostability of the soft flexible PDMS-based test polyurethane was significantly better than the control material of similar softness, Pellethane(R) 80A, and as good as or better than both of the harder commercially available negative control polyurethanes. Pellethane(R) 55D and Bionate(R) 55D. Changes observed in the surface of the Pellethane(R) materials were consistent with oxidation of the aliphatic polyether soft segment and hydrolysis of the urethane bonds joining hard to soft segment with degradation in Pellethane(R) 80A significantly more severe than that observed in Pellethane(R) 55D. Very minor changes were seen on the surfaces of the Elast-Eon(TM) 2 80A and Bionate(R) 55D materials. There was a general trend of molecular weight decreasing with time across all polymers and the molecular weights of all materials decreased at a similar relative rate. The polydispersity ratio, M-w/M-n, increased with time for all materials. Tensile tests indicated that UTS increased in Elast-Eon(TM) 2 80A and Bionate(R) 55D following implantation under strained conditions. However, ultimate strain decreased and elastic modulus increased in the explanted specimens of all three materials when compared with their unimplanted unstrained counterparts. The results indicate that a soft, flexible PDMS-based polyurethane synthesized using 20% PHMO and 80% PDMS macrodiols has excellent long-term biostability compared with commercially available polyurethanes. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: How a scar is managed postoperatively influences Its cosmetic outcome. After Suture removal, scars are susceptible to skin tension, which may be the trigger for hypertrophic scarring. Paper tape to support the scar may reduce multidirectional forces and prevent hypertrophic scarring. Methods: Seventy patients who had under gone cesarean section at the Royal Brisbane and Women's Hospital were randomized to treatment and control groups. Patients in the control group received no postoperative intervention. Patients in the treatment group applied paper tape to their scars for 12 weeks. Scars were assessed at 6 weeks, 12 weeks, and 6 months after surgery using Ultrasound to measure intradermal scar volume. Scars were also assessed using the International Clinical Recommendations. Results: Paper tape significantly decreased scar volume by a mean of 0.16 cm(3), (95 percent confidence Interval, 0.00 to 0.29 cm(3)) At 12 weeks after surgery, 41 percent of the control group developed hypertrophic scars compared with none in the treatment group (exact test, p = 0.003). In the treatment group, one patient developed a hypertrophic scar and four developed stretched scars only after the tape was removed. The odds of developing a hypertrophic scar were 13.6 times greater in the control than in the treatment group (95 percent confidence interval, 3.6 to 66.9). Of the 70 patients randomized, 39 completed the study. Four patients in the treatment group developed a localized red rash beneath the tape. These reactions were minor and transient and resolved without medical intervention. Conclusions: The development of hypertrophic and stretched scars in the treatment group only after the tape was removed suggests that tension acting on a scar is die trigger for hypertrophic scarring. Paper tape is likely to be an effective modality for the prevention of hypertrophic scarring through its ability to eliminate scar tension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To compare the pubovaginal sling and transurethral Macroplastique in the treatment of female stress urinary incontinence (SUI) and intrinsic sphincter deficiency (ISD). Design A prospective randomised controlled trial comparing two surgical treatments for SUI and ISD. Setting Tertiary referral urogynaecology unit in Australia. Population Women with SUI and ISD who were suitable for either surgical technique. Methods Forty-five women with SUI and ISD were randomly allocated the pubovaginal sling (n = 22) or transurethral Macroplastique (n = 23). Subjective and objective success rates, patient satisfaction and cost measurements at six months and one year following surgery were the primary outcome measures. A telephone questionnaire survey was performed at a mean follow up period of 62 months (43-71). Main outcome measure Comparison of success rates, complications and costs. Results The symptomatic and patient satisfaction success rates were similar following the sling and Macroplastique with the objective success rate being significantly greater (P < 0.001) following the sling (81% vs 9%). Macroplastique had significantly lower morbidity but was more expensive than the sling (P < 0.001). Response rate at 62 months follow up was 60% in both groups with the sling group reporting better continence success (69% vs 21%) and satisfaction rates (69% vs 29%, P = 0.057). Conclusions The pubovaginal sling was more effective and economical than transurethral Macroplastique for the treatment of SUI and ISD. However, transurethral Macroplastique remains an appropriate treatment in selected cases of SUI and ISD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We are using polymer templates to grow artificial artery grafts in vivo for the replacement of diseased blood vessels. We have previously shown that adhesion of macrophages to the template starts the graft formation. We present a study of the mechanics of macrophage adhesion to these templates on a single cell and single bond level with optical tweezers. For whole cells, in vitro cell adhesion densities decreased significantly from polymer templates polyethylene to silicone to Tygon (167, 135, and 65 cells/mm(2)). These cell densities were correlated with the graft formation success rate (50%, 25%, and 0%). Single-bond rupture forces at a loading rate of 450 pN/s were quantified by adhesion of trapped 2-mm spheres to macrophages. Rupture force distributions were dominated by nonspecific adhesion (forces, < 40 pN). On polystyrene, preadsorption of fibronectin or presence of serum proteins in the cell medium significantly enhanced adhesion strength from a mean rupture force of 20 pN to 28 pN or 33 pN, respectively. The enhancement of adhesion by fibronectin and serum is additive (mean rupture force of 43 pN). The fraction of specific binding forces in the presence of serum was similar for polystyrene and polymethyl-methacrylate, but specific binding forces were not observed for silica. Again, we found correlation to in vivo experiments, where the density of adherent cells is higher on polystyrene than on silica templates, and can be further enhanced by fibronectin adsorption. These findings show that in vitro adhesion testing can be used for template optimization and to substitute for in-vivo experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polymeric microdrops of low viscosity, elastic fluids have been generated in T-shaped microfluidic devices using a cross-flow shear-induced drop generation process. Dilute (c/c* similar to 0.5) aqueous solutions of polyethylene oxide (PEO) of various molecular weights (3 x 10(5) -2 x 10(6) g/mol) were used as the drop phase fluids whilst silicone oils (5 mPa s

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The viscoelastic behaviour of a range of polyurethane thermoplastic elastomer montmorillonite nanocomposites has been studied using a nanohardness tester. For softer Shore hardness 80A materials, the introduction of the organo-clay increased the creep strain obtained while the nano-indentor was held at constant load. The increase in creep strain was greatest for materials containing an organo-clay modified with a more hydrophilic quaternary alkylammonium surfactant and with higher loadings of the hydrophilic organo-clay. This suggested the effect might be due to a plasticising effect of the excess surfactant. For the harder Shore hardness 55D materials, the addition of the organo-clays produced only a small decrease in the creep strain, probably due to the interconnected hard domains in this material.