51 resultados para Sculpture, Norman

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alcove to deck, as seen from garden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alcove to deck, with timber handrail in foreground.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alcove to deck, as seen from garden.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contents: Introduction SUSAN COCHRANE National Gallery of Australia, Canberra WALLY CARUANA National Museum of Australia, Canberra DAVID KAUS Museum and Art Gallery of the Northern Territory, Darwin MARGIE WEST Art Gallery of New South Wales, Sydney HETTI PERKINS AND KEN WATSON Museum of Contemporary Art, Sydney BERNICE MURPHY Queensland Art Gallery, Brisbane MARCO NEALE Queensland Museum, Brisbane RICHARD ROBINS National Gallery of Victoria, Melbourne JUDITH RYAN Museum Victoria, Melbourne GAYE SCULTHORPE Tasmanian Museum and Art Gallery, Hobart KIM AKERMAN AND DAVID HANSEN Art Gallery of Western Australia, Perth MICHAEL O'FERRALL AND BRENDA L. CROFT Western Australian Museum, Perth ROSS CHADWICK AND MANCE LOFGREN Art Gallery of South Australia, Adelaide JANE HYLTON South Australian Museum, Adelaide PHILIP A. CLARKE List of Plates Bibliography Editor's Acknowledgments Contributors Index

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface passivation of PbS nanocrystals (NC), resulting in strong photoluminescence, can be achieved by the introduction of CdS precursors. The role of CdS in the surface passivation of PbS NCs is uncertain, as the crystalline structure of CdS and PbS are different, which should impede effective epitaxial overgrowth. Absorption spectroscopy is used to show that the CdS precursors strongly interact with the PbS NC surface. Electron microscopy reveals that the introduction of CdS precursors results in an increased particle size, consistent with overcoating. However, we also find the process to be highly non-uniform. Nevertheless, evidence for epitaxial growth is found, suggesting that effective surface passivation may be possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optically transparent, mesostructured titanium dioxide thin films were fabricated using an amphiphilic poly(alkylene oxide) block copolymer template in combination with retarded hydrolysis of a titanium isopropoxide precursor. Prior to calcination, the films displayed a stable hexagonal mesophase and high refractive indices (1.5 to 1.6) relative to mesostructured silica (1.43). After calcination, the hexagonal mesophase was retained with surface areas >300 m2 g-1. The dye Rhodamine 6G (commonly used as a laser dye) was incorporated into the copolymer micelle during the templating process. In this way, novel dye-doped mesostructured titanium dioxide films were synthesised. The copolymer not only directs the film structure, but also provides a solubilizing environment suitable for sustaining a high monomer-to-aggregate ratio at elevated dye concentrations. The dye-doped films displayed optical thresholdlike behaviour characteristic of amplified spontaneous emission. Soft lithography was successfully applied to micropattern the dye-doped films. These results pave the way for the fabrication and demonstration of novel microlaser structures and other active optical structures. This new, high-refractive index, mesostructured, dye-doped material could also find applications in areas such as optical coatings, displays and integrated photonic devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To test the acceptability of screening and to identify modifiable risk factors for abdominal aortic aneurysm (AAA) in men. Design: A trial of ultrasound screening for AAA in a population-based random sample of men aged 65-83 years, and a cross-sectional case-control comparison of men in the same sample. Participants: 12203 men who had an ultrasound examination of their abdominal aorta, and completed a questionnaire covering demographic, behavioural and medical factors. Main outcome measures: Prevalence of AAA, and independent associations of AAA with demographic, medical and lifestyle factors. Results: Invitations to screening produced a corrected response of 70.5%. The prevalence of AAAs (> 30 mm) rose from 4.8% in men aged 65-69 years to 10.8% in those aged 80-83 years. The overall prevalence of large (> 50 mm) aneurysms was 0.69%. In a multivariate logistic model Mediterranean-born men had a 40% lower risk of AAA (> 30 mm) compared with men born in Australia (odds ratio [OR], 0.6; 95% CI, 0.4-0.8), while ex-smokers had a significantly increased risk of AAA (OR, 2.3; 95% CI, 1.9-2.8), and current smokers had even higher risks. AAA was significantly associated with established coronary and peripheral arterial disease and a waist:hip ratio greater than 0.9; men who regularly undertook vigorous exercise had a lower risk (OR, 0.8; 95% CI, 0.7-1.0). Conclusion: Ultrasound screening for AAA is acceptable to men in the likely target population. AAA shares some but not all of the risk factors for occlusive vascular disease, but the scope for primary prevention of AAA in later life is limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives-To investigate the feasibility of selective screening for abdominal aortic aneurysm (AAA) based on identification of a target group of manageable size defined by risk factors for AAA. Setting-Male residents of Perth, Western Australia, aged 65-83 years, who participated in a randomised controlled trial of ultrasound screening for AAA. Methods-Eligible men were identified from the electoral roll and invited to attend a screening clinic. Those who attended completed a questionnaire, had a limited physical examination, and underwent an ultrasound examination to identify the maximum diameter of the infrarenal aorta. Data on risk factors collected from the first 8995 men seen were used to calculate a multivariate risk score for the remaining 2755 men who were screened. Gentiles of the risk score were used to define potential target groups for screening and the sensitivity and specificity of each of these selective screening strategies were calculated. We repeated the calculation separately for AAAs of at least 30 mm, 40 mm, and 50 mm in diameter. Results-We found that screening half of the male population aged 65-83 years would find approximately 75% of AAAs, regardless of their size, whereas screening only current smokers in this population would find approximately 20% of AAAs. Conclusions-Selective screening for AAA using easily recognisable risk factors is feasible but is not worthwhile as approximately 25% of clinically significant cases would be missed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Increased life expectancy in men during the last thirty years is largely due to the decrease in mortality from cardiovascular disease in the age group 29-69 yr. This change has resulted in a change in the disease profile of the population with conditions such as aneurysm of the abdominal aorta (AAA) becoming more prevalent. The advent of endoluminal treatment for AAA has encouraged prophylactic intervention and fuelled the argument to screen for the disease. The feasibility of inserting an endoluminal graft is dependent on the morphology and growth characteristics of the aneurysm. This study used data from a randomized controlled trial of ultrasound screening for AAA in men aged 65-83 yr in Western Australia for the purpose of determining the norms of the living anatomy in the pressurized infrarenal aorta. Aims. To examine (1) the diameters of the infra-renal aorta in aneurysmal and non-aneurysmal cases, (2) the implications for treatment modalities, with particular reference to endoluminal grafting, which is most dependent on normal and aneurysmal morphology, and (3) any evidence to support the notion that northern Europeans are predisposed to aneurysmal disease. Methods. Using ultrasound, a randomized control trial was established in Western Australia to assess the value of a screening program in males aged 65-83 yr, The infra-renal aorta was defined as aneurysmal if the maximum diameter was 30 mm or more. Aortic diameter was modelled both as a continuous tin mm) and as a binary outcome variable, for those men who had an infra-renal diameter of 30 mm or more. ANOVA and linear regression were used for modelling aortic diameter as a continuum, while chi-square analysis and logistic regression were used in comparing men with and without the diagnosis of AAA. Findings. By December 1998, of 19.583 men had been invited to undergo ultrasound screening for AAA, 12.203 accepted the invitation (corrected response fraction 70.8%). The prevalence of AAA increased with age from 4.8% at 65 yr to 10.8% at 80 yr (chi (2) = 77.9, df = 3, P<0.001). The median (IQR) diameter for the non-aneurysmal group was 21.4 mm (3.3 mm) and there was an increase (<chi>(2) = 76.0, df = 1, P<0.001) in the diameter of the infra-renal aorta with age. Since 27 mm is the 95th centile for the non-aneurysmal infra-renal aorta, a diameter of 30 mm or more is justified as defining an aneurysm. The risk of AAA was higher in men of Australian (OR = 1.0) and northern European origin (OR = 1.0, 95%CL: 0.9. 1.2) compared with those of Mediterranean origin (OR = 0.5, 99%CL: 0.4, 0.7). Conclusion. Although screening has not yet been shown to reduce mortality from AAA. these population-based data assist the understanding of aneurysmal disease and the further development and use of endoluminal grafts for this condition. (C) 2001 Published by Elsevier Science Ltd on behalf of The International Society for Cardiovascular Surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background We sought to test, in men Undergoing ultrasound screening for abdominal aortic aneurysms (AAA) in Western Australia, clinical impressions that the prevalence of AAA is high in Dutch migrants and low in migrants from Mediterranean countries. Methods In a. population-based trial, men undergoing screening for AAA completed a questionnaire covering their place of birth, smoking habits and consumption of alcohol, meat, fish, salt and milk. We examined the variation by place of birth in the mean, median, 95th and 99th centiles of infrarenal aortic diameter and the prevalences of AAA defined by criteria of 30 mm, 50 mm and by the 95th and 99th centiles, in men born in Australia, of aortic diameter adjusted for height. Findings Overall, 12 203 (70.5%) of the 19 583 men took up the invitation to undergo ultrasound screening. The prevalence of AAA defined by absolute diameter was higher than average in men born in The Netherlands or Scotland (more of whom had ever smoked or smoked currently) and lower in men of Mediterranean origin (more of whom drank alcohol currently). There were no consistent relationships with simple dietary: data. Correction of aortic diameter for height eliminated the significant heterogeneity in prevalence of large AAA, although a threefold variation in prevalence of AAA exceeding the 95th centile of height-adjusted diameter in Australian men persisted. Interpretation In our cohort of men, which is subject to both 'healthy migrant' and 'survivor' effects, if it exists at all, any 'Mediterranean paradox' for AAA is more modest than that for coronary disease.