102 resultados para Screening tool

em University of Queensland eSpace - Australia


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study examined the test performance of distortion product otoacoustic emissions (DPOAEs) when used as a screening tool in the school setting. A total of 1003 children (mean age 6.2 years, SD = 0.4) were tested with pure-tone screening, tympanometry, and DPOAE assessment. Optimal DPOAE test performance was determined in comparison with pure-tone screening results using clinical decision analysis. The results showed hit rates of 0.86, 0.89, and 0.90, and false alarm rates of 0.52, 0.19, and 0.22 for criterion signal-to-noise ratio (SNR) values of 4, 5, and 11 dB at 1.1, 1.9, and 3.8 kHz respectively. DPOAE test performance was compromised at 1.1 kHz. In view of the different test performance characteristics across the frequencies, the use of a fixed SNR as a pass criterion for all frequencies in DPOAE assessments is not recommended. When compared to pure tone plus tympanometry results, the DPOAEs showed deterioration in test performance, suggesting that the use of DPOAEs alone might miss children with subtle middle ear dysfunction. However, when the results of a test protocol, which incorporates both DPOAEs and tympanometry, were used in comparison with the gold standard of pure-tone screening plus tympanometry, test performance was enhanced. In view of its high performance, the use of a protocol that includes both DPOAEs and tympanometry holds promise as a useful tool in the hearing screening of schoolchildren, including difficult-to-test children.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The validity of a brief self-report screening measure for elder abuse was examined on a nationally representative sample of more than 12,000 older women it? the baseline survey of the Australian Longitudinal Study on Women's Health. The screening instrument was a modification Of the Hwalek-Sengstock Elder Abuse Screening Test. Construct validity was examined using factor analysis and correlation with a wide range of sociodemographic, psychological. and health-related variables. Four factors, each of three items, were identified representing the following domains: Vulnerability, Dependence, Dejection, and Coercion. The Vulnerability and Coercion factors had the highest face validity for abuse and demonstrated moderate to good construct validity. The six items comprising these factors may provide a simple screening tool for elder abuse The identified correlates of abuse indicators have the potential to enhance policy development, screening, intervention, and carer support programs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background The prevalence of left ventricular hypertrophy (LVH), coronary artery disease, and subclinical cardiomyopathy in diabetic patients without known cardiac disease is unclear. We sought the frequency of these findings to determine whether plasma brain natriuretic peptide (BNP) could be used as an alternative screening tool to identify subclinical LV dysfunction. Methods Asymptomatic patients with diabetes mellitus without known cardiac disease (n = 10 1) underwent clinical evaluation, measurement of BNP, exercise stress testing, and detailed echocardiographic assessment. After exclusion of overt dysfunction or ischemia, subclinical myocardial function was sought on the basis of myocardial systolic (Sm) and diastolic velocity (Em). Association was. sought between subclinical dysfunction and clinical, biochemical, exercise, and echocardiographic variables. Results Of 101 patients, 22 had LVH and 16 had ischemia evidenced by exercise-induced wall motion abnormalities. Only 4 patients had abnormal BNP levels; BNP was significantly increased in patients with LVH. After exclusion of LVH and coronary artery disease, subclinical cardiomyopathy was identified in 24 of 66 patients: Subclinical disease could not be predicted by BNP. Conclusions Even after exclusion of asymptomatic ischemia and hypertrophy, subclinical systolic and diastolic dysfunction occurs in a significant number of patients with type 2 diabetes. However, screening approaches, including BNP, do not appear to be sufficiently sensitive to identify subclinical dysfunction, which requires sophisticated echocardiographic analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: premature infants are at increased risk of developmental disability. Early identification of problems allows intervention to ameliorate or attenuate problems. A reliable screening tool allows triage of children in this high-risk population by identifying those unlikely to need full developmental assessment. To explore the test characteristics of an established parent-completed developmental assessment questionnaire 'Ages and Stages Questionnaire' (ASQ) in follow up of an Australian population of premature infants. Methodology: One hundred and sixty-seven children born prematurely with corrected ages 12- to 48-months attending the Growth and Development Clinic at the Mater Children's Hospital in Brisbane, Queensland, Australia; 136 questionnaires 'ASQ' were returned completed (81%) and were compared to formal psychometric assessment (Griffith Mental Development Scales for 12- and 24-months, Bayley Mental Development Intelligence Scale for 18-months, McCarthy General Cognitive Intelligence Scale for 18-months). Developmental delay was considered to be present if any of the above psychometric assessments fell below 1.0 standard deviations (SD). The ASQ cut-off used was 2.0 SD (US data derived means and SD). Results: Aggregate results for all age groups comparing ASQ to psychometric assessments as 'gold standards' found the ASQ to have the following test characteristics: sensitivity (90%); specificity (77%); positive predictive value (40%); negative predictive value (98%): % over-referred (20%); % under-referred (1%); % agreement (79%). likelihood ratio for children failing the ASQ was 3.8 and for passing the ASQ was 0.13. Twenty-one children with known disabilities were included in the study and in 14 of these, the ASQ overall score agreed with the psychometric assessment (67%). Conclusion: The high negative predictive value of the ASQ supports its use as a screening tool for cognitive and motor delays in the follow up of ex-premature infants. This would need to be combined with other strategies as part of a comprehensive follow up program for ex-premature infants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background The Hospital Anxiety and Depression Scale (HADS) is a widely used screening tool designed as a case detector for clinically relevant anxiety and depression. Recent studies of the HADS in coronary heart disease (CHD) patients in European countries suggest it comprises three, rather than two, underlying sub-scale dimensions. The factor structure of the Chinese version of the HADS was evaluated in patients with CHD in mainland China. Methods Confirmatory factor analysis (CFA) was conducted on self-report HADS forms from 154 Chinese CHD patients. Results Little difference was observed in model fit between best performing three-factor and two-factor models. Conclusion The current observations are inconsistent with recent studies highlighting a dominant underlying tri-dimensional structure to the HADS in CHD patients. The Chinese version of the HADS may perform differently to European language versions of the instrument in patients with CHD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Physical activity (PA) is relevant to the prevention and management of many health conditions in family practice. There is a need for an efficient, reliable, and valid assessment tool to identify patients in need of PA interventions. Methods: Twenty-eight family physicians in three Australian cities assessed the PA of their adult patients during 2004 using either a two- (2Q) or three-question (3Q) assessment. This was administered again approximately 3 days later to evaluate test-retest reliability. Concurrent validity was evaluated by measuring agreement with the Active Australia Questionnaire, and criterion validity by comparison with 7-day Computer Science Applications, Inc. (CSA) accelerometer counts. Results: A total of 509 patients participated, with 428 (84%) completing a repeat assessment, and 415 (82%) accelerometer monitoring. The brief assessments had moderate test-retest reliability (2Q k = 58.0%, 95% confidence interval [CI] = 47.2-68.8%; 3Q k = 55.6%, 95% CI = 43.8-67.4%); fair to moderate concurrent validity (2Q k = 46.7%, 95% CI = 35.657.9%; 3Q k = 38.7%, 95% CI = 26.4-51.1%); and poor to fair criterion validity (2Q k = 18.2%, 95% CI = 3.9-32.6%; 3Q k = 24.3%, 95% CI = 11.6-36.9%) for identifying patients as sufficiently active. A four-level scale of PA derived from the PA assessments was significantly correlated with accelerometer minutes (2Q rho = 0.39, 95% CI = 0.28-0.49; 3Q rho = 0.31, 95% CI = 0.18-0.43). Physicians reported that the assessments took I to 2 minutes to complete. Conclusions: Both PA assessments were feasible to use in family practice, and were suitable for identifying the least active patients. The 2Q assessment was preferred by clinicians and may be most appropriate for dissemination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mounting concerns regarding the environmental impact of herbicides has meant a growing requirement for accurate, timely information regarding herbicide residue contamination of, in particular, aquatic systems. Conventional methods of detection remain limited in terms of practicality due to high costs of operation and the specialised information that analysis provides. A new phytotoxicity bioassay was trialled for the detection of herbicide residues in filter-purified (Milli-Q) as well as natural waters. The performance of the system, which combines solid-phase extraction (SPE) with the ToxY-PAM dual-channel yield analyser (Heinz Walz GmbH), was tested alongside the traditional method of liquid chromatography-mass spectrometry (LC-MS). The assay methodology was found to be highly sensitive (LOD 0.1 ng L-1 diuron) with good reproducibility. The study showed that the assay protocol is time effective and can be employed for the aquatic screening of herbicide residues in purified as well as natural waters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contrast enhanced magnetic resonance imaging (CE MRI) is the most sensitive tool for screening women who are at high familial risk of breast cancer. Our aim in this study was to assess the cost-effectiveness of X-ray mammography (XRM), CE MRI or both strategies combined. In total, 649 women were enrolled in the MARIBS study and screened with both CE MRI and mammography resulting in 1881 screens and 1-7 individual annual screening events. Women aged 35-49 years at high risk of breast cancer, either because they have a strong family history of breast cancer or are tested carriers of a BRCA1, BRCA2 or TP53 mutation or are at a 50% risk of having inherited such a mutation, were recruited from 22 centres and offered annual MRI and XRM for between 2 and 7 years. Information on the number and type of further investigations was collected and specifically calculated unit costs were used to calculate the incremental cost per cancer detected. The numbers of cancer detected was 13 for mammography, 27 for CE MRI and 33 for mammography and CE MRI combined. In the subgroup of BRCA1 (BRCA2) mutation carriers or of women having a first degree relative with a mutation in BRCA1 (BRCA2) corresponding numbers were 3 (6), 12 (7) and 12 (11), respectively. For all women, the incremental cost per cancer detected with CE MRI and mammography combined was 28 pound 284 compared to mammography. When only BRCA1 or the BRCA2 groups were considered, this cost would be reduced to 11 pound 731 (CE MRI vs mammography) and 15 pound 302 (CE MRI and mammography vs mammography). Results were most sensitive to the unit cost estimate for a CE MRI screening test. Contrast-enhanced MRI might be a cost-effective screening modality for women at high risk, particularly for the BRCA1 and BRCA2 subgroups. Further work is needed to assess the impact of screening on mortality and health-related quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of students undertaking fieldwork education placements is a critical process in the health professions. As training programs and practice evolve, systems for assessing students need to be reviewed and updated constantly. In 1995, staff of the occupational therapy training program at the University of Queensland, Australia decided to develop a new tool for assessing student fieldwork performance. Using an action research methodology, a team developed the Student Placement Evaluation Form, a flexible and comprehensive criterion-referenced evaluation tool. The present paper examines action research as an appropriate methodology for considering real-life organisational problems in a systematic and participatory manner. The action research cycles undertaken, including preliminary information gathering, tool development, trial stages and current use of the tool, are detailed in the report. Current and future development of the tool is also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faced with today’s ill-structured business environment of fast-paced change and rising uncertainty, organizations have been searching for management tools that will perform satisfactorily under such ambiguous conditions. In the arena of managerial decision making, one of the approaches being assessed is the use of intuition. Based on our definition of intuition as a non-sequential information-processing mode, which comprises both cognitive and affective elements and results in direct knowing without any use of conscious reasoning, we develop a testable model of integrated analytical and intuitive decision making and propose ways to measure the use of intuition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combination of deductive reasoning, clustering, and inductive learning is given as an example of a hybrid system for exploratory data analysis. Visualization is replaced by a dialogue with the data.