12 resultados para Safety instrumented system

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the implementation of a TMR (Triple Modular Redundant) microprocessor system on a FPGA. The system exhibits true redundancy in that three instances of the same processor system (both software and hardware) are executed in parallel. The described system uses software to control external peripherals and a voter is used to output correct results. An error indication is asserted whenever two of the three outputs match or all three outputs disagree. The software has been implemented to conform to a particular safety critical coding guideline/standard which is popular in industry. The system was verified by injecting various faults into it.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most consumers consider complementary and alternative medicine (CAM) products inherently safe. The growing simultaneous use of CAM products and pharmaceutical drugs by Australian consumers increases the risk of CAM-drug interactions. The Therapeutic Goods Administration (TGA) has a two-tier, risk-based regulatory system for therapeutic goods - CAM products are regulated as low risk products and are assessed for quality and safety; and sponsors of products must hold the evidence for any claim of efficacy made about them. Adverse reactions to CAM products can be classified as intrinsic (innate to the product), or extrinsic (where the risk is not related to the product itself, but results from the failure of good manufacturing practice). Adverse reactions to CAM practices can be classified as risks of commission (which includes removal of medical therapy) and risks of omission (which includes failure to refer when appropriate). While few systematic studies of adverse events with CAM exist, and under-reporting is likely, most CAM products and practices do not appear to present a high risk; their safety needs to be put into the perspective of wider safety issues. A priority for research is to rigorously define the risks associated with both CAM products and practices so that their potential impact on public health can be assessed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microscopic traffic-simulation tools are increasingly being applied to evaluate the impacts of a wide variety of intelligent transport, systems (ITS) applications and other dynamic problems that are difficult to solve using traditional analytical models. The accuracy of a traffic-simulation system depends highly on the quality of the traffic-flow model at its core, with the two main critical components being the car-following and lane-changing models. This paper presents findings from a comparative evaluation of car-following behavior in a number of traffic simulators [advanced interactive microscopic simulator for urban and nonurban networks (AIMSUN), parallel microscopic simulation (PARAMICS), and Verkehr in Statiten-simulation (VISSIM)]. The car-following algorithms used in these simulators have been developed from a variety of theoretical backgrounds and are reported to have been calibrated on a number of different data sets. Very few independent studies have attempted to evaluate the performance of the underlying algorithms based on the same data set. The results reported in this study are based on a car-following experiment that used instrumented vehicles to record the speed and relative distance between follower and leader vehicles on a one-lane road. The experiment was replicated in each tool and the simulated car-following behavior was compared to the field data using a number of error tests. The results showed lower error values for the Gipps-based models implemented in AIMSUN and similar error values for the psychophysical spacing models used in VISSIM and PARAMICS. A qualitative drift and goal-seeking behavior test, which essentially shows how the distance headway between leader and follower vehicles should oscillate around a stable distance, also confirmed the findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Chaperonin 10 (heat shock protein 10, XToll(TM)) has anti-inflammatory properties related to the inhibition of Toll-like receptor signalling pathways. Our aim was to establish whether chaperonin 10 is safe and effective in the treatment of rheumatoid arthritis. Methods in this randomised, double-blind, multicentre study, 23 patients with moderate to severe active rheumatoid arthritis receiving disease-modifying antirheumatic drugs were randomly allocated to three treatment groups receiving intravenous chaperonin 10 twice weekly for 12 weeks at doses of 5 mg (n=8), 7.5 mg (8), or 10 mg (7). The primary outcomes were change in disease activity score (DAS28) and improvement of core disease measures (American College of Rheumatology response score) from baseline to week 12. All analyses were done by intention to treat. This study is registered with the Australian Clinical Trials Registry, number ACTRNO12606000041550. Findings Primary endpoint measures improved from day 14 in all groups and continued to improve to day 84. By end of study, a 20% improvement of core disease measures was seen in six (86%, 95% Cl 43-100), a 50% improvement in four (57%, 14-86), and a 70% improvement in two (29%, 0-57) patients given the highest dose of chaperonin 10. Clinical remission (as defined by a DAS28

Relevância:

30.00% 30.00%

Publicador: