7 resultados para SCINTILLATION COUNTING
em University of Queensland eSpace - Australia
Resumo:
The effects of three vehicles, phosphate-buffered saline (PBS), ethanol (50% in PBS w/w) and propylene glycol (50% in PBS w/w) on in vitro transdermal penetration of testosterone was investigated in the horse. Skin was harvested from the thorax of five Thoroughbred horses after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into Franz-type diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled [C-14]testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when testosterone was dissolved in a vehicle containing 50% ethanol or 50% propylene glycol, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in clinical response to testosterone could be expected with formulation design.
Resumo:
The effects of the vehicles phosphate-buffered saline (PBS), ethanol (EtOH; 50% in PBS w/w) and propylene glycol (PG; 50% in PBS w/w) and the region of administration on in vitro transdermal penetration of testosterone was investigated in the dog. Skin was harvested from the thorax, neck (dorsal part) and groin regions of greyhounds after euthanasia and stored at -20 degrees C until required. The skin was then de-frosted and placed into Franz-type diffusion cells which were maintained at approximately 32 degrees C by a water-bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled (C-14) testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH or 50% PG, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in percutaneous penetration of testosterone could be expected with formulation design and site of application. (C) 2004 Elsevier Ltd. All rights reserved.
Counting the dead and what they died from: An assessment of the global status of cause of death data
Resumo:
We analyze photoionization and ion detection as a means of accurately counting ultracold atoms. We show that it is possible to count clouds containing many thousands of atoms with accuracies better than N-1/2 with current technology. This allows the direct probing of sub-Poissonian number statistics of atomic samples. The scheme can also be used for efficient single-atom detection with high spatiotemporal resolution. All aspects of a realistic detection scheme are considered, and we discuss experimental situations in which such a scheme could be implemented.
Resumo:
We study Greenberger-Horne-Zeilinger-type (GHZ-type) and W-type three-mode entangled coherent states. Both types of entangled coherent states violate Mermin's version of the Bell inequality with threshold photon detection (i.e., without photon counting). Such an experiment can be performed using linear optics elements and threshold detectors with significant Bell violations for GHZ-type entangled coherent states. However, to demonstrate Bell-type inequality violations for W-type entangled coherent states, additional nonlinear interactions are needed. We also propose an optical scheme to generate W-type entangled coherent states in free-traveling optical fields. The required resources for the generation are a single-photon source, a coherent state source, beam splitters, phase shifters, photodetectors, and Kerr nonlinearities. Our scheme does not necessarily require strong Kerr nonlinear interactions; i.e., weak nonlinearities can be used for the generation of the W-type entangled coherent states. Furthermore, it is also robust against inefficiencies of the single-photon source and the photon detectors.
Resumo:
Proceedings of the 11th Australasian Remote Sensing and Photogrammetry Conference