5 resultados para Resistance parameters

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An important functional and evolutionary constraint on the physical performance of vertebrates is believed to be the trade-off between speed and endurance capacity. However, despite the pervasiveness of physiological arguments, most studies have found no evidence of the trade-off when tested at the whole-animal level. We investigated the existence of this trade-off at the whole-muscle level, the presumed site of this physiological conflict, by examining inter-individual variation in both maximum power output and fatigue resistance for mouse extensor digitorum longus (EDL) muscle using the work-loop technique. We found negative correlations between several measures of in vitro maximum power output and force production with fatigue resistance for individual mouse EDL muscles, indicating functional trade-offs between these performance parameters. We suggest that this trade-off detected at the whole-muscle level has imposed an important constraint on the evolution of vertebrate physical performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. Design Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. Procedure All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. Results These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the maximising method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific normal left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. Conclusion These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thickness, chemical composition and microstructure of anodised coatings formed on magnesium alloy AZ91D at various anodising current densities were measured. It was found that all these parameters could be affected by anodising current density, and hence the coatings formed at different anodising current densities had different corrosion resistances. This suggests that the corrosion performance of an anodised coating could be improved if a properly designed current waveform is used for anodising. In addition, based on the experimental results, some physical, chemical and electrochemical reactions involved in the anodising process were proposed to explain the anodising behaviour in this paper. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, nonlinear curve fitting. An alternative fitting method is described that uses only the magnitude of the measured impedances at four selected frequencies. The two methods showed excellent agreement when compared using data obtained both from measurements of equivalent circuits and of humans. These results suggest that operational equivalence to a technically complex, frequency-scanning, phase-sensitive BIS analyser could be achieved from a simple four-frequency, impedance-only analyser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim was to investigate whether the addition of supervised high intensity progressive resistance training to a moderate weight loss program (RT+WLoss) could maintain bone mineral density (BMD) and lean mass compared to moderate weight loss (WLoss) alone in older overweight adults with type 2 diabetes. We also investigated whether any benefits derived from a supervised RT program could be sustained through an additional home-based program. This was a 12-month trial in which 36 sedentary, overweight adults aged 60 to 80 years with type 2 diabetes were randomized to either a supervised gymnasium-based RT+WLoss or WLoss program for 6 months (phase 1). Thereafter, all participants completed an additional 6-month home-based training without further dietary modification (phase 2). Total body and regional BMD and bone mineral content (BMC), fat mass (FM) and lean mass (LM) were assessed by DXA every 6 months. Diet, muscle strength (1-RM) and serum total testosterone, estradiol, SHBG, insulin and IGF-1 were measured every 3 months. No between group differences were detected for changes in any of the hormonal parameters at any measurement point. In phase 1, after 6 months of gymnasium-based training, weight and FM decreased similarly in both groups (P < 0.01), but LM tended to increase in the RT+WLoss (n=16) relative to the WLoss (n = 13) group [net difference (95% CI), 1.8% (0.2, 3.5), P < 0.05]. Total body BMD and BMC remained unchanged in the RT+WLoss group, but decreased by 0.9 and 1.5%, respectively, in the WLoss group (interaction, P < 0.05). Similar, though non-significant, changes were detected at the femoral neck and lumbar spine (L2-L4). In phase 2, after a further 6 months of home-based training, weight and FM increased significantly in both the RT+WLoss (n = 14) and WLoss (n = 12) group, but there were no significant changes in LM or total body or regional BMD or BMC in either group from 6 to 12 months. These results indicate that in older, overweight adults with type 2 diabetes, dietary modification should be combined with progressive resistance training to optimize the effects on body composition without having a negative effect on bone health.