102 resultados para RTÉ

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The plasmalemmal Ca2+ adenosine triphosphatase (PMCA) is a key regulator of Ca2+ efflux in vascular smooth muscle. In these studies are developed a realtime reverse transcriptase-polymerase chain reaction (real-time RT-PCR) assay for assessing PMCA1 mRNA levels in rat primary cultured aortic myocytes. This assay detected fetal bovine serum-induced increases in PMCA1 mRNA (relative to 18S rRNA) 4, 8, and 24 h after stimulation. Early fetal bovine serum-induced increases in PMCA1 mRNA were insensitive to the Ca2+ channel blockers nifedipine, flunarizine, and SKF-96365. These studies demonstrate the feasibility of real-time RT-PCR to assess mRNA levels of PMCA1 and illustrate dynamic regulation of this Ca2+ pump isoform in rat primary cultured aortic myocytes, (C) 2000 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The plasma membrane Ca2+ pump is a key regulator of cytosolic free Ca2+. Recent studies have demonstrated the dynamic expression of the plasma membrane Ca2+ pump in a variety of cell types. Furthermore, alterations in plasma membrane calcium pump activity have now been implicated in human disease. In this study, the development of a technique to quantitatively assess mRNA expression of the human plasma membrane Ca2+ ATPase (PMCA1) isoform of the plasma membrane Ca2+ pump, using a real-time reverse transcriptase-polymerase chain reaction (real-time RT-PCR) assay in a human breast epithelial cell line (MCF-7) is described. The sequences of the PMCA1 primers and probe for real-time RT-PCR are presented. The results also indicate that PMCA1 mRNA can be normalized to both 18S ribosomal RNA (18S rRNA) and human glyceraldehyde-3-phosphate dehydrogenase (hGAPDH) in MCF-7 cells. Real-time RT-PCR will be most useful in assessing PMCA1 mRNA expression in cases where only low amounts of RNA are available and/or when numerous samples must be assessed simultaneously. (C) 2001 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seedborne peanut viruses pose important constraints to peanut production and safe movement of germ plasm. They also pose a risk of accidental introduction into previously disease-free regions. We have developed reverse transcription-polymerase chain reaction (RT-PCR) assays based on identical cycling parameters which identified peanut stripe, Peanut mottle, Peanut stunt, and Cucumber mosaic viruses through production of specific DNA fragments of 234 bp, 327 bp, 390 bp, and 133 bp, respectively. Assay sensitivity in the picogram range was achieved. The two potyviruses and two cucumoviruses could be differentiated using duplex RT-PCR assays. These assays should be useful for testing peanut leaves or seeds for virus identification in epidemiological studies, seed testing or in post-entry quarantine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Roche LightCycler we developed a real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay using the Influenza A LightCycler RT-PCR (FA-LC-RTPCR) for the rapid detection of Influenza A. The assay was used to examine 178 nasopharyngeal aspirate (NPA) samples, from patients with clinically recognised respiratory tract infection, for the presence of Influenza A RNA. The results were then compared to a testing algorithm combining direct immunofluorescent assy (DFA) and a culture augmented DFA (CA-DFA) assay. In total, 76 (43%) specimens were positive and 98 (55%) specimens were negative by both the FA-LC-RTPCR and the DFA and CA-DFA algorithm. In addition, the FA-LC-RTPCR detected a further 4 (2%) positive specimens, which were confirmed by a conventional RT-PCR method. The high level of sensitivity and specificity, combined with the rapid turnaround time for results, makes the LC-RT-PCR assay suitable for the detection of Influenza A in clinical specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The N-methyl-D-aspartate (NMDA)-selective subtype of ionotropic glutamate receptor is of importance in neuronal differentiation and synapse consolidation, activity-dependent forms of synaptic plasticity, and excitatory amino acid-mediated neuronal toxicity [Neurosci. Res. Program, Bull. 19 (1981) 1; Lab. Invest. 68 (1993) 372]. NMDA receptors exist in vivo as tetrameric or pentameric complexes comprising proteins from two families of homologous subunits, designated NR1 and NR2(A-D) [Biochem. Biophys. Res. Commun. 185 (1992) 826]. The gene coding for the human NR1 subunit (hNR1) is composed of 21 exons, three of which (4, 20 and 21) can be differentially spliced to generate a total of eight distinct subunit variants. We detail here a competitive RT-PCR (cRT-PCR) protocol to quantify endogenous levels of hNR1 splice variants in autopsied human brain. Quantitation of each hNR1 splice variant is performed using standard curve methodology in which a known amount of synthetic ribonucleic acid competitor (internal standard) is co-amplified against total RNA. This method can be used for the quantitation of hNR1 mRNA levels in response to acute or chronic disease states, in particular in the glutamatergic-associated neuronal loss observed in Alzheimer's disease [J. Neurochem. 78 (2001) 175]. Furthermore, alterations in hNR1 mRNA expression may be reflected at the translational level, resulting in functional changes in the NMDA receptor. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a competitive RT-PCR assay, adapted from Lewohl et al. [Brain Res. Brain Res. Protoc. 1 (1997) 347]. for the quantitation of GABA, receptor beta isoforms in human brain using an internal standard that shares high sequence homology to the targets. The internal standard is identical to the beta(1) sequence except for a 61 bp deletion and the incorporation of a Hind III restriction enzyme site. Unlike traditional competitive RT-PCR, which requires a range of internal standard concentrations to be titrated against a constant amount of unknown, this method relies on a standard curve for quantitation of each sample and thus permits increased sample throughput. This method is suitable for the quantitation of beta(1), beta(2) and beta(3) isoforms of the GABA(A) receptor in human alcoholic and control brain. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for large-scale use of a sensitive real time reverse transcription polymerase chain reaction (RT-PCR) assay was evaluated for the detection of Tomato spotted wilt virus (TSWV) in single and bulked leaf samples by comparing its sensitivity with that of DAS-ELISA. Using total RNA extracted with RNeasy (R) or leaf soak methods, real time RT-PCR detected TSWV in all infected samples collected from 16 horticultural crop species (including flowers, herbs and vegetables), two arable crop species, and four weed species by both assays. In samples in which DAS-ELISA had previously detected TSWV, real time RT-PCR was effective at detecting it in leaf tissues of all 22 plant species tested at a wide range of concentrations. Bulk samples required more robust and extensive extraction methods with real time RT-PCR, but it generally detected one infected sample in 1000 uninfected ones. By contrast, ELISA was less sensitive when used to test bulked samples, once detecting up to I infected in 800 samples with pepper but never detecting more than I infected in 200 samples in tomato and lettuce. It was also less reliable than real time RT-PCR when used to test samples from parts of the leaf where the virus concentration was low. The genetic variability among Australian isolates of TSWV was small. Direct sequencing of a 587 bp region of the nucleoprotein gene (S RNA) of 29 isolates from diverse crops and geographical locations yielded a maximum of only 4.3% nucleotide sequence difference. Phylogenetic analysis revealed no obvious groupings of isolates according to geographic origin or host species. TSWV isolates, that break TSWV resistance genes in tomato or pepper did not differ significantly in the N gene region studied, indicating that a different region of the virus genome is responsible for this trait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antigenic variation in Plasmodium falciparum erythrocyte membrane protein 1, caused by a switch in transcription of the encoding var gene, is an important feature of malaria. In this study, we quantified the relative abundance of var gene transcripts present in P. falciparum parasite clones using real-time reverse transcription-polymerase chain reaction (RT-PCR) and conventional RT-PCR combined with cloning and sequencing, with the aim of directly comparing the results obtained. When there was sufficient abundance of RNA for the real-time RT-PCR assay to be operating within the region of good reproducibility, RT-PCR and real-time RT-PCR tended to identify the same dominant transcript, although some transcript-specific issues were identified. When there were differences in the estimated relative amounts of minor transcripts, the RT-PCR assay tended to produce higher estimates than real-time RT-PCR. These results provide valuable information comparing RT-PCR and real-time RT-PCR analysis of samples with small quantities of RNA as might be expected in the analysis of field or clinical samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterovirus 71 (EV71) is one of the main causative agents of hand, foot and mouth disease (HFMD) in young children. Infections caused by EV71 could lead to many complications, ranging from brainstem encephalitis to pulmonary oedema, resulting in high mortality. Thus, rapid detection of the virus is required to enable measures to be implemented in preventing widespread transmission. Based on primers and probes targeting at the VP1 region, a real-time reverse-transcriptase polymerase chain reaction (RT-PCR) hybridization probe assay was developed for specific detection of EV71 from clinical specimens. Quantitative analysis showed that the assay was able to detect as low as 5 EV71 viral copies and EV71 was detected from 46 of the 55 clinical specimens obtained from pediatric patients suffering from HFMD during the period from 2000 to 2003 in Singapore. This study showed that the single tube real-time RT-PCR assay developed in this study can be applied as a rapid and sensitive method for specific detection of EV71 directly from clinical specimens. (c) 2005 Elsevier Ltd. All rights reserved.