16 resultados para RAPID METHODS

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed to determine whether including a sensitive test of immediate and delayed recall would improve the diagnostic validity of the Rapid Screen of Concussion (RSC) in mild Traumatic Brain Injury (mTBI) versus orthopaedic clinical samples. Two studies were undertaken. In Study 1, the performance of 156 mTBI and 145 orthopaedic participants was analysed to identify the number of individuals who performed at ceiling on the verbal memory subtest of the RSC, as this test required immediate and delayed recall of only five words. A second aim was to determine the sensitivity and specificity levels of the RSC. Study 2 aimed to examine whether replacement of the verbal memory subtest with the 12-word Hopkins Verbal Learning Test (HVLT) could improve the sensitivity of the RSC in a new sample of 26 mTBI and 30 orthopaedic participants. Both studies showed that orthopaedic participants outperformed mTBI participants on each of the selected measures. Study 1 showed that 14% of mTBI participants performed at ceiling on the immediate and 21.2% on delayed recall test. Performance on the original battery yielded a sensitivity of 82%, specificity of 80% and overall correct classification of 81.5% participants. In Study 2, inclusion of the HVLT improved sensitivity to a level of 88.5%, decreased specificity to a level of 70% and resulted in an overall classification rate of 80%. It was concluded that although inclusion of the five-word subtest in the RSC can successfully distinguish concussed from non-concussed individuals, use of the HVLT in this protocol yields a more sensitive measure of subtle cognitive deficits following mTBI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The precise evaluation of electromagnetic field (EMF) distributions inside biological samples is becoming an increasingly important design requirement for high field MRI systems. In evaluating the induced fields caused by magnetic field gradients and RF transmitter coils, a multilayered dielectric spherical head model is proposed to provide a better understanding of electromagnetic interactions when compared to a traditional homogeneous head phantom. This paper presents Debye potential (DP) and Dyadic Green's function (DGF)-based solutions of the EMFs inside a head-sized, stratified sphere with similar radial conductivity and permittivity profiles as a human head. The DP approach is formulated for the symmetric case in which the source is a circular loop carrying a harmonic-formed current over a wide frequency range. The DGF method is developed for generic cases in which the source may be any kind of RF coil whose current distribution can be evaluated using the method of moments. The calculated EMFs can then be used to deduce MRI imaging parameters. The proposed methods, while not representing the full complexity of a head model, offer advantages in rapid prototyping as the computation times are much lower than a full finite difference time domain calculation using a complex head model. Test examples demonstrate the capability of the proposed models/methods. It is anticipated that this model will be of particular value for high field MRI applications, especially the rapid evaluation of RF resonator (surface and volume coils) and high performance gradient set designs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C-18 column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r(2)) > 0.997 over the concentration range 0.5-60.0 mug/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This paper describes SeqDoC, a simple, web-based tool to carry out direct comparison of ABI sequence chromatograms. This allows the rapid identification of single nucleotide polymorphisms (SNPs) and point mutations without the need to install or learn more complicated analysis software. Results: SeqDoC produces a subtracted trace showing differences between a reference and test chromatogram, and is optimised to emphasise those characteristic of single base changes. It automatically aligns sequences, and produces straightforward graphical output. The use of direct comparison of the sequence chromatograms means that artefacts introduced by automatic base-calling software are avoided. Homozygous and heterozygous substitutions and insertion/deletion events are all readily identified. SeqDoC successfully highlights nucleotide changes missed by the Staden package 'tracediff' program. Conclusion: SeqDoC is ideal for small-scale SNP identification, for identification of changes in random mutagenesis screens, and for verification of PCR amplification fidelity. Differences are highlighted, not interpreted, allowing the investigator to make the ultimate decision on the nature of the change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Older adults typically exhibit dramatic reductions in the rate of force development and deficits in the execution of rapid coordinated movements. The purpose of the current study was to investigate the association between the reduced rate of force development exhibited by older adults and the ability to coordinate groups of muscles. Methods. The performance of a visually guided aiming task that required the generation of isometric torque about the elbow joint was compared in 10 young adults (age range, 19 to 29 years) and 10 older adults (age range, 65 to 80 years). Participants were required to exert isometric torque in flexion, extension, pronation, or supination, or in combinations of these directions, to reach a target in minimum time. Surface electromyograms were obtained from the biceps brachii, triceps brachii, brachioradialis, and flexor carpi radialis. Results. Older participants exhibited slower target acquisition times compared with young participants (p < .05), with the extent of the differences between the groups varying markedly between target locations. Conclusions. The impairment in performance, although partially attributable to a general decline in the ability to produce force rapidly, was also affected by the requirements for muscular coordination. At the neuromuscular level, differences between the young and the elderly were expressed most prominently in the bifunctional muscle biceps brachii and in certain temporal aspects of muscular coordination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indomethacin (IND) is the drug of choice for the closure of a patent ductus arteriosus (PDA) in neonates. This paper describes a simple, sensitive, accurate and precise microscale HPLC method suitable for the analysis of IND in plasma of premature neonates. Samples were prepared by plasma protein precipitation with acetonitrile containing the methyl ester of IND as the internal standard (IS). Chromatography was performed on a Hypersil C-18 column. The mobile phase of methanol, water and orthophosphoric acid (70:29.5:0.5, v/v, respectively), was delivered at 1.5 mL/min and monitored at 270 nm. IND and the IS were eluted at 2.9 and 4.3 min, respectively. Calibrations were linear (r > 0.999) from 25 to 2500 mu g/L. The inter- and intra-day assay imprecision was less than 4.3% at 400-2000 mu g/L, and less than 22.1% at 35 mu g/L. Inaccuracy ranged from -6.0% to +1.0% from 35 to 2000 mu g/L. The absolute recovery of IND over this range was 93.0-113.3%. The IS was stable for at least 36 h when added to plasma at ambient temperature. This method is suitable for pharmacokinetic studies of IND and has potential for monitoring therapy in infants with PDA when a target therapeutic range for IND has been validated. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Insoluble expression of heterologous proteins in Escherichia coli is a major bottleneck of many structural genomics and high-throughput protein biochemistry projects. Many of these proteins may be amenable to refolding, but their identification is hampered by a lack of high-throughput methods. We have developed a matrix-assisted refolding approach in which correctly folded proteins are distinguished from misfolded proteins by their elution from affinity resin under nondenaturing conditions. Misfolded proteins remain adhered to the resin, presumably via hydrophobic interactions. The assay can be applied to insoluble proteins on an individual basis but is particularly well suited for high-throughput applications because it is rapid, automatable and has no rigorous sample preparation requirements. The efficacy of the screen is demonstrated on small-scale expression samples for 15 proteins. Refolding is then validated by large-scale expressions using SEC and circular dichroism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forty-four soils from under native vegetation and a range of management practices following clearing were analysed for ‘labile’ organic carbon (OC) using both the particulate organic carbon (POC) and the 333 mm KmnO4 (MnoxC) methods. Although there was some correlation between the 2 methods, the POC method was more sensitive by about a factor of 2 to rapid loss in OC as a result of management or land-use change. Unlike the POC method, the MnoxC method was insensitive to rapid gains in TOC following establishment of pasture on degraded soil. The MnoxC method was shown to be particularly sensitive to the presence of lignin or lignin-like compounds and therefore is likely to be very sensitive to the nature of the vegetation present at or near the time of sampling and explains the insensitivity of this method to OC gain under pasture. The presence of charcoal is an issue with both techniques, but whereas the charcoal contribution to the POC fraction can be assessed, the MnoxC method cannot distinguish between charcoal and most biomolecules found in soil. Because of these limitations, the MnoxC method should not be applied indiscriminately across different soil types and management practices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This economic evaluation was part of the Australian National Evaluation of Pharmacotherapies for Opioid Dependence (NEPOD) project. Data from four trials of heroin detoxification methods, involving 365 participants, were pooled to enable a comprehensive comparison of the cost-effectiveness of five inpatient and outpatient detoxification methods. This study took the perspective of the treatment provider in assessing resource use and costs. Two short-term outcome measures were used-achievement of an initial 7-day period of abstinence, and entry into ongoing post-detoxification treatment. The mean costs of the various detoxification methods ranged widely, from AUD $491 (buprenorphine-based outpatient); to AUD $605 for conventional outpatient; AUD $1404 for conventional inpatient; AUD $1990 for rapid detoxification under sedation; and to AUD $2689 for anaesthesia per episode. An incremental cost-effectiveness analysis was carried out using conventional outpatient detoxification as the base comparator. The buprenorphine-based outpatient detoxification method was found to be the most cost-effective method overall, and rapid opioid detoxification under sedation was the most costeffective inpatient method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Experimental study of muscle changes after lumbar spinal injury. Objectives. To investigate effects of intervertebral disc and nerve root lesions on cross-sectional area, histology and chemistry of porcine lumbar multifidus. Summary of Background Data. The multifidus cross-sectional area is reduced in acute and chronic low back pain. Although chronic changes are widespread, acute changes at 1 segment are identified within days of injury. It is uncertain whether changes precede or follow injury, or what is the mechanism. Methods. The multifidus cross-sectional area was measured in 21 pigs from L1 to S1 with ultrasound before and 3 or 6 days after lesions: incision into L3 - L4 disc, medial branch transection of the L3 dorsal ramus, and a sham procedure. Samples from L3 to L5 were studied histologically and chemically. Results. The multifidus cross-sectional area was reduced at L4 ipsilateral to disc lesion but at L4 - L6 after nerve lesion. There was no change after sham or on the opposite side. Water and lactate were reduced bilaterally after disc lesion and ipsilateral to nerve lesion. Histology revealed enlargement of adipocytes and clustering of myofibers at multiple levels after disc and nerve lesions. Conclusions. These data resolve the controversy that the multifidus cross-sectional area reduces rapidly after lumbar injury. Changes after disc lesion affect 1 level with a different distribution to denervation. Such changes may be due to disuse following reflex inhibitory mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary objectives: (1) To investigate the Nonword Repetition test (NWR) as an index of sub-vocal rehearsal deficits after mild traumatic brain injury (mTBI); (2) to assess the reliability, validity and sensitivity of the NWR; and (3) to compare the NWR to more sensitive tests of verbal memory. Research design: An independent groups design. Methods and procedures: Study 1 administered the NWR to 46 mTBI and 61 uninjured controls with the Rapid Screen of Concussion (RSC). Study 2 compared mTBI, orthopaedic and uninjured participants on the NWR and the Hopkins Verbal Learning Test (HVLT-R). Main outcomes and results: The NWR did not improve the diagnostic accuracy of the RSC. However, it is reliable and indexes sub-vocal rehearsal speed. These findings provide evidence that although the current form of the NWR lacks sensitivity to the impact of mTBI, the development of a more sensitive test of sub-vocal rehearsal deficits following mTBI is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The BRAF gene is frequently somatically altered in malignant melanoma. A majority of variations are at the valine 600 residue leading to a V600E substitution that constitutively activates the kinase. We screened 4000 patient and control DNAs for germ-line variations at the valine 600 residue. Methods: We developed a novel assay by adapting single-base variation assays and software for MALDI-TOF (matrix-assisted laser desorption/ionization time-of-flight) mass spectrometry to screen for all 5 reported variants at codon 600 of the BRAF gene. We screened a case-control collection comprising samples from 1082 melanoma patients and 154 of their unaffected relatives from 1278 families and from 2744 individuals from 659 unselected twin families with no history of melanoma. A panel of 66 melanoma cell lines was used for variation-positive controls. Results: All melanoma cell lines that we had found previously to carry a codon 600 variation were verified in this study. Three of the 4 possible variants (V600E n = 47, V600K n = 2, V600R n = 1) were detected, but no case of V600D was available. No germ-line variants were found in the samples from the 3980 melanoma patients or from the control individuals. Conclusions: This new assay is a high-throughput, automated alternative to standard sequencing and can be used as a rapid initial screen for somatic variants associated with melanoma. Germ-line variants at valine 600 are unlikely to exist and do not contribute to the reported role of the BRAF gene in melanoma predisposition. (c) 2006 American Association for Clinical Chemistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.