26 resultados para Precision nutrition

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of temporal precision constraints and movement amplitude on performance of an interceptive aiming task were examined. Participants were required to strike a moving target object with a 'bat' by moving the bat along a straight path (constrained by a linear slide) perpendicular to the path of the target. Temporal precision constraints were defined in terms of the time period (or window) within which contact with the target was possible. Three time windows were used (approx. 35, 50 and 65 ms) and these were achieved either by manipulating the size of the bat (experiment 1a), the size of the target (experiment 1b) or the speed of the target (experiment 2). In all experiments, movement time (MT) increased in proportion to movement amplitude but was only affected by differences in the temporal precision constraint if this was achieved by variation in the target's speed. In this case the MT was approximately inversely proportional to target speed. Peak movement speed was affected by temporal accuracy constraints in all three experiments: participants reached higher speeds when the temporal precision required was greater. These results are discussed with reference to the speed-accuracy trade-off observed for temporally constrained aiming movements. It is suggested that the MT and speed of interceptive aiming movements may be understood as responses to the spatiotemporal constraints of the task.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New techniques in air-displacement plethysmography seem to have overcome many of the previous problems of poor reproducibility and validity. These have made body-density measurements available to a larger range of individuals, including children, elderly and sick patients who often have difficulties in being submerged underwater in hydrodensitometry systems. The BOD POD air-displacement system (BOD POD body composition system; Life Measurement Instruments, Concord, CA, USA) is more precise than hydrodensitometry, is simple and rapid to operate (approximately 1 min measurements) and the results agree closely with those of hydrodensitometry (e.g. +/-3.4% for estimation of body fat). Body line scanners employing the principles of three-dimensional photography are potentially able to measure the surface area and volume of the body and its segments even more rapidly (approximately 10 s), but the validity of the measurements needs to be established. Advances in i.r. spectroscopy and mathematical modelling for calculating the area under the curve have improved precision for measuring enrichment of (H2O)-H-2 in studies of water dilution (CV 0.1-0.9% within the range of 400-1000 mu l/l) in saliva, plasma and urine. The technique is rapid and compares closely with mass spectrometry (bias 1 (SD 2) %). Advances in bedside bioelectrical-impedance techniques are making possible potential measurements of skinfold thicknesses and limb muscle mass electronically. Preliminary results suggest that the electronic method is more reproducible (intra-and inter-individual reproducibility for measuring skinfold thicknesses) and associated with less bias (+ 12%), than anthropometry (+ 40%). In addition to these selected examples, the 'mobility' or transfer of reference methods between centres has made the distinction between reference and bedside or field techniques less distinct than in the past.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in the application of bioelectrical impedance analysis (BIA) have indicated that a more accurate approach to the estimation of total body water is to consider the impedance of the various body segments rather than simply that of the whole body. The segmental approach necessitates defining and locating the physical demarcation between both the trunk and leg and the trunk and arm. Despite the use of anatomical markers, these points of demarcation are difficult to locate with precision between subjects. There are also technical problems associated with the regional dispersion of the current distribution from one segment (cylinder) to another of different cross-sectional area. The concept of equipotentials in line with the proximal aspects of the upper land lower) limbs along the contralateral limbs was investigated and, in particular, the utility of this concept in the measurement of segmental bioimpedance. The variation of measured segmental impedance using electrode sites along these equipotentials was less than 2.0% for all of the commonly used impedance parameters. This variation is approximately equal to that expected from biological variation over the measurement time. It is recommended that the electrode sites, for the measurement of segmental bioelectrical impedance in humans, described herein are adopted in accordance with the proposals of the NM Technology Assessment Conference Statement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

.:Abstract-Objective: Bioelectrical impedance analysis (BIA) is widely used as bedside assessment of body composition. Body cell mass (BCM) and intracellular water (ICW) are clinically important body compartments. Estimates of ICW obtained from BIA by different calculation approaches were compared to a reference method in male HIV-infected patients. Patients: Representative subsample of clinically stable HIV-infected outpatients, consisting of 42 men with a body mass index of 22.4 +/- 3.8 kg/m(2) (range, 13-31 kg/m(2)). Methods: Total body potassium was assessed in a whole body counter, and compared to 50 kHz mono-frequency BIA and multifrequency bioelectrical impedance spectroscopy. Six different prediction equations for ICW from BIA data were applied. Methods were compared by the Bland-Altman method. Results: BIA-derived ICW estimates explained 58% to 73% of the observed variance in ICW (TBK), but limits of confidence were wide (-16.6 to +18.2% for the best method). BIA overestimated low ICW (TBK) and underestimated high ICW (TBK) when normalized for weight or height. Mono- and multifrequency BIA were not different in precision but population-specific equations tended to narrower confidence limits. Conclusion: BIA is an unreliable method to estimate ICW in this population, in contrast to the better established estimation of total body water and extracellular water. Potassium depletion in severe malnutrition may contribute to this finding but a major part of the residual between methods remains unexplained. (C) 2000 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Las Campanas Observatory and Anglo-Australian Telescope Rich Cluster Survey (LARCS) is a panoramic imaging and spectroscopic survey of an X-ray luminosity-selected sample of 21 clusters of galaxies at 0.07 < z < 0.16. Charge-coupled device (CCD) imaging was obtained in B and R of typically 2 degrees wide regions centred on the 21 clusters, and the galaxy sample selected from the imaging is being used for an on-going spectroscopic survey of the clusters with the 2dF spectrograph on the Anglo-Australian Telescope. This paper presents the reduction of the imaging data and the photometric analysis used in the survey. Based on an overlapping area of 12.3 deg(2) we compare the CCD-based LARCS catalogue with the photographic-based galaxy catalogue used for the input to the 2dF Galaxy Redshift Survey (2dFGRS) from the APM, to the completeness of the GRS/APM catalogue, b(J) = 19.45. This comparison confirms the reliability of the photometry across our mosaics and between the clusters in our survey. This comparison also provides useful information concerning the properties of the GRS/APM. The stellar contamination in the GRS/APM galaxy catalogue is confirmed as around 5-10 per cent, as originally estimated. However, using the superior sensitivity and spatial resolution in the LARCS survey evidence is found for four distinct populations of galaxies that are systematically omitted from the GRS/APM catalogue. The characteristics of the 'missing' galaxy populations are described, reasons for their absence examined and the impact they will have on the conclusions drawn from the 2dF Galaxy Redshift Survey are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six of the short dietary questions used in the 1995 National Nutrition Survey (see box below) were evaluated for relative validity both directly and indirectly and for consistency, by documenting the differences in mean intakes of foods and nutrients as measured on the 24-hour recall, between groups with different responses to the short questions. 1. Including snacks, how many times do you usually have something to eat in a day including evenings? 2. How many days per week do you usually have something to eat for breakfast? 3. In the last 12 months, were there any times that you ran out of food and couldn’t afford to buy more? 4. What type of milk do you usually consume? 5. How many serves of vegetables do you usually eat each day? (a serve = 1/2 cup cooked vegetables or 1 cup of salad vegetables) 6. How many serves of fruit do you usually eat each day? (a serve = 1 medium piece or 2 small pieces of fruit or 1 cup of diced pieces) These comparisons were made for males and females overall and for population sub-groups of interest including: age, socio-economic disadvantage, region of residence, country of birth, and BMI category. Several limitations to this evaluation of the short questions, as discussed in the report, need to be kept in mind including: · The method for comparison available (24-hour recall) was not ideal (gold standard); as it measures yesterday’s intake. This limitation was overcome by examining only mean differences between groups of respondents, since mean intake for a group can provide a reasonable approximation for ‘usual’ intake. · The need to define and identify, post-hoc, from the 24-hour recall the number of eating occasions, and occasions identified by the respondents as breakfast. · Predetermined response categories for some of the questions effectively limited the number of categories available for evaluation. · Other foods and nutrients, not selected for this evaluation, may have an indirect relationship with the question, and might have shown stronger and more consistent responses. · The number of responses in some categories of the short questions eg for food security may have been too small to detect significant differences between population sub-groups. · No information was available to examine the validity of these questions for detecting differences over time (establishing trends) in food habits and indicators of selected nutrient intakes. By contrast, the strength of this evaluation was its very large sample size, (atypical of most validation studies of dietary assessment) and thus, the opportunity to investigate question performance in a range of broad population sub-groups compared with a well-conducted, quantified survey of intakes. The results of the evaluation are summarised below for each of the questions and specific recommendations for future testing, modifications and use provided for each question. The report concludes with some general recommendations for the further development and evaluation of short dietary questions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: For ultra-endurance athletes, whose energy expenditure is likely to be at the extremes of human tolerance for sustained periods of time, there is increased concern regarding meeting energy needs. Due to the lack of data outlining the energy requirements of such athletes, it is possible that those participating in ultra-endurance exercise are compromising performance, as well as health, as a result of inadequate nutrition and energy intake. To provide insight into this dilemma, we have presented a case study of a 37-yr-old ultra-marathon runner as he runs around the coast of Australia. Methods: Total energy expenditure was measured over a 2-wk period using the doubly labeled water technique. Results: The average total energy expenditure of the case subject was 6321 kcal.d(-1). Based on the expected accuracy and precision of the doubly labeled water technique the subject's total energy expenditure might range between 6095 and 6550 kcal.d(-1). The subject's average daily water turnover was 6.083 L over the 14-d period and might range between 5.9 L and 6.3 L.d(-1). Conclusions: This information will provide a guide to the energy requirements of ultra-endurance running and enable athletes, nutritionists, and coaches to optimize performance without compromising the health of the participant.