16 resultados para Patient monitoring
em University of Queensland eSpace - Australia
Resumo:
We reviewed the use of advanced display technologies for monitoring in anesthesia. Researchers are investigating displays that integrate information and that, in some cases, also deliver the results continuously to the anesthesiologist. Integrated visual displays reveal higher-order properties of patient state and speed in responding to events, but their benefits under an intensely timeshared load is unknown. Head-mounted displays seem to shorten the time to respond to changes, but their impact on peripheral awareness and attention is unknown. Continuous auditory displays extending pulse oximetry seem to shorten response times and improve the ability to time-share other tasks, but their integration into the already noisy operative environment still needs to be tested. We reviewed the advantages and disadvantages of the three approaches, drawing on findings from other fields, such as aviation, to suggest outcomes where there are still no results for the anesthesia context. Proving that advanced patient monitoring displays improve patient outcomes is difficult, and a more realistic goal is probably to prove that such displays lead to better situational awareness, earlier responding, and less workload, all of which keep anesthesia practice away from the outer boundaries of safe operation.
Resumo:
We examined the effect of no music, classical music or rock music on simulated patient monitoring. Twenty-four non-anaesthetist participants with high or low levels of musical training were trained to monitor visual and auditory displays of patients' vital signs. In nine anaesthesia test scenarios, participants were asked every 50-70 s whether one of five vital signs was abnormal and the trend of its direction. Abnormality judgements were unaffected by music or musical training. Trend judgements were more accurate when music was playing (p = 0.0004). Musical participants reported trends more accurately (p = 0.004), and non-musical participants tended to benefit more from music than did the musical participants (p = 0.063). Music may provide a pitch and rhythm standard from which participants can judge changes in vital signs from auditory displays. Nonetheless, both groups reported that it was easier to monitor the patient with no music (p = 0.0001), and easier to rely upon the auditory displays with no music (p = 0.014).
Resumo:
We discuss the phenomenon of system tailoring in the context of data from an observational study of anaesthesia. We found that anaesthetists tailor their monitoring equipment so that the auditory alarms are more informative. However, the occurrence of tailoring by anaesthetists in the operating theatre was infrequent, even though the flexibility to tailor exists on many of the patient monitoring systems used in the study. We present an influence diagram to explain how alarm tailoring can increase situation awareness in the operating theatre but why factors inhibiting tailoring prevent widespread use. Extending the influence diagram, we discuss ways that more informative displays could achieve the results sought by anaesthetists when they tailor their alarm systems. In particular, we argue that we should improve our designs rather than simply provide more flexible tailoring systems. because users often find tailoring a complex task. We conclude that properly designed auditory displays may benefit anaesthetists in achieving greater patient situation awareness and that designers should consider carefully how factors promoting and inhibiting tailoring will affect the end-users' likelihood of conducting tailoring. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The idea of sonifying anaesthetised patients’ vital signs is gaining acceptance, but some anaesthetists are concerned about additional noise in the operating theatre. We tested the effect of ambient music (jazz, classical and rock) on participants’ ability to monitor a simulated anaesthetised patient with sonification and visual monitors. Participants liked working with ambient music when workload was low. Participants preferred rock music, but reported working better with classical. Ambient music has less effect on participants’ ability to monitor the simulated patient than a distractor task does. We discuss practical implications of these findings.
Resumo:
The objective of the study was to evaluate whether the introduction of patient-focused nursing care affected the number of seclusions and the length of time patients spent in seclusion, in an acute psychiatric unit. The study used a pre-intervention–post-intervention design and was conducted in an eight-bed locked unit within a large regional general hospital in Queensland, Australia. The medical records of all people who were secluded as part of their management while in hospital, during two 6-month periods, were retrospectively reviewed. Changes to the ways in which nurses conducted their daily activities were implemented during the time between the data collection periods. There were no differences between the groups with respect to the number of times a patient was secluded. However, following implementation of patient-focused care, there was a reduction in the length of time for which patients were secluded. The only change in medication administration was that post-implementation, Haloperidol was used in fewer seclusion episodes. The findings indicate that changes to nursing practice may result in closer monitoring of patients and a reduction in the time patients spend secluded in acute inpatient psychiatric settings.
Resumo:
Aims To determine the cost savings of pharmacist initiated changes to hospitalized patients' drug therapy or management in eight major acute care government funded teaching hospitals in Australia. Methods This was a prospective study performed in eight hospitals examining resource implications of pharmacists' interventions assessed by an independent clinical panel. Pharmacists providing clinical services to inpatients recorded details of interventions, defined as any action that directly resulted in a change to patient management or therapy. An independent clinical review panel, convened at each participating centre, confirmed or rejected the clinical pharmacist's assessment of the impact on length of stay (LOS), readmission probability, medical procedures and laboratory monitoring and quantified the resultant changes, which were then costed. Results A total of 1399 interventions were documented. Eight hundred and thirty-five interventions impacted on drug costs alone. Five hundred and eleven interventions were evaluated by the independent panels with three quarters of these confirmed as having an impact on one or more of: length of stay, readmission probability, medical procedures or laboratory monitoring. There were 96 interventions deemed by the independent panels to have reduced LOS and 156 reduced the potential for readmission. The calculated savings was $263 221 for the eight hospitals during the period of the study. This included $150 307 for length of stay reduction, $111 848 for readmission reduction. Conclusions The annualized cost savings relating to length of stay, readmission, drugs, medical procedures and laboratory monitoring as a result of clinical pharmacist initiated changes to hospitalized patient management or therapy was $4 444 794 for eight major acute care government funded teaching hospitals in Australia.
Resumo:
Marathon running is growing in popularity, and many diabetic patients are participating in various marathon races all over the world each year. This study aimed to investigate the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) during a marathon run in patients with well-controlled diabetes mellitus using a continuous glucose monitoring system (CGMS). Five subjects with type 1 and one patient with type 2 diabetes mellitus were monitored with the Medtronic MiniMed CGMS during the 2002 Vienna City Marathon (n = 3) or the Fernwarme run (n = 3) long distance runs of 42.19/15.8 km. All six patients finished their course. The CGSM system was well tolerated in all patients over an average duration of 34 +/- 4.0 hours and it did not limit the patients' activities. The mean running time for the Vienna city marathon was 257 +/- 8 min (247 to 274 min) and for the Fernwarme run 134 +/- 118 min (113 to 150 min). A total of 1470 blood glucose measurements (mean 245 readings per subject) were performed. During and after the marathons frequent hypo and hyperglycemic episodes with and without clinical symptoms were measured. Our data confirm that the CGMS may help to identify asymptomatic hypoglycemia or hyperglycemia during and after a long distance run. The system may also be helpful to improve our understanding about the individual changes of glucose during and after a marathon and may protect hypoglycemic or hyperglycemic periods in future races.
Resumo:
This report describes the case of an 88-year-old non-diabetic female who presented to the emergency department following a presumed hypoijtycaemic collapse due to self-neglect. Subsequent rewarming and resuscitation demonstrated a number of the significant consequences of severe hypothermia, including apparent secondary impairment of glycaemic autoregulation. The phenomenon of reversible inhibition of insulin secretion due to severe hypothermia has been documented previously in the field of cardiac surgery. The hyperglycaemia was not treated with any antihyperglycaernic agent, and her recovery was uneventful. Subsequent blood sugar level monitoring was normal. If insulin is administered to the hypothermic patient, intensive monitoring of blood glucose is essential due to the increase in endogenous insulin secretion on rewarming. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
Resumo:
A vision of the future of intraoperative monitoring for anesthesia is presented-a multimodal world based on advanced sensing capabilities. I explore progress towards this vision, outlining the general nature of the anesthetist's monitoring task and the dangers of attentional capture. Research in attention indicates different kinds of attentional control, such as endogenous and exogenous orienting, which are critical to how awareness of patient state is maintained, but which may work differently across different modalities. Four kinds of medical monitoring displays are surveyed: (1) integrated visual displays, (2) head-mounted displays, (3) advanced auditory displays and (4) auditory alarms. Achievements and challenges in each area are outlined. In future research, we should focus more clearly on identifying anesthetists' information needs and we should develop models of attention in different modalities and across different modalities that are more capable of guiding design. (c) 2006 Elsevier Ltd. All rights reserved.