65 resultados para Passive MVC
em University of Queensland eSpace - Australia
Resumo:
Skin penetration of the tetrapeptide Ac-Ala-Ala-Pro-Val-NH2 was assessed. This peptide sequence fits the P-P-1 subsites of elastase and inhibits human neutrophil elastase competitively. Consequently this peptide may be therapeutically useful in a variety of inflammatory disorders, including psoriasis. in which elevated levels of human neutrophil elastase have been reported. Peptide penetration was assessed across whole human skin, whole skin with the stratum corneum removed by tape stripping and epidermis, which had been removed from the dermis by heat separation. The influence of 75% aqueous ethanol as a potential penetration enhancer of the tetrapeptide across epidermis was also assessed. The tetrapeptide did not penetrate whole human skin or epidermis, even under the influence of 75% aqueous ethanol. However, when the stratum corneum was removed tetrapeptide flux of 73.39 mug cm(-2) h(-1) was achieved. The study demonstrates that the stratum corneum is the main barrier to tetrapeptide skin penetration and must be overcome if therapeutically relevant amounts of tetrapeptide are to be delivered to the skin.
Resumo:
Background: Although immunization with tumor antigens can eliminate many transplantable tumors in animal models, immune effector mechanisms associated with successful immunotherapy of epithelial cancers remain undefined. Methods: Skin from transgenic mice expressing the cervical cancer-associated tumor antigen human papillornavirus type 16 (HPV16) E6 or E7 proteins from a keratin 14 promoter was grafted onto syngeneic, non-transgenic mice. Skin graft rejection was measured after active immunization with HPV16 E7 and adoptive transfer of antigen-specific T cells. Cytokine secretion of lymphocytes from mice receiving skin grafts and immunotherapy was detected by enzyme-linked immunosorbent assay, and HPV16 E7-specific memory CD8(+) T cells were detected by flow cytometry and ELISPOT. Results: Skin grafts containing HPV16 E6- or E7-expressing keratinocytes were not rejected spontaneously or following immunization with E7 protein and adjuvant. Adoptive transfer of E7-specific T-cell receptor transgenic CD8(+) T cells combined with immunization resulted in induction of antigen-specific interferon gamma-secreting CD8(+) T cells and rejection of HPV16 E7-expressing grafts. Specific memory CD8(+) T cells were generated by immunotherapy. However, a further HPV16 E7 graft was rejected from animals with memory T cells only after a second E7 immunization. Conclusions: Antigen-specific CD8(+) T cells can destroy epithelium expressing HPV16 E7 tumor antigen, but presentation of E7 antigen from skin is insufficient to reactivate memory CD8(+) T cells induced by immunotherapy. Thus, effective cancer immunotherapy in humans may need to invoke sufficient effector as well as memory T cells.
Resumo:
Semipermeable membrane devices (SPMDs) have been used as passive air samplers of semivolatile organic compounds in a range of studies. However, due to a lack of calibration data for polyaromatic hydrocarbons (PAHs), SPMD data have not been used to estimate air concentrations of target PAHs. In this study, SPMDs were deployed for 32 days at two sites in a major metropolitan area in Australia. High-volume active sampling systems (HiVol) were co-deployed at both sites. Using the HiVol air concentration data from one site, SPMD sampling rates were measured for 12 US EPA Priority Pollutant PAHs and then these values were used to determine air concentrations at the second site from SPMD concentrations. Air concentrations were also measured at the second site with co-deployed HiVols to validate the SPMD results. PAHs mostly associated with the vapour phase (Fluorene to Pyrene) dominated both the HiVol and passive air samples. Reproducibility between replicate passive samplers was satisfactory (CV < 20%) for the majority of compounds. Sampling rates ranged between 0.6 and 6.1 m(3) d(-1). SPMD-based air concentrations were calculated at the second site for each compound using these sampling rates and the differences between SPMD-derived air concentrations and those measured using a HiVol were, on average, within a factor of 1.5. The dominant processes for the uptake of PAHs by SPMDs were also assessed. Using the SPMD method described herein, estimates of particulate sorbed airborne PAHs with five rings or greater were within 1.8-fold of HiVol measured values. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Passive electroreception is a complex and specialised sense found in a large range of aquatic vertebrates primarily designed for the detection of weak bioelectric fields. Particular attention has traditionally focused on cartilaginous fishes, but a range of teleost and non-teleost fishes from a diversity of habitats have also been examined. As more species are investigated, it has become apparent that the role of electroreception in fishes is not restricted to locating prey, but is utilised in other complex behaviours. This paper presents the various functional roles of passive electroreception in non-electric fishes, by reviewing much of the recent research on the detection of prey in the context of differences in species' habitat (shallow water, deep-sea, freshwater and saltwater). A special case study on the distribution and neural groupings of ampullary organs in the omnihaline bull shark, Carcharhinus leucas, is also presented and reveals that prey-capture, rather than navigation, may be an important determinant of pore distribution. The discrimination between potential predators and conspecifics and the role of bioelectric stimuli in social behaviour is discussed, as is the ability to migrate over short or long distances in order to locate environmentally favourable conditions. The various theories proposed regarding the importance and mediation of geomagnetic orientation by either an electroreceptive and/or a magnetite-based sensory system receives particular attention. The importance of electroreception to many species is emphasised by highlighting what still remains to be investigated, especially with respect to the physical, biochemical and neural properties of the ampullary organs and the signals that give rise to the large range of observed behaviours.
Resumo:
The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K-SV) when air-side resistance dominates and increase with K-SV when sampler-side resistance dominates.
Resumo:
An investigation was carried out on the transition of an iron electrode from active to passive state in a sulphuric acid solution. It was found that the active-passive transition was an auto-catalytic process in which a pre-passive film grew on the electrode surface. The growing pre-passive film had a fractal edge whose dimension was affected by the applied passivating potential and the presence of chlorides in the solution. Applying a more positive passivating potential led to a faster active-passive transition and resulted in a more irregular pre-passive film. If chlorides were introduced into the sulphuric acid solution, the active-passive transition became more rapid and the pre-passive film more irregular. Apart from the influence on the growth of the pre-passive film, the presence of chlorides in the passivating solution was found to deteriorate the stability of the final passive film. All these phenomena can be understood if the passivating iron electrode is regarded as a dissipative system. To explain these results, a fractal pre-film model is proposed in this paper. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Background/aims: Clinical and laboratory studies are consistent with a major role for cell-mediated immunity in recovery from oral infection with Candida albicans, but the role of humoral immunity remains controversial. The purpose of this study was to establish the relative contributions of cellular and humoral immunity to protection against oral candidiasis in a murine model, and to determine whether host responses could be enhanced by different immunization strategies. Results: Active oral immunization was protective in BALB/c and CBA/CaH mice, reducing both fungal burden and duration of infection after secondary challenge, whereas systemic immunization failed to protect against subsequent oral challenge. Candida-specific IgM was the predominant antibody detected in serum following both primary and secondary oral challenge; however, Candida-specific salivary IgA was not detectable. Immunization by passive transfer of either lymphocytes or immune serum did not confer any significant protection against oral infection in either susceptible or resistant mouse strain. Conclusion: The data demonstrate a possible role for mucosa-associated immunity following active immunization by the oral route, most likely exerted by local T lymphocytes resident in the oral mucosa, but there was no evidence to support a role for humoral immunity in protection against oral candidiasis.
Resumo:
The proximity of the Great Barrier Reef (GBR) Marine Park to areas of intensive agriculture and increasing urbanisation places the park under potential threat of contamination by land-based pollutants. Passive samplers were deployed at inshore reef and river mouth sites in the Wet Tropics region of the GBR during a dry and a wet season to measure levels of land-based organic pollutants in this environment. Two types of passive sampling devices were deployed: (i) a polar sampler, which can be used to monitor polar herbicides and (ii) semipermeable membrane devices (SPMDs) which sequester more hydrophobic compounds (e.g. PAHs, chlorpyrifos). Herbicides (diuron, simazine, atrazine, hexazinone and/or flumeturon) were detected at low concentrations (ng L-1) at all sites sampled and in both seasons. Chlorpyrifos was not detected while PAHs were present in SPMDs at levels below limits of detection. The results show that the GBR environment does contain low levels of organic pollutants and that passive sampling provides a sensitive monitoring tool for measuring waterborne organic pollutants. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Water-sampler equilibrium partitioning coefficients and aqueous boundary layer mass transfer coefficients for atrazine, diuron, hexazionone and fluometuron onto C18 and SDB-RPS Empore disk-based aquatic passive samplers have been determined experimentally under a laminar flow regime (Re = 5400). The method involved accelerating the time to equilibrium of the samplers by exposing them to three water concentrations, decreasing stepwise to 50% and then 25% of the original concentration. Assuming first-order Fickian kinetics across a rate-limiting aqueous boundary layer, both parameters are determined computationally by unconstrained nonlinear optimization. In addition, a method of estimation of mass transfer coefficients-therefore sampling rates-using the dimensionless Sherwood correlation developed for laminar flow over a flat plate is applied. For each of the herbicides, this correlation is validated to within 40% of the experimental data. The study demonstrates that for trace concentrations (sub 0.1 mu g/L) and these flow conditions, a naked Empore disk performs well as an integrative sampler over short deployments (up to 7 days) for the range of polar herbicides investigated. The SDB-RPS disk allows a longer integrative period than the C18 disk due to its higher sorbent mass and/or its more polar sorbent chemistry. This work also suggests that for certain passive sampler designs, empirical estimation of sampling rates may be possible using correlations that have been available in the chemical engineering literature for some time.
Resumo:
Background: Costs of tobacco-related disease can be useful evidence to support tobacco control. In Hong Kong we now have locally derived data on the risks of smoking, including passive smoking. Aim: To estimate the health-related costs of tobacco from both active and passive smoking. Methods: Using local data, we estimated active and passive smoking-attributable mortality, hospital admissions, outpatient, emergency and general practitioner visits for adults and children, use of nursing homes and domestic help, time lost from work due to illness and premature mortality in the productive years. Morbidity risk data were used where possible but otherwise estimates based on mortality risks were used. Utilisation was valued at unit costs or from survey data. Work time lost was valued at the median wage and an additional costing included a value of US$1.3 million for a life lost. Results: In the Hong Kong population of 6.5 million in 1998, the annual value of direct medical costs, long term care and productivity loss was US$532 million for active smoking and US$156 million for passive smoking; passive smoking accounted for 23% of the total costs. Adding the value of attributable lives lost brought the annual cost to US$9.4 billion. Conclusion: The health costs of tobacco use are high and represent a net loss to society. Passive smoking increases these costs by at least a quarter. This quantification of the costs of tobacco provides strong motivation for legislative action on smoke-free areas in the Asia Pacific Region and elsewhere.
Resumo:
Polyethylene-based passive air samplers (PSDs) were loaded with performance reference compounds (PRCs) and deployed in a wind tunnel to examine the effects of wind speed on sampler performance. PRCs could be loaded reproducibly into PSDs, with coefficients of variation only exceeding 20% for the more volatile compounds. When PSDs were exposed to low (0.5-1.5 m s(-1)) and high (3.5-4.5 m s(-1)) wind speeds, PRC loss rate constants generally increased with increasing wind speed and decreased with increasing sampler/air partition coefficients. PSD-based air concentrations calculated using PRC loss rate constants and sampler/air partition coefficients and air concentrations measured using active samplers compared closely. PRCs can be used to account for the effect of differences in wind speeds on sampler performance and measure air concentrations with reasonable accuracy. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to evaluate the feasibility of using semipermeable membrane devices (SPMDs) and polyethylene-based passive sampler devices (PSDs) for monitoring PAHs in stormwater. Firstly, SPMDs were deployed at one site and SPMD-derived water concentrations were compared with water concentration measured from grab samples. In a subsequent deployment the performance of SPMDs and PSDs was compared. Finally PSDs of multiple surface area to volume ratios were used to compare PAH concentrations at the two sites. The results obtained in this study show that SPMDs can be used to measure the water concentration of PAHs with reasonable accuracy, when compared with grab samples collected at the same site. Importantly, several PAHs which could not be detected in a 10 L grab sample could be detected in the SPMDs. PSD and SPMD samplers produced similar results when deployed at the same site, with most estimated water concentrations within a factor of 1.5. The use of PSDs in multiple surface area to volume ratios proved to be an effective means of characterizing the uptake kinetics for PAHs in situ. Overall passive water samplers proved to be an efficient technique for monitoring PAHs in stormwater.