5 resultados para Oxygen-saturation

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of maternal epidural analgesia in labor may be associated with nonreassuring fetal heart rate (FHR) patterns. Fetal oxygen saturation (FSpO(2)) monitoring may improve assessment of fetal well-being during this time. Mean FSpO(2) values were compared over seven 5-minute epochs: 5 minutes prior to an epidural event (combined insertion of epidural/top-up epidural analgesia and infusion pump bolus), to 30 minutes following the event, including possible effects of maternal position and FHR pattern on FSpO(2) values. Mean FSpO(2) values were significantly different between the 5 minutes prior (49.5%) versus 16-20 minutes (44.3%, p

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thirteen intubated, high dependency patients with neurological injuries were studied in order to investigate the short term respiratory effects of neurophysiological facilitation and passive movement on tidal volume (V-T), minute ventilation (V-E), respiratory rate (V-R) and oxygen saturation (SpO(2)). The subjects were studied under four conditions: no intervention (control) and during periods of neurophysiological facilitation, passive movement and sensory stimulation. All periods were standardised to three minutes duration and all parameters were recorded before and after each intervention. Neurophysiological facilitation produced significant increases (p < 0.01) in V-E and SpO(2) (p < 0.05) when compared with control values, with an overall mean increase in V-E of 14.6%. Similarly, passive movement increased V-E (p < 0.01) by an average of 9.8% and also increased SpO(2) (p < 0.01). In contrast, sensory stimulation produced significant increases (p < 0.01) in SpO(2) with control levels, with no significant change in V-T or V-E. There was no significant difference in V-R with all treatments. This study provides preliminary evidence of improved short term ventilatory function following neurophysiological facilitation, independent of generalised sensory stimulation, which has not been previously examined in the literature, supporting its use in the management of high dependency neurological patients.