5 resultados para Orthopedic prostheses

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: This study aims to address medical and non-medical direct costs and health outcomes of bilateral and unilateral total knee replacement from the patients' perspective during the first year post-surgery. Methods: Osteoarthritis patients undergoing primary unilateral total knee or bilateral total knee replacement (TKR) surgery at three Sydney hospitals were eligible. Patients completed questionnaires pre-operatively to record expenses during the previous three months and health status immediately prior to surgery. Patients then maintained detailed prospective cost diaries and completed SF-36 and WOMAC Index each three months for the first post-operative year. Results: Pre-operatively, no significant differences in health status were found between patients undergoing unilateral TKR and bilateral TKR. Both unilateral and bilateral TKR patients showed improvements in pain, stiffness and function from pre-surgery to 12 months post-surgery. Patients who had bilateral TKR spent an average of 12.3 days in acute hospital and patients who had unilateral TKR 13.6 days. Totally uncemented prostheses were used in 6% of unilateral replacements and 48% of bilateral replacements. In hospital, patients who had bilateral TKR experienced significantly more complications, mainly thromboembolic, than patients who had unilateral TKR. Regression analysis showed that for every one point increase in the pre-operative SF-36 physical score (i.e. improving physical status) out-of-pocket costs decreased by 94%. Out-of-pocket costs for female patients were 3.3 times greater than for males. Conclusion: Patients undergoing bilateral TKR and unilateral TKR had a similar length of stay in hospital and similar out-of-pocket expenditures. Bilateral replacement patients reported better physical function and general health with fewer health care visits one year post procedure. Patients requiring bilateral TKR have some additional information to aid their decision making. While their risk of peri-operative complications is higher, they have an excellent chance of good health outcomes at 12 months and are not going to be doubly 'out-of-pocket' for the experience. (C) 2004 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion. The new Provox(R) NID (TM) non- indwelling voice prosthesis investigated in this study provides a good option for laryngectomized patients using non- indwelling voice prostheses and can potentially improve safety and increase patients' satisfaction with their voice and speech. Objective. To investigate the feasibility of and patient satisfaction with the Provox NID non- indwelling voice prosthesis. Material and methods. Pre- and post- study questionnaires were used to evaluate the patients' former voice prosthesis and the Provox NID voice prosthesis. In addition, measurements of pull- out force, maximum phonation time and loudness were made for both voice prostheses. In vitro measurements of airflow characteristics were also made. Following a 6- week trial, all patients provided feedback on the new voice prosthesis and the results were used to further improve the Provox NID. This final version of the new voice prosthesis was subsequently trialled and evaluated by 10 patients 6 months later. Results. Overall results showed that patient satisfaction with the Provox NID non- indwelling voice prosthesis was favourable. The pull- out force for the new prosthesis was significantly higher than that for the formerly used prosthesis and its aerodynamic characteristics were better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon nanotubes (CNT) are well-ordered, high aspect ratio allotropes of carbon. The two main variants, single-walled carbon nanotubes (SWCNT) and multi-walled carbon nanotubes (MWCNT) both possess a high tensile strength, are ultra-light weight, and have excellent chemical and thermal stability. They also possess semi- and metallic-conductive properties. This startling array of features has led to many proposed applications in the biomedical field, including biosensors, drug and vaccine delivery and the preparation of unique biomaterials such as reinforced and/or conductive polymer nanocomposites. Despite an explosion of research into potential devices and applications, it is only recently that information on toxicity and biocompatibility has become available. This review presents a summary of the performance of existing carbon biomaterials and gives an outline of the emerging field of nanotoxicology, before reviewing the available and often conflicting investigations into the cytotoxicity and biocompatibility of CNT. Finally, future areas of investigation and possible solutions to current problems are proposed. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mild traumatic brain injury (mTBI) is a common injury and a significant proportion of those affected report chronic symptoms. This study investigated prediction of post-concussion symptoms using an Emergency Department (ED) assessment that examined neuropsychological and balance deficits and pain severity of 29 concussed individuals. Thirty participants with minor orthopedic injuries and 30 ED visitors were recruited as control subjects. Concussed and orthopedically injured participants were followed up by telephone at one month to assess symptom severity. In the ED, concussed subjects performed worse on some neuropsychological tests and had impaired balance compared to controls. They also reported significantly more post-concussive symptoms at follow-up. Neurocognitive impairment, pain and balance deficits were all significantly correlated with severity of post-concussion symptoms. The findings suggest that a combination of variables assessable in the ED may be useful in predicting which individuals will suffer persistent post-concussion problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultra wideband (UWB) radar has been extensively investigated both theoretically and practically for the identification buried artifacts. Ground probe radar (GPR) concentrates on the identification of lightly buried land mines, unexploded ordnance (UXO) and archeological targets. The same technology is proposed in a similar context for the rapid identification of in vivo implanted metallic prostheses. The technique is based on resonance based target identification and the paper investigates UWB scattering from a metallic hip prosthesis in free space as a first step in the identification process.