41 resultados para Orthodontic-wire

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A versatile miniature de Broglie waveguide is formed by two parallel current-carrying wires in the presence of a uniform bias field. We derive a variety of analytical expressions to describe the guide and present a quantum theory to show that it offers a remarkable range of possibilities for atom manipulation on the submicron scale. These include controlled and coherent splitting of the wave function as well as cooling, trapping, and guiding. In particular, we discuss a novel microscopic atom interferometer with the potential to be exceedingly sensitive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the statistical properties of the local density of states of a one-dimensional Dirac equation in the presence of various types of disorder with Gaussian white-noise distribution. It is shown how either the replica trick or supersymmetry can be used to calculate exactly all the moments of the local density of states.' Careful attention is paid to how the results change if the local density of states is averaged over atomic length scales. For both the replica trick and supersymmetry the problem is reduced to finding the ground state of a zero-dimensional Hamiltonian which is written solely in terms of a pair of coupled spins which are elements of u(1, 1). This ground state is explicitly found for the particular case of the Dirac equation corresponding to an infinite metallic quantum wire with a single conduction channel. The calculated moments of the local density of states agree with those found previously by Al'tshuler and Prigodin [Sov. Phys. JETP 68 (1989) 198] using a technique based on recursion relations for Feynman diagrams. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone remodeling during tooth movement is regulated by local and systemic factors. Two regulators of bone metabolism are growth hormone (GH) and insulin-like growth factor-I (IGF-1). Their effects are mediated via binding to GH receptor (GHR) and IGF-I receptor (IGF-IR) in target tissues. Corticosteroids may affect the activity of these growth factors. This study examined the effect of prednisolone on GHR and IGF-IR expression in dental tissues following orthodontic tooth movement. The corti ticosteroid-treated group (N = 6) was administered prednisolone ( 1 mg/kg,) daily and the control group (N = 6) received equivalent volumes of saline. An orthodontic force (30 g) was applied to the maxillary first molar. Animals were sacrificed 12 days postappliance insertion. Sagittal sections of the first molar were stained for GHR and IGF-IR immunoreactivity. GHR and IGF-IR cell counts were elevated following appliance-treatment. Orthodontic tooth movement appeared to up-regulate GHR and IGF-IR immunoreactivity, but this up-regulation was reduced following prednisolone treatment. The suppression of GHR and IGF-I immunoreactivity in steroid-treated animals infers the mechanism whereby bone resorption and deposition, necessary for orthodontic tooth movement, may be inhibited by prednisolone. However, at 12 days postappliance insertion. no difference in orthodontic tooth movement was observed following low-dose prednisolone treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hot-wire anemometers at low operating currents are used as fast response resistance thermometers for the study of heated turbulent flows. Simultaneous measurement of temperature and velocity is generally performed with multi-wire arrays. In order to give good spatial resolution a new layout has been tested which uses an inclined temperature wire positioned parallel to the nearest inclined velocity wire. This leads to an asymmetric wire arrangement relative to the mean flow direction. As expected, a reduction in thermal interference from the velocity wires results when compared with an array containing a temperature wire placed normal to the flow. However, measurement of higher order moments of fluctuating quantities in an axisymmetric jet shows considerable distortion of radial distributions which is traced to alteration of the temperature field sensed by the temperature wire. When inclined velocity sensitive wires contain a temperature component, the latter may be affected by the same phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Previous studies of stability and relapse after orthodontic treatment report short-term stability is generally followed by slow relapse to the original condition. What these studies do not report is whether this relapse is continuous or interspersed with periods of improvement or stability. Methods: A subjective 0-10 index of malocclusion was used to record post-treatment stability and relapse over 10 to 12 years following fixed appliance orthodontic treatment of 24 patients. The severity scores were plotted on timelines. Results: Episodes of change, both favourable and unfavourable, were interspersed with episodes of stability. Conclusions: Changes in the first 3 and 12 months post-treatment are indicative of the 10 to 12 years post-treatment outcomes. This index may provide a useful instrument to analyze patients and/or their study models longitudinally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Most patients and their parents experience difficulty in fully appreciating the implications and demands of orthodontic treatment. This is largely because of inadequate understanding of the process of treatment or the commitment required. OBJECTIVES: To determine if a specifically developed video information package could significantly increase patient awareness of the implications of a full course of orthodontic treatment. Changes in attitude to orthodontic treatment after viewing the package were also measured. METHODS: Year 7 (12 year-old) students in two primary schools in the City of Gold Coast, Australia were randomly allocated to either a study group or a control group. Knowledge of and attitude to orthodontic treatment were measured with self-administered questionnaires before and after viewing the information package. RESULTS: The intervention group showed a 15 per cent gain in knowledge (p < 0.001). There was no gain in knowledge for the 45 students in the control group. There was no measured change in perception of need for orthodontic treatment in the study group. There was, however, an increase in potential compliance and positive attitude to the appearance of orthodontic appliances. There was a small increase in willingness to undertake treatment, but this was not statistically significant. CONCLUSIONS: The information package developed for this study increased awareness of the implications and practical difficulties which may be encountered during a course of orthodontic treatment, and produced some changes in attitude to treatment.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adverse effects of corticosteroids on bone metabolism raise concerns as to whether steroid treatment may influence orthodontic movement. This study examined the effect of prednisolone on orthodontic movement using an established rat model. The corticosteroid treated group (N = 6) was administered prednisolone (1 mg/kg) daily, for a 12-day induction period; the control group (N = 6) received equivalent volumes of saline. On day 12, an orthodontic appliance was placed which exerted 30 g of mesial force to the maxillary first molar. Animals were sacrificed on day 24 and tooth movement was measured. Sagittal sections of the molars were stained with haematoxylin and eosin, and for tartrate-resistant acid phosphatase (TRAP) activity. While there were no significant differences in the magnitude of tooth movement between the 2 groups, steroid-treated rats displayed significantly less root resorption on the compression side and fewer TRAP-positive cells within the PDL space on the same side. This suggests steroid treatment suppressed elastic activity.