116 resultados para Operating-theater
em University of Queensland eSpace - Australia
Resumo:
We examined the effect of no music, classical music or rock music on simulated patient monitoring. Twenty-four non-anaesthetist participants with high or low levels of musical training were trained to monitor visual and auditory displays of patients' vital signs. In nine anaesthesia test scenarios, participants were asked every 50-70 s whether one of five vital signs was abnormal and the trend of its direction. Abnormality judgements were unaffected by music or musical training. Trend judgements were more accurate when music was playing (p = 0.0004). Musical participants reported trends more accurately (p = 0.004), and non-musical participants tended to benefit more from music than did the musical participants (p = 0.063). Music may provide a pitch and rhythm standard from which participants can judge changes in vital signs from auditory displays. Nonetheless, both groups reported that it was easier to monitor the patient with no music (p = 0.0001), and easier to rely upon the auditory displays with no music (p = 0.014).
Resumo:
Many cases of potentially curable primary aldosteronism are currently likely to be diagnosed as essential hypertension unless screening tests based on suppression of renin are tarried out in all hypertensive patients. More than half of the patients with primary aldosteronism detected in this way have normal circulating potassium levels, so measurement of potassium is not enough to exclude primary aldosteronism. When primary aldosteronism is diagnosed, fewer than one-third of patients are suitable for surgery as initial treatment, but this still represents a significant percentage of hypertensive patients. After excluding glucocorticoid-suppressible primary aldosteronism, adrenal venous sampling is essential to detect unilateral production of aldosterone and diagnose angiotensin-responsive aldosterone-producing adenoma. One cannot rely on the computed tomography scan. If all hypertensive patients are screened for primary aldosteronism and the workup is continued methodically in those with a positive screening test, patients with unilateral overproduction of aldosterone who potentially can be cured surgically are not denied the possibility of cure.
Resumo:
Recent years have seen the introduction of new and varied designs of activated sludge plants. With increasing needs for higher efficiencies and lower costs, the possibility of a plant that operates more effectively has created the need for tools that can be used to evaluate and compare designs at the design stage. One such tool is the operating space diagram. It is the aim of this paper to present this tool and demonstrate its application and relevance to design using a simple case study. In the case study, use of the operating space diagram suggested changes in design that would improve the flexibility of the process. It also was useful for designing suitable control strategies.
Resumo:
This paper presents a metafrontier production function model for firms in different groups having different technologies. The metafrontier model enables the calculation of comparable technical efficiencies for firms operating under different technologies. The model also enables the technology gaps to be estimated for firms under different technologies relative to the potential technology available to the industry as a whole. The metafrontier model is applied in the analysis of panel data on garment firms in five different regions of Indonesia, assuming that the regional stochastic frontier production function models have technical inefficiency effects with the time-varying structure proposed by Battese and Coelli ( 1992).
Resumo:
The central composite rotatable design (CCRD) was used to design an experimental program to model the effects of inlet pressure, feed density, and length and diameter of the inner vortex finder on the operational performance of a 150-min three-product cyclone. The ranges of values of the variables used in the design were: inlet pressure: 80-130 kPa, feed density: 30 60%; length of IVF below the OVF: 50-585 mm; diameter of IVF: 35-50 mm. A total of 30 tests were conducted, which is 51 less; an that required for a three-level full factorial design. Because the model allows confident performance prediction by interpolation over the range of data in the database, it was used to construct response surface graphs to describe the effects of the variables on the performance of the three-product cyclone. To obtain a simple and yet a realistic model, it was refitted using only the variable terms that are significant at greater than or equal to 90% confidence level. Considering the selected operating variables, the resultant model is significant and predicts the experimental data well. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
This paper introduces a method for power system modeling during the earth fault. The possibility of using this method for selection and adjustment of earth fault protection is pointed out. The paper also contains the comparison of results achieved by simulation with the experimental measurements.
Operation of polymer electrolyte membrane fuel cells with dry feeds: Design and operating strategies
Resumo:
The operation of polymer electrolyte membrane fuel cells (PEMFCs) with dry feeds has been examined with different fuel cell flow channel designs as functions of pressure, temperature and flow rate. Auto-humidified (or self-humidifying) PEMFC operation is improved at higher pressures and low gas velocities where axial dispersion enhances back-mixing of the product water with the dry feed. We demonstrate auto-humidified operation of the channel-less, self-draining fuel cell, based on a stirred tank reactor; data is presented showing auto-humidified operation from 25 to 115 degrees C at 1 and 3 atm. Design and operating requirements are derived for the auto-humidified operation of the channel-less, self-draining fuel cell. The auto-humidified self-draining fuel cell outperforms a fully humidified serpentine flow channel fuel cell at high current densities. The new design offers substantial benefits for simplicity of operation and control including: the ability to self-drain reducing flooding, the ability to uniformly disperse water removing current gradients and the ability to operate on dry feeds eliminating the need for humidifiers. Additionally, the design lends itself well to a modular design concept. (c) 2005 Elsevier B.V. All rights reserved.