9 resultados para Neonatal Hearing Screening
em University of Queensland eSpace - Australia
Resumo:
The primary aim of the present study was to investigate parent satisfaction with a neonatal hearing screening program through use of a valid and reliable questionnaire developed for this purpose (Parent Satisfaction Questionnaire with Neonatal Hearing Screening Program; PSQ-NHSP). Eighty parents whose children had received hearing screening participated in this study. High levels of satisfaction were reported with more than 90% of parents satisfied with all aspects of the program. The PSQ-NHSP was analyzed for validity and reliability and demonstrated excellent internal consistency reliability (sigma = 0.94) and excellent test-retest reliability (rho = 0.97). Content validity of the PSQ-NHSP was partially established by reviewing available literature on parent satisfaction studies in other pediatric health-care service programs. Construct validity of the PSQ-NHSP was indicated by a significant positive relationship between overall satisfaction and the three specific dimensions in the questionnaire. The satisfaction questionnaire was found to be a useful instrument for identifying service shortfalls, and routine use of the PSQ-NHSP in other neonatal hearing screening programs is recommended.
Resumo:
We have examined the feasibility of a telemedicine-enabled screening service for children and adolescents with diabetes in Queensland. There are approximately 1400 young people with diabetes in Queensland and only about two-thirds of them are screened in accordance with international guidelines. A regional retinal screening service was established using a non-mydriatic digital retinal camera. Seven centres volunteered to participate in the study. During a five-month pilot trial, 83 of the young people with diabetes who attend these centres underwent digital retinal screening (3.7%). Retinal images were sent via email to a paediatric ophthalmologist for review and results were returned via email. A copy of each participant's results was forwarded by mail to the referring diabetes doctor and the participant and family. The majority of the image files (96%) were rated as excellent or good. Only one participant was identified as having an abnormal result. Participants and their families expressed satisfaction with the digital retinal screening process.
Resumo:
We present the clinical and ophthalmological findings in two infants with neonatal Marfan syndrome (nMFS) and primary trabeculodysgenesis (PT). Fibrillin 1 (FBN1) mutations were confirmed in both cases. Numerous eye anomalies have been recognized in infants with nMFS, but PT has not been reported previously. Our report expands the phenotype of nMFS, and highlights the importance of early and careful ophthalmological assessment of these infants. (C) 2004 Wiley-Liss, Inc.
Resumo:
Aim: Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited reliable screening tests for both central (CE) and obstructive (OE) respiratory events. This study compared three indices, derived from pulse oximetry and electrocardiogram ( ECG), with the PSG gold standard. These indices were heart rate (HR) variability, arterial blood oxygen de-saturation (SaO(2)) and pulse transit time (PTT). Methods: 15 children (12 male) from routine PSG studies were recruited (aged 3 - 14 years). The characteristics of the three indices were based on known criteria for respiratory events (RPE). Their estimation singly and in combination was evaluated with simultaneous scored PSG recordings. Results: 215 RPE and 215 tidal breathing events were analysed. For OE, the obtained sensitivity was HR (0.703), SaO(2) (0.047), PTT (0.750), considering all three indices (0) and either of the indices (0.828) while specificity was (0.891), (0.938), (0.922), (0.953) and (0.859) respectively. For CE, the sensitivity was HR (0.715), SaO(2) (0.278), PTT (0.662), considering all indices (0.040) and either of the indices (0.868) while specificity was (0.815), (0.954), (0.901), (0.960) and (0.762) accordingly. Conclusions: Preliminary findings herein suggest that the later combination of these non-invasive indices to be a promising screening method of SDB in children.
Resumo:
Screening measures of cognitive status are traditionally administered face to face. In survey research such screening mcasurcs, while desirable, must he administered by other means. As part of pilot survey research on a New Zealand war veteran population with some degree of hearing impairment, a face-to-face administration of the Mini-Mental State Examination (MMSE; Folstein, Folstein and McHugh, 1975) and a telephoneadministration of the Telephonc Interview for Cognitive Status (TICS; Brandt, Spencer and Folstein. 1988) were compared. Brandt ('/ u/. (1988) reported a very strong linear relationship between scores on the MMSE and the TICS (r=0.94, p < .0001) in an Alzheimer patient population with a mcan MMSE score of 12.06 (6.78). For a sample of 44 mildly to moderately hearing impaired veterans, with a mean MMSE score of 25.52 (2.16) and a mean TICS score of 32.52(5.43), the correlation between the instruments was .39. When veterans who wore hearing aids during the telephone interview ( N = 2 2 ) wcrc separated out from those who did not, the correlation rose to .54. Age was ncgatively correlated with the MMSE ( r = -0.41, / I < .01) and not significantly correlated with the TICS. Education level was unrelated to either measure. The data suggest that the wearing or non-wearing of hearing aids may contribute significantly to the reliability of the TICS. Furthermore, on non-demented populations with a less restricted range of scores. the correlation of the MMSE and TICS may he lower than previously reported.