3 resultados para Muscle stimulation

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical muscle stimulation (EMS) devices are being marketed as weight/ fat loss devices throughout the world. Commercially available stimulators have the ability to evoke muscle contractions that may affect caloric expenditure while the device is being used. The aim of this study was to test the effects of two different EMS devices (Abtronic and Feminique) on oxygen consumption at rest. Subjects arrived for testing after an overnight fast, had the devices fitted, and then positioned supine with expired air measured to determine oxygen consumption. After a 10-minute acclimation period, oxygen consumption was measured for 20 minutes with the device switched off (resting) then 20 minutes with the device switched on (stimulated). There were no significant differences (P > 0.05) in oxygen consumption between the resting and stimulated periods with either the Abtronic (mean SD; resting, 3.40 +/- 0.44; stimulated, 3.45 +/- 0.53 ml of O-2.kg(-1).min(-1)) or the Feminique (resting, 3.73 +/- 0.45; stimulated, 3.75 +/- 0.46 ml of O-2.kg(-1).min(-1)). In summary, the EMS devices tested had no effect on oxygen consumption during muscle stimulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Patella taping reduces pain ill individuals with patellofemoral pain (PFP), although the mechanism remains unclear. One possibility is that patella taping modifies vasti muscle activity via stimulation of cutaneous afferents. The aim of this study was to investigate the effect of stretching the skin over the patella on vasti Muscle activity in people with PFP. Electromyographic activity (EMG) of individual motor units in vastus medialis obliquus (VMO) was recorded via a needle electrode and from Surface electrodes placed over VMO and vastus lateralis (VL). A tape was applied to the skin directly over the patella and stretch was applied via the tape in three directions, while subjects maintained a gentle isometric knee extension effort at constant force. Recordings were made from five separate motor units in each direction. Stretch applied to the skin over the patella increased VMO surface EMG and was greatest with lateral stretch. There was no change in VL surface EMG activity. While there was no net increase in motor unit firing rate, it was increased in the majority of motor units during lateral stretch. Application of stretch to the skin over VMO via the tape can increase VMO activity, suggesting that cutaneous stimulation may be one mechanism by which patella taping produces a clinical effect. (c) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.