35 resultados para Multicolor emission

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong photoluminescent emission has been obtained from 3 nm PbS nanocrystals in aqueous colloidal solution, following treatment with CdS precursors. The observed emission can extend across the entire visible spectrum and usually includes a peak near 1.95 eV. We show that much of the visible emission results from absorption by higher-lying excited states above 3.0 eV with subsequent relaxation to and emission from states lying above the observed band-edge of the PbS nanocrystals. The fluorescent lifetimes for this emission are in the nanosecond regime, characteristic of exciton recombination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free-piston-driven expansion tubes are capable of generating flaw conditions over a wide range of enthalpies ranging from orbital up to superorbital velocities. Initial optical measurements aimed at investigating the flow in such a facility are presented. Emission studies were used to identify impurities in the how and to investigate spectral regions that are accessible by optical techniques. At moderate enthalpies, it was found that significant radiation resulted from metallic contaminants. At high enthalpies, the spectrum consisted of a number of atomic lines together with a broadband background component indicative of the presence of electrons. The presence of this radiation may limit the applicability of optical techniques that require spectral regions free from the influence of atomic transitions or background radiation. Emission spectroscopy (through Stark broadened hydrogen lines) and two-wavelength holographic interferometry were used to measure the electron number density behind a bow shock on a blunt body at conditions where significant ionization was observed. They yielded average concentrations of (3 +/- 1) x 10(17) cm(-3) from the emission measurements and (3.8 +/- 0.6) x 10(17) cm(-3) from the interferometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine a stylized version of EPA auctions when agents know the list of values of sellers and buyers. There are inefficient equilibria where no goods are traded and efficient equilibria where all exchange occurs at a uniform price. We also provide examples under incomplete information when the uniform price equilibrium holds and when it does not hold. (C) 1999 Elsevier Science S.A. All rights reserved. JEL classification: D44; Q29.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the advent of multi-fibre spectrographs such as the 'Two-Degree Field' (2dF) instrument at the Angle-Australian Telescope, quasar surveys that are free of any preselection of candidates and any biases this implies have become possible for the first time. The first of these is that which is being undertaken as part of the Fornax Spectroscopic Survey, a survey of the area around the Fornax Cluster of galaxies, and aims to obtain the spectra of all objects in the magnitude range 16.5 < b(j) < 19.7. To date, 3679 objects in the central pi -deg(2) area have been successfully identified from their spectral characteristics. Of these, 71 are found to be quasars, 61 with redshifts 0.3 < z < 2.2 and 10 with redshifts z > 2.2. Using this complete quasar sample, a new determination of quasar number counts is made, enabling an independent check of existing quasars surveys. Cumulative counts per square degree at a magnitude limit of b(j) < 19.5 are found to be 11.5 +/- 2.2 for 0.3 < z < 2.2, 2.22 +/- 0.93 for z > 2.2 and 13.7 +/- 3.1 for z > 0.3. Given the likely detection of extra quasars in the Fornax survey, we make a more detailed examination of existing quasar selection techniques. First, looking at the use of a stellar criterion, four of the 71 quasars are 'non-stellar' on the basis of the automated plate measuring facility (APM) b(j) classification, however inspection shows all are consistent with stellar, but misclassified due to image confusion. Examining the ultraviolet excess and multicolour selection techniques, for the selection criteria investigated, ultraviolet excess would find 69 +/- 6 per cent of our 0.3 < z < 2.2 quasars and only 50(-18)(+14), per cent of our z > 2.2 quasars, while the completeness level for multicolour selection is found to be 90(-4)(+3) per cent for 0.3 < z < 2.2 quasars and 80(-12)(+14) per cent for z > 2.2 quasars. The extra quasars detected by our all-object survey thus have unusually red star-like colours, and this appears to be a result of the continuum shape rather than any emission features. An intrinsic dust extinction model may, at least partly, account for the red colours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We calculate the stationary state of the system of two non-identical two-level atoms driven by a finite-bandwidth two-mode squeezed vacuum. It is well known that two identical two-level atoms driven by a broadband squeezed vacuum may decay to a pure state, called the pure two-atom squeezed state, and that the presence of the antisymmetric state can change its purity. Here, we show that for small interatomic separations the stationary state of two non-identical atoms is not sensitive to the presence of the antisymmetric state and is the pure two-atom squeezed state. This effect is a consequence of the fact that in the system of two non-identical atoms the antisymmetric state is no longer the trapping state. We also calculate the squeezing properties of the emitted field and find that the squeezing spectrum of the output field may exhibit larger squeezing than that in the input squeezed vacuum. Moreover, we show that squeezing in the total field attains the optimum value which can ever be achieved in the field emitted by two atoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose two quantum error-correction schemes which increase the maximum storage time for qubits in a system of cold-trapped ions, using a minimal number of ancillary qubits. Both schemes consider only the errors introduced by the decoherence due to spontaneous emission from the upper levels of the ions. Continuous monitoring of the ion fluorescence is used in conjunction with selective coherent feedback to eliminate these errors immediately following spontaneous emission events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time evolution of the populations of the collective states of a two-atom system in a squeezed vacuum can exhibit quantum beats. We show that the effect appears only when the carrier frequency of the squeezed field is detuned from the atomic resonance. Moreover, we find that the quantum beats are not present for the case in which the two-photon correlation strength is the maximum possible for a field with a classical analog. We also show that the population inversion between the excited collective states, found for the resonant squeezed vacuum, is sensitive to the detuning and the two-photon correlations. For large detunings or a field with a classical analog there is no inversion between the collective states. Observation of the quantum beats or the population inversion would confirm the essentially quantum-mechanical nature of the squeezed vacuum. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare transient evoked otoacoustic emission (TEOAE) screening outcomes (pass/fail) across the seasons (spring, autumn, and winter) between infants and schoolchildren. A total of 526 infants (275 boys, 251 girls) with a mean age of 2.0 months (SD = 0.38 months) and 975 schoolchildren (513 boys, 462 girls) with a mean age of 6.2 years (SD = 0.36 years) were screened using the ILO Otodynamics Quickscreen program. The same TEOAE pass/fail criterion was applied to the two groups. The results indicated a significant difference in pass rates between infants (91.2% of 1052 ears) and schoolchildren (86.0% of 1950 ears). A seasonal effect was found only for schoolchildren, with a significantly lower pass rate in winter than in spring or autumn. There was no difference in pass rates between spring and autumn. Implications for the seasonal effect on TEOAE screening outcomes for infants and schoolchildren are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic microcavity light-emitting diodes typically exhibit a blueshift of the emitting wavelength with increasing viewing angle. We have modeled the shift of the resonance wavelength for several metal mirrors. Eight metals (Al, Ag, Cr, Ti, Au, Ni, Pt, and Cu) have been considered as top or bottom mirrors, depending on their work functions. The model fully takes into account the dependence of the phase change that occurs on reflection on angle and wavelength for both s and p polarization, as well as on dispersion in the organic layers. Different contributions to the emission wavelength shift are discussed. The influence of the thickness of the bottom mirror and of the choice and thickness of the organic materials inside the cavity has been investigated. Based on the results obtained, guidelines for a choice of materials to reduce blueshift; are given. (C) 2002 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of exchange of substances between blood and tissue has been a long-lasting challenge to physiologists, and considerable theoretical and experimental accomplishments were achieved before the development of the positron emission tomography (PET). Today, when modeling data from modern PET scanners, little use is made of earlier microvascular research in the compartmental models, which have become the standard model by which the vast majority of dynamic PET data are analysed. However, modern PET scanners provide data with a sufficient temporal resolution and good counting statistics to allow estimation of parameters in models with more physiological realism. We explore the standard compartmental model and find that incorporation of blood flow leads to paradoxes, such as kinetic rate constants being time-dependent, and tracers being cleared from a capillary faster than they can be supplied by blood flow. The inability of the standard model to incorporate blood flow consequently raises a need for models that include more physiology, and we develop microvascular models which remove the inconsistencies. The microvascular models can be regarded as a revision of the input function. Whereas the standard model uses the organ inlet concentration as the concentration throughout the vascular compartment, we consider models that make use of spatial averaging of the concentrations in the capillary volume, which is what the PET scanner actually registers. The microvascular models are developed for both single- and multi-capillary systems and include effects of non-exchanging vessels. They are suitable for analysing dynamic PET data from any capillary bed using either intravascular or diffusible tracers, in terms of physiological parameters which include regional blood flow. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of the collective antisymmetric state in entanglement creation by spontaneous emission in a system of two non-overlapping two-level atoms has been investigated. Populations of the collective atomic states and the Wootters entanglement measure (concurrence) for two sets of initial atomic conditions are calculated and illustrated graphically. Calculations include the dipole-dipole interaction and a spatial separation between the atoms that the antisymmetric state of the system is included throughout even for small interatomic separations. It is shown that spontaneous emission can lead to a transient entanglement between the atoms even if the atoms were prepared initially in an unentangled state. It is found that the ability of spontaneous emission to create transient entanglement relies on the absence of population in the collective symmetric state of the system. For the initial state of only one atom excited, entanglement builds up rapidly in time and reaches a maximum for parameter values corresponding roughly to zero population in the symmetric state. On the other hand, for the initial condition of both atoms excited, the atoms remain unentangled until the symmetric state is depopulated. A simple physical interpretation of these results is given in terms of the diagonal states of the density matrix of the system. We also study entanglement creation in a system of two non-identical atoms of different transition frequencies. It is found that the entanglement between the atoms can be enhanced compared to that for identical atoms, and can decay with two different time scales resulting from the coherent transfer of the population from the symmetric to the antisymmetric state. In addition, it was found that a decaying initial entanglement between the atoms can display a revival behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semiconductor based scheme has been proposed for generating entangled photon pairs from the radiative decay of an electrically pumped biexciton in a quantum dot. Symmetric dots produce polarization entanglement, but experimentally realized asymmetric dots produce photons entangled in both polarization and frequency. In this work, we investigate the possibility of erasing the “which-path” information contained in the frequencies of the photons produced by asymmetric quantum dots to recover polarization-entangled photons. We consider a biexciton with nondegenerate intermediate excitonic states in a leaky optical cavity with pairs of degenerate cavity modes close to the nondegenerate exciton transition frequencies. An open quantum system approach is used to compute the polarization entanglement of the two-photon state after it escapes from the cavity, measured by the visibility of two-photon interference fringes. We explicitly relate the two-photon visibility to the degree of the Bell-inequality violation, deriving a threshold at which Bell-inequality violations will be observed. Our results show that an ideal cavity will produce maximally polarization-entangled photon pairs, and even a nonideal cavity will produce partially entangled photon pairs capable of violating a Bell-inequality.