123 resultados para Morton Grove

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: This paper reviews studies of physical activity interventions in health care settings to determine effects on physical activity and/or fitness and characteristics of successful interventions. Methods: Studies testing interventions to promote physical activity in health care settings for primary prevention (patients without disease) and secondary prevention (patients with cardiovascular disease [CVD]) were identified by computerized search methods and reference lists of reviews and articles. Inclusion criteria included assignment to intervention and control groups, physical activity or cardiorespiratory fitness outcome measures, and, for the secondary prevention studies, measurement 12 or more months after randomization. The number of studies with statistically significant effects was determined overall as well as for studies testing interventions with various characteristics. Results: Twelve studies of primary prevention were identified, seven of which were randomized. Three of four randomized studies with short-term measurement (4 weeks to 3 months after randomization), and two of five randomized studies with long-term measurement (6 months after randomization) achieved significant effects on physical activity. Twenty-four randomized studies of CVD secondary prevention were identified; 13 achieved significant effects on activity and/or fitness at twelve or more months. Studies with measurement at two time points showed decaying effects over time, particularly if the intervention were discontinued. Successful interventions contained multiple contacts, behavioral approaches, supervised exercise, provision of equipment, and/or continuing intervention. Many studies had methodologic problems such as low follow-up rates. Conclusion: Interventions in health care settings can increase physical activity for both primary and secondary prevention. Long-term effects are more likely with continuing intervention and multiple intervention components such as supervised exercise, provision of equipment, and behavioral approaches. Recommendations for additional research are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent research has begun to provide support for the assumptions that memories are stored as a composite and are accessed in parallel (Tehan & Humphreys, 1998). New predictions derived from these assumptions and from the Chappell and Humphreys (1994) implementation of these assumptions were tested. In three experiments, subjects studied relatively short lists of words. Some of the Lists contained two similar targets (thief and theft) or two dissimilar targets (thief and steal) associated with the same cue (ROBBERY). AS predicted, target similarity affected performance in cued recall but not free association. Contrary to predictions, two spaced presentations of a target did not improve performance in free association. Two additional experiments confirmed and extended this finding. Several alternative explanations for the target similarity effect, which incorporate assumptions about separate representations and sequential search, are rejected. The importance of the finding that, in at least one implicit memory paradigm, repetition does not improve performance is also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Characteristics of patients who committed suicide were examined to provide a picture of the treatment they received before death and to determine whether and how the suicides could have been pre vented by the service system. Methods: The unnatural-deaths register was matched to the psychiatric case register in the state of Victoria in Australia to identify suicides by people with a history of public-sector psychiatric service use who committed suicide between July 1, 1989, and June 30, 1994. Data on patient and treatment characteristics were examined by three experienced clinicians, who made judgments about whether the suicide could have been prevented had the service system responded differently. Quantitative and qualitative data were descriptively analyzed. Results: A total of 629 psychiatric patients who had committed suicide were identified. Seventy-two percent of the patients were male, 62 percent were under 40 years old, and 51 percent were unmarried. They had a range of disorders, with the most common being schizophrenia or schizoaffective disorder (36 percent). Sixty-seven percent had previously attempted suicide. A total of 311 patients (49 percent) received care within four weeks of death. Twenty percent of the suicides were considered preventable. Key factors associated with preventability were poor staff-patient relationships, incomplete assessments, poor assessment and treatment of depression and psychological problems, and poor continuity of care. Conclusions: Opportunities exist for the psychiatric service system to alter practices at several levels and thereby reduce patient suicides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perceived depth was measured for three-types of stereograms with the colour/texture of half-occluded (monocular) regions either similar to or dissimilar to that of binocular regions or background. In a two-panel random dot stereogram the monocular region was filled with texture either similar or different to the far panel or left blank. In unpaired background stereograms the monocular region either matched the background or was different in colour or texture and in phantom stereograms the monocular region matched the partially occluded object or was a different colour or texture. In all three cases depth was considerably impaired when the monocular texture did not match either the background or the more distant surface. The content and context of monocular regions as well as their position are important in determining their role as occlusion cues and thus in three-dimensional layout. We compare coincidence and accidental view accounts of these effects. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perceived slant was measured for horizontal lines aligned on one side and of varying lengths whose length disparity was either a constant linear amount for all lines (consistent with uniocular occlusion) or proportional to line length (consistent with global slant). Although the disparity of any line was ambiguous with respect to these two possibilities, slant of individual lines did not occur in the former case, but a subjective contour in depth was reported along the alignment. For proportional disparity of the set, global slant was seen. Adding a constant length to each line on the invalid eye for occlusion resulted in multiple slants. Smooth uniocular variations in alignment shape elicited subjective contours slanting or curving in depth. Global context can disambiguate the depth status of individual disparate lines. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Howard and Duke (2003) generated stereograms with a grey transparent square offset from a vertical bar in one eye, and a vertical bar with a gap in the other eye. They argued that these displays were 'without conventional disparity' and that the metrical depth experienced was a new form of unpaired stereopsis due to 'transparency rather than occlusion'. Another possibility is that the perceived depth in these displays was obtained from horizontal contours. To test this possibility, we generated three displays that contained similar horizontal contourterminations, but were inconsistent with transparency. Reliable depth was seen in all stimuli. We conclude that in our stimuli, and those of Howard and Duke, transparency is not responsible for the perception of depth, which appears to be based instead on disparate horizontal contour terminations. Our results also show that disparate contours of opposite contrast polarity can generate depth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A partially occluded contour and a slanted contour may generate identical binocular horizontal disparities. We investigated conditions promoting an occlusion resolution indicated by an illusory contour in depth along the aligned ends of horizontally disparate line sets. For a set of identical oblique lines with a constant width added to one eye's view, strength, depth, and stability of the illusory contour were poor, whereas for oblique lines of alternating orientations the illusory contours were strong, indicating a reliance on vertical size disparities rather than vertical positional disparities in generating perceived occlusion. For horizontal lines, occlusion was seen when the lines were of different lengths and absolute width disparity was invariant across the set. In all line configurations, when the additional length was on the wrong eye to be attributed to differential occlusion, lines appeared slanted consistent with their individual horizontal disparities. This rules out monocular illusory contours as the determining factor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Constructing a veridical spatial map by touch poses at least two problems for a perceptual system. First, as the hand is moved through space, the locations of features may be displaced if there is an uncorrected lag between the moment the hand encounters a feature and the time that feature is encoded on a spatial map. Second, due to the sequential nature of the process, some form of memory, which itself may be subject to spatial distortions, is required for integration of spatial samples. We investigated these issues using a task involving active haptic exploration with a stylus swept back and forth in the horizontal plane at the wrist. Remembered locations of tactile targets were shifted towards the medial axis of the forearm, suggesting a central tendency in haptic spatial memory, while evidence for a displacement of perceived locations in the direction of sweep motion was consistent with processing delays.