17 resultados para Monitoring methods

em University of Queensland eSpace - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A retrospective review was undertaken in 744 patients who were dose-individualized with gentamicin once daily to evaluate a change in gentamicin clearance as a potential predictor of nephrotoxicity. The definition of nephrotoxicity was chosen to be a change in creatinine clearance greater than 20%. Similarly, a change in gentamicin clearance of greater than 20% was also considered a possible index of nephrotoxicity. Four criteria were developed to assess the usefulness of gentamicin clearance as a predictor of nephrotoxicity. Following the application of the inclusion/exclusion criteria, 132 patients were available for the analysis. The sensitivity, specificity, positive predictive value, and negative predictive value were assessed for each of the criteria. Receiver operating characteristic (ROC) curves were produced to determine if an optimum value in the change of gentamicin clearance could be found to maximize sensitivity and specificity. The overall incidence of nephrotoxicity based on a decrease in creatinine clearance by 20% or more was 3.8%. Women were overrepresented in the nephrotoxic group [71.4% versus 40.1% (P = 0.0025)]. Patients with nephrotoxicity had statistically longer treatment periods, increased cumulative dose, and more dosing predictions (P < 0.05 in each case). The sensitivity of the criteria ranged from 43 to 46%, and specificity ranged from 93 to 99%. The positive and negative predictive values ranged from 63 to 94% and 86 to 89%, respectively. In those patients in whom nephrotoxicity was predicted from a change in gentamicin clearance, this change occurred on average 3 days before the change in creatinine clearance (P < 0.05). A change in gentamicin clearance to predict nephrotoxicity may be a useful addition to current monitoring methods, although it is not the complete answer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The usefulness of umbilical artery Doppler velocimetry for the monitoring of diabetic pregnancies is controversial. The aim of the present study was to assess whether umbilical artery Doppler velocity waveform analysis can predict adverse perinatal outcomes for pregnancies complicated by pre-existing diabetes mellitus. Methods: All diabetic pregnancies (type 1 and 2) delivered at Mater Mothers' Hospital, Queensland, between 1 January 1995 and 31 December 1999 were included. All pregnant diabetic women were monitored with umbilical artery Doppler velocimetry at 28, 32, 36, and 38 weeks' gestation. Adverse perinatal outcome was defined as pregnancies with one or more of the following: small-for-gestational age, Caesarean section for non-reassuring cardiotocography, fetal acidaemia at delivery, 1-min Apgar of 3 or less, 5-min Apgar of less than 7, hypoxic ischaemic encephalopathy or perinatal death. Abnormal umbilical artery Doppler velocimetry was defined as a pulsatility index of 95th centile or higher for gestation. Results: One hundred and four pregnancies in women with pre-existing diabetes had umbilical arterial Doppler studies carried out during the study period. Twenty-three pregnancies (22.1%) had an elevated pulsatility index. If the scans were carried out within 2 weeks of delivery, 71% of pregnancies with abnormal umbilical Doppler had adverse outcomes (P < 0.01; likelihood ratio, 4.2). However, the sensitivity was 35%; specificity was 94%; positive predictive value was 80%; and negative predictive value was 68%. Only 30% of women with adverse perinatal outcomes had abnormal umbilical arterial Doppler flow. Conclusion: Umbilical artery Doppler velocimetry is not a good predictor of adverse perinatal outcomes in diabetic pregnancies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dendritic cells (DC) from distinct DC subsets are essential contributors to normal human immune responses. Despite this, reliable assays that enable DC to be counted precisely have been slow to evolve. We have now developed a new single-platform flow cytometric assay based on TruCOUN(TM) beads and the whole blood Lyse/No-Wash protocol that allows precise counting of the CD14(-) blood DC subsets: CD11c(+)CD16(-) DC, CD11c(+)CD16(+) DC, CD123(hi) DC, CD1c(+) DC and BDCA-3(+) DC. This assay requires 50 mul of whole blood; does not rely on a hematology blood analyser for the absolute DC counts; allows DC counting in EDTA samples 24 It after collection; and is suitable for cord blood and peripheral blood. The data is highly reproducible with intra-assay and inter-assay coefficients of variation less than 3% and 11%, respectively. This assay does not produce the DC-T lymphocyte conjugates that result in DC counting abnormalities in conventional gradient-density separation procedures. Using the TruCOUNT assay, we established that absolute blood DC counts reduce with age in healthy individuals. In preliminary studies, we found a significantly lower absolute blood CD11c(+)CD16(+) DC count in stage III/IV versus stage I/II breast carcinoma patients and a lower absolute blood CD123(hi) DC count in multiple myeloma patients, compared to age-matched controls. These data indicate that scientific progress in DC counting technology will lead to the global standardization of DC counting and allow clinically meaningful data to be obtained. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present paper, we have provided an initial assessment of the current and future threats to biodiversity posed by introduced mammals (predators and herbivores) inhabiting the Australian rangelands, exploring trends in populations and options for management. Notably, rabbits have declined in recent years in the wake of rabbit haemorrhagic disease, populations of feral camels have increased dramatically and foxes appear to have moved northwards, thereby threatening native fauna within an expanded range. Following on, we developed a framework for monitoring the impacts of introduced mammals in the Australian rangelands. In doing so, we considered the key issues that needed to be considered in designing a monitoring programme for this purpose and critically evaluated the role of monitoring in pest animal management. Finally we have provided a brief inventory of current best-practice methods of estimating the abundance of introduced mammal populations in the Australian rangelands with some comments on new approaches and their potential applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In wildlife management, the program of monitoring will depend on the management objective. If the objective is damage mitigation, then ideally it is damage that should be monitored. Alternatively, population size (N) can be used as a surrogate for damage, but the relationship between N and damage obviously needs to be known. If the management objective is a sustainable harvest, then the system of monitoring will depend on the harvesting strategy. In general, the harvest strategy in all states has been to offer a quota that is a constant proportion of population size. This strategy has a number of advantages over alternative strategies, including a low risk of over- or underharvest in a stochastic environment, simplicity, robustness to bias in population estimates and allowing harvest policy to be proactive rather than reactive. However, the strategy requires an estimate of absolute population size that needs to be made regularly for a fluctuating population. Trends in population size and in various harvest statistics, while of interest, are secondary. This explains the large research effort in further developing accurate estimation methods for kangaroo populations. Direct monitoring on a large scale is costly. Aerial surveys are conducted annually at best, and precision of population estimates declines with the area over which estimates are made. Management at a fine scale (temporal or spatial) therefore requires other monitoring tools. Indirect monitoring through harvest statistics and habitat models, that include rainfall or a greenness index from satellite imagery, may prove useful.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two water quality monitoring strategies designed to sample hydrophobic organic contaminants have been applied and evaluated across an expected concentration gradient in PAHs in the Moreton region. Semipermeable membrane devices (SPMDs) that sequester contaminants via passive diffusion across a membrane were used to evaluate the concentration of PAHs at four and five sites in spring and summer 2001/2002, respectively. In addition, induction of hepatic cytochrome P4501, EROD activity, in yellowfin bream, Acanthopagrus australis, captured in the vicinity of SPMD sampling sites following deployment in summer was used as a biomarker of exposure to PAHs and related chemicals. SPMDs identified a clear and reproducible gradient in PAH contamination with levels increasing from east to west in Moreton Bay and upstream in the Brisbane River. The highest PAH concentrations expressed as B(a)P-toxicity equivalents (TEQs) were found in urban areas, which were also furthest upstream and experienced the least flushing. Cytochrome P4501 induction in A. australis was similar at all sites. The absence of clear trends in EROD activity may be attributable to factors not measured in this study or variable residency time of A. australis in contaminated areas. It is also possible that fish in the Moreton region are displaying enzymatic adaptation, which has been reported previously for fish subjected to chronic exposure to organic contaminants. These potential interferences complicate interpretation of EROD activity from feral biota. It is, therefore, suggested that future monitoring combine the two methods by applying passive sampler extracts to in vitro EROD assays. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biological wastewater treatment is a complex, multivariate process, in which a number of physical and biological processes occur simultaneously. In this study, principal component analysis (PCA) and parallel factor analysis (PARAFAC) were used to profile and characterise Lagoon 115E, a multistage biological lagoon treatment system at Melbourne Water's Western Treatment Plant (WTP) in Melbourne, Australia. In this study, the objective was to increase our understanding of the multivariate processes taking place in the lagoon. The data used in the study span a 7-year period during which samples were collected as often as weekly from the ponds of Lagoon 115E and subjected to analysis. The resulting database, involving 19 chemical and physical variables, was studied using the multivariate data analysis methods PCA and PARAFAC. With these methods, alterations in the state of the wastewater due to intrinsic and extrinsic factors could be discerned. The methods were effective in illustrating and visually representing the complex purification stages and cyclic changes occurring along the lagoon system. The two methods proved complementary, with each having its own beneficial features. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demonstrating the existence of trends in monitoring data is of increasing practical importance to conservation managers wishing to preserve threatened species or reduce the impact of pest species. However, the ability to do so can be compromised if the species in question has low detectability and the true occupancy level or abundance of the species is thus obscured. Zero-inflated models that explicitly model detectability improve the ability to make sound ecological inference in such situations. In this paper we apply an occupancy model including detectability to data from the initial stages of a fox-monitoring program on the Eyre Peninsula, South Australia. We find that detectability is extremely low (< 18%) and varies according to season and the presence or absence of roadside vegetation. We show that simple methods of using monitoring data to inform management, such as plotting the raw data or performing logistic regression, fail to accurately diagnose either the status of the fox population or its trajectory over time. We use the results of the detectability model to consider how future monitoring could be redesigned to achieve efficiency gains. A wide range of monitoring programs could benefit from similar analyses, as part of an active adaptive approach to improving monitoring and management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Registration of births, recording deaths by age, sex and cause, and calculating mortality levels and differentials are fundamental to evidence-based health policy, monitoring and evaluation. Yet few of the countries with the greatest need for these data have functioning systems to produce them despite legislation providing for the establishment and maintenance of vital registration. Sample vital registration (SVR), when applied in conjunction with validated verbal autopsy, procedures and implemented in a nationally representative sample of population clusters represents an affordable, cost-effective, and sustainable short- and medium-term solution to this problem. SVR complements other information sources by producing age-, sex-, and cause-specific mortality data that are more complete and continuous than those currently available. The tools and methods employed in an SVR system, however, are imperfect and require rigorous validation and continuous quality assurance; sampling strategies for SVR are also still evolving. Nonetheless, interest in establishing SVR is rapidly growing in Africa and Asia. Better systems for reporting and recording data on vital events will be sustainable only if developed hand-in-hand with existing health information strategies at the national and district levels; governance structures; and agendas for social research and development monitoring. If the global community wishes to have mortality measurements 5 or 10 years hence, the foundation stones of SVR must be laid today.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Although both strength training (ST) and endurance training (ET) seem to be beneficial in type 2 diabetes mellitus (T2D), little is known about post-exercise glucose profiles. The objective of the study was to report changes in blood glucose (BG) values after a 4-month ET and ST programme now that a device for continuous glucose monitoring has become available. Materials and methods Fifteen participants, comprising four men age 56.5 +/- 0.9 years and 11 women age 57.4 +/- 0.9 years with T2D, were monitored with the MiniMed (Northridge, CA, USA) continuous glucose monitoring system (CGMS) for 48 h before and after 4 months of ET or ST. The ST consisted of three sets at the beginning, increasing to six sets per week at the end of the training period, including all major muscle groups and ET performed with an intensity of maximal oxygen uptake of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min three times a week. Results A total of 17 549 single BG measurements pretraining (619.7 +/- 39.8) and post-training (550.3 +/- 30.1) were recorded, correlating to an average of 585 +/- 25.3 potential measurements per participant at the beginning and at the end of the study. The change in BG-value between the beginning (132 mg dL(-1)) and the end (118 mg dL(-1)) for all participants was significant (P = 0.028). The improvement in BG-value for the ST programme was significant (P = 0.02) but for the ET no significant change was measured (P = 0.48). Glycaemic control improved in the ST group and the mean BG was reduced by 15.6% (Cl 3-25%). Conclusion In conclusion, the CGMS may be a useful tool in monitoring improvements in glycaemic control after different exercise programmes. Additionally, the CGMS may help to identify asymptomatic hypoglycaemia or hyperglycaemia after training programmes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-year programme to eradicate Feral Cats Felis catus from the island of Baltra in the Galapagos archipelago achieved good results by Initially poisoning with sodium monofluoroacetate (compound 1080) then trapping or shooting the remaining cats. The poisoning campaign removed 90% of the cats, its success being attributable to pre-baiting with unpolsoned baits to accustom cats to eating baits and placing enough baits to ensure that all cats encountered several baits within their home range. This, together with the use of metaclopromide (Pileran) as an anti-emetic, overcame a problem associated with poor retention of 1080 in thawed fish baits that limited the dose available to 1 mg 1080lbait, a quality Insufficient to kill large cats. Removal of the remaining cats was delayed by a weather-Induced irruption of Black Rats Rattus rattus and House Mice Mus musculus that enabled recruitment of kittens in 2002, but made cats more susceptible to trapping and shooting in 2003 when rodent populations collapsed. Since July 2003 no sign of a cat has been detected on Baltra despite extensive searching and monitoring throughout 2004. As cat abundance has decreased there have been more locally-bred Juvenile iguanas (Conolophus subcristatus) seen during annual censuses. However, such recruitment may reflect the increasing maturity and higher fecundity of iguanas repatriated from 1991 onwards rather than being a direct result of reduced cat predation alone. More time is necessary to determine the benefits of reduced cat predation on the Iguana population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fouling is the deposition of milk solids on heat transfer sur aces, particularly heat exchangers. It is a major industrial problem, which causes a decrease in heat transfer efficiency and shortens run times. The resultant effect is a decrease in process efficiency and economy. For studying and monitoring deposit formation, suitable fouling detectors or methods of measuring the deposit are required. This can be achieved through direct means, whereby the deposit is analyzed after a certain time, or indirectly through instrumentation for monitoring parameters such as temperature, pressure, flow rate, overall heat transfer coefficient, heat flux, and other physical properties. This article reviews the various reported fouling detection methods.