19 resultados para Monitoring Systems
em University of Queensland eSpace - Australia
Resumo:
This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.
Resumo:
Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Resumo:
We discuss the phenomenon of system tailoring in the context of data from an observational study of anaesthesia. We found that anaesthetists tailor their monitoring equipment so that the auditory alarms are more informative. However, the occurrence of tailoring by anaesthetists in the operating theatre was infrequent, even though the flexibility to tailor exists on many of the patient monitoring systems used in the study. We present an influence diagram to explain how alarm tailoring can increase situation awareness in the operating theatre but why factors inhibiting tailoring prevent widespread use. Extending the influence diagram, we discuss ways that more informative displays could achieve the results sought by anaesthetists when they tailor their alarm systems. In particular, we argue that we should improve our designs rather than simply provide more flexible tailoring systems. because users often find tailoring a complex task. We conclude that properly designed auditory displays may benefit anaesthetists in achieving greater patient situation awareness and that designers should consider carefully how factors promoting and inhibiting tailoring will affect the end-users' likelihood of conducting tailoring. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Australian heroin markets have recently undergone dramatic change, sparking debate about the nature of such markets. This study aimed to determine the onset, peak and decline of the heroin shortage in New South Wales (NSW), using the most appropriate available methods to detect market level changes. The parameters of the heroin shortage were determined by reviewing: reports of heroin users about availability and price (derived from the existing literature and the Illicit Drug Reporting System); qualitative interviews with injecting drug users, and health and law enforcement professionals working in the illicit drug field; and examining data on heroin seizures over the past decade. There was a marked reduction in heroin supply in NSW in early 2001. An increase in the price of heroin occurred in 2001, whereas it had decreased steadily since 1996. A reduction in purity also occurred, as reported by drug users and heroin seizures. The peak period of the shortage appears to have been January to April 2001. The market appears to have stabilised since that time, although it has not returned to pre- 2001 levels: heroin prices have decreased in NSW for street grams, but not to former levels, and the price of `caps' (street deals) remain elevated. Heroin purity in NSW has remained low, with perhaps a 10% increase above the lowest recorded levels. These data support the notion that the heroin market in NSW underwent significant changes, which appear to have involved a lasting shift in the nature of the market.
Resumo:
We propose a model for non-ideal monitoring of the state of a coupled quantum dot qubit by a quantum tunnelling device. The non-ideality is modelled using an equivalent measurement circuit. This allows realistically available measurement results to be related to the state of the quantum system (qubit). We present a quantum trajectory that describes the stochastic evolution of the qubit state conditioned by tunnelling events (i.e. current) through the device. We calculate and compare the noise power spectra of the current in an ideal and a non-ideal measurement. The results show that when the two qubit dots are strongly coupled the non-ideal measurement cannot detect the qubit state precisely. The limitation of the ideal model for describing a realistic system maybe estimated from the noise spectra.
Resumo:
Since the mid-1990s, numerous methodologies have been developed to assess the management effectiveness of protected areas, many tailored to particular regions or habitats. Recognizing the need for a generic approach, the World Commission on Protected Areas (WCPA) developed an evaluation framework allowing specific evaluation methodologies to be designed within a consistent overall approach. Twenty-seven assessment methodologies were analyzed in relation to this framework. Two types of data were identified: quantitative data derived from monitoring and qualitative data derived from scoring by managers and stakeholders. The distinction between methodologies based on data types reflects different approaches to assessing management. Few methodologies assess all the WCPA framework elements. More useful information for adaptive management will come from addressing all six elements. The framework can be used to adapt existing methodologies or to design new, more comprehensive methodologies for evaluation, using quantitative monitoring data, qualitative scoring data, or a combination of both.
Resumo:
Although the benefits of many psychosocial support strategies in improving well being in women with breast cancer have been demonstrated, few women receive these programs as part of routine care. This paper provides some recommendations, based on experience in Australia, about how access to evidence-based supportive care strategies might be improved through modification of health systems. It demonstrates the paucity of research about the costs and health service implications of psychosocial support strategies, which is vital to health planning and service delivery change. It outlines the systematic approach taken in Australia to improving psychosocial support nationally by: the development of research reviews; preparation of guidelines about supportive care, implementation of programs to foster the adoption of guidelines through modification of policy, health service delivery and clinician training; and monitoring programs. Coalitions of government, health care professionals and consumers are key to effective lobbying for change. If all women with breast cancer are to receive better supportive care, there is a need for approaches which: refocus the research effort in psycho-oncology; develop more strategic approaches to generating change in health systems and health policy and foster partnerships to advocate for improved resources. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
Biological wastewater treatment is a complex, multivariate process, in which a number of physical and biological processes occur simultaneously. In this study, principal component analysis (PCA) and parallel factor analysis (PARAFAC) were used to profile and characterise Lagoon 115E, a multistage biological lagoon treatment system at Melbourne Water's Western Treatment Plant (WTP) in Melbourne, Australia. In this study, the objective was to increase our understanding of the multivariate processes taking place in the lagoon. The data used in the study span a 7-year period during which samples were collected as often as weekly from the ponds of Lagoon 115E and subjected to analysis. The resulting database, involving 19 chemical and physical variables, was studied using the multivariate data analysis methods PCA and PARAFAC. With these methods, alterations in the state of the wastewater due to intrinsic and extrinsic factors could be discerned. The methods were effective in illustrating and visually representing the complex purification stages and cyclic changes occurring along the lagoon system. The two methods proved complementary, with each having its own beneficial features. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Registration of births, recording deaths by age, sex and cause, and calculating mortality levels and differentials are fundamental to evidence-based health policy, monitoring and evaluation. Yet few of the countries with the greatest need for these data have functioning systems to produce them despite legislation providing for the establishment and maintenance of vital registration. Sample vital registration (SVR), when applied in conjunction with validated verbal autopsy, procedures and implemented in a nationally representative sample of population clusters represents an affordable, cost-effective, and sustainable short- and medium-term solution to this problem. SVR complements other information sources by producing age-, sex-, and cause-specific mortality data that are more complete and continuous than those currently available. The tools and methods employed in an SVR system, however, are imperfect and require rigorous validation and continuous quality assurance; sampling strategies for SVR are also still evolving. Nonetheless, interest in establishing SVR is rapidly growing in Africa and Asia. Better systems for reporting and recording data on vital events will be sustainable only if developed hand-in-hand with existing health information strategies at the national and district levels; governance structures; and agendas for social research and development monitoring. If the global community wishes to have mortality measurements 5 or 10 years hence, the foundation stones of SVR must be laid today.
Resumo:
The Thames Estuary, UK, and the Brisbane River, Australia, are comparable in size and catchment area. Both are representative of the large and growing number of the world's estuaries associated with major cities. Principle differences between the two systems relate to climate and human population pressures. In order to assess the potential phytotoxic impact of herbicide residues in the estuaries, surface waters were analysed with a PAM fluorometry-based bioassay that employs the photosynthetic efficiency (photosystem II quantum yield) of laboratory cultured microalgae, as an endpoint measure of phytotoxicity. In addition, surface waters were chemically analysed for a limited number of herbicides. Diuron atrazine and simazine were detected in both systems at comparable concentrations. In contrast, bioassay results revealed that whilst detected herbicides accounted for the observed phytotoxicity of Brisbane River extracts with great accuracy, they consistently explained only around 50% of the phytotoxicity induced by Thames Estuary extracts. Unaccounted for phytotoxicity in Thames surface waters is indicative of unidentified phytotoxins. The greatest phytotoxic response was measured at Charing Cross, Thames Estuary, and corresponded to a diuron equivalent concentration of 180 ng L-1. The study employs relative potencies (REP) of PSII impacting herbicides and demonstrates that chemical analysis alone is prone to omission of valuable information. Results of the study provide support for the incorporation of bioassays into routine monitoring programs where bioassay data may be used to predict and verify chemical contamination data, alert to unidentified compounds and provide the user with information regarding cumulative toxicity of complex mixtures. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Regular monitoring of wastewater characteristics is undertaken on most wastewater treatment plants. The data acquired during this process are usually filed and forgotten. However, systematic analysis of these data can provide useful insights into plant behaviour. Conventional graphical techniques are inadequate to give a good overall picture of how wastewater characteristics vary, with time and along the lagoon system. An approach based on the use of contour plots was devised that largely overcomes this problem. Superimposition of contour plots for different parameters can be used to gain a qualitative understanding of the nature and strength of relationships between the parameters. This is illustrated in an analysis of monitoring data for lagoon 115 East at the Western Treatment Plant, near Melbourne, Australia. In this illustrative analysis, relationships between ammonia removal rates and parameters such as chlorophyll a level and temperature are explored using a contour plot superimposition approach. It is concluded that this approach can help improve our understanding, not only of lagoon systems, but of other wastewater treatment systems as well.