4 resultados para Mammographic X-ray unit

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crystals of purified heterodimeric sulfite dehydrogenase from Starkeya novella have been grown using vapour diffusion. X-ray diffraction data have been collected from crystals of the native protein at lambda=1.0 Angstrom and close to the iron absorption edge at lambda=1.737 Angstrom. The crystals belong to space group P2(1)2(1)2, with unit-cell parameters a=97.5, b=92.5, c=55.9 Angstrom. Native data have been recorded to 1.8 Angstrom resolution and Fe-edge data to 2.5 Angstrom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The crystal structure of the extracellular domain of growth hormone receptor complexed to its ligand, growth hormone, has been known since 1992. However, no information exists for the unliganded form of the receptor. The human growth hormone receptor's extracellular ligand-binding domain, encompassing amino-acid residues 1 - 238, has been expressed in Escherichia coli, purified by anion ion-exchange chromatography and crystallized in its unliganded state by the hanging-drop vapour-diffusion method in 100 mM HEPES pH 7.0 containing 27.5%(w/v) PEG 5000 monomethyl ether and 200 mM ammonium sulfate as the co-precipitants. The crystals belong to the othorhombic space group C222(1), have unit-cell parameters a = 99.7, b = 112.2, c = 93.2 Angstrom and diffract to 2.5 Angstrom resolution using synchrotron radiation. The crystal structure will shed light on the nature of any conformation changes that occur upon ligand binding and will provide information to develop potential low-molecular-weight agonists/antagonists to treat clinical diseases in which the growth hormone receptor is implicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contrast enhanced magnetic resonance imaging (CE MRI) is the most sensitive tool for screening women who are at high familial risk of breast cancer. Our aim in this study was to assess the cost-effectiveness of X-ray mammography (XRM), CE MRI or both strategies combined. In total, 649 women were enrolled in the MARIBS study and screened with both CE MRI and mammography resulting in 1881 screens and 1-7 individual annual screening events. Women aged 35-49 years at high risk of breast cancer, either because they have a strong family history of breast cancer or are tested carriers of a BRCA1, BRCA2 or TP53 mutation or are at a 50% risk of having inherited such a mutation, were recruited from 22 centres and offered annual MRI and XRM for between 2 and 7 years. Information on the number and type of further investigations was collected and specifically calculated unit costs were used to calculate the incremental cost per cancer detected. The numbers of cancer detected was 13 for mammography, 27 for CE MRI and 33 for mammography and CE MRI combined. In the subgroup of BRCA1 (BRCA2) mutation carriers or of women having a first degree relative with a mutation in BRCA1 (BRCA2) corresponding numbers were 3 (6), 12 (7) and 12 (11), respectively. For all women, the incremental cost per cancer detected with CE MRI and mammography combined was 28 pound 284 compared to mammography. When only BRCA1 or the BRCA2 groups were considered, this cost would be reduced to 11 pound 731 (CE MRI vs mammography) and 15 pound 302 (CE MRI and mammography vs mammography). Results were most sensitive to the unit cost estimate for a CE MRI screening test. Contrast-enhanced MRI might be a cost-effective screening modality for women at high risk, particularly for the BRCA1 and BRCA2 subgroups. Further work is needed to assess the impact of screening on mortality and health-related quality of life.