9 resultados para MULTI PHASE FLOW

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simplicity in design and minimal floor space requirements render the hydrocyclone the preferred classifier in mineral processing plants. Empirical models have been developed for design and process optimisation but due to the complexity of the flow behaviour in the hydrocyclone these do not provide information on the internal separation mechanisms. To study the interaction of design variables, the flow behaviour needs to be considered, especially when modelling the new three-product cyclone. Computational fluid dynamics (CFD) was used to model the three-product cyclone, in particular the influence of the dual vortex finder arrangement on flow behaviour. From experimental work performed on the UG2 platinum ore, significant differences in the classification performance of the three-product cyclone were noticed with variations in the inner vortex finder length. Because of this simulations were performed for a range of inner vortex finder lengths. Simulations were also conducted on a conventional hydrocyclone of the same size to enable a direct comparison of the flow behaviour between the two cyclone designs. Significantly, high velocities were observed for the three-product cyclone with an inner vortex finder extended deep into the conical section of the cyclone. CFD studies revealed that in the three-product cyclone, a cylindrical shaped air-core is observed similar to conventional hydrocyclones. A constant diameter air-core was observed throughout the inner vortex finder length, while no air-core was present in the annulus. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A critical assessment is presented for the existing fluid flow models used for dense medium cyclones (DMCs) and hydrocyclones. As the present discussion indicates, the understanding of dense medium cyclone flow is still far from the complete. However, its similarity to the hydrocyclone provides a basis for improved understanding of fluid flow in DMCs. The complexity of fluid flow in DMCs is basically due to the existence of medium as well as the dominance of turbulent particle size and density effects on separation. Both the theoretical and experimental analysis is done with respect to two-phase motions and solid phase flow in hydrocyclones or DMCs. A detailed discussion is presented on the empirical, semiempirical, and the numerical models based upon both the vorticity-stream function approach and Navier-Stokes equations in their primitive variables and in cylindrical coordinates available in literature. The existing equations describing turbulence and multiphase flows in cyclone are also critically reviewed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Numerical simulations of turbulent driven flow in a dense medium cyclone with magnetite medium have been conducted using Fluent. The predicted air core shape and diameter were found to be close to the experimental results measured by gamma ray tomography. It is possible that the Large eddy simulation (LES) turbulence model with Mixture multi-phase model can be used to predict the air/slurry interface accurately although the LES may need a finer grid. Multi-phase simulations (air/water/medium) are showing appropriate medium segregation effects but are over-predicting the level of segregation compared to that measured by gamma-ray tomography in particular with over prediction of medium concentrations near the wall. Further, investigated the accurate prediction of axial segregation of magnetite using the LES turbulence model together with the multi-phase mixture model and viscosity corrections according to the feed particle loading factor. Addition of lift forces and viscosity correction improved the predictions especially near the wall. Predicted density profiles are very close to gamma ray tomography data showing a clear density drop near the wall. The effect of size distribution of the magnetite has been fully studied. It is interesting to note that the ultra-fine magnetite sizes (i.e. 2 and 7 mu m) are distributed uniformly throughout the cyclone. As the size of magnetite increases, more segregation of magnetite occurs close to the wall. The cut-density (d(50)) of the magnetite segregation is 32 gm, which is expected with superfine magnetite feed size distribution. At higher feed densities the agreement between the [Dungilson, 1999; Wood, J.C., 1990. A performance model for coal-washing dense medium cyclones, Ph.D. Thesis, JKMRC, University of Queensland] correlations and the CFD are reasonably good, but the overflow density is lower than the model predictions. It is believed that the excessive underflow volumetric flow rates are responsible for under prediction of the overflow density. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the activity and tolerability of SAM496A, an inhibitor of S-adenosylmethionine decarboxylase (SAMDC), in patients with metastatic melanoma who had not received prior chemotherapy. Selected patients were offered participation in two sub-studies examining early changes in tumor metabolism with FDG-PET and changes in tumor polyamine content. Patients and methods: Fifteen patients with measurable metastatic melanoma, normal cardiac function, and no known CNS metastases were eligible and received SAM486A by 1-hour IV infusion daily for 5 days every 3 weeks. Response was assessed by SWOG criteria. Results: No patient had a confirmed partial response. Fatigue/lethargy, myalgia and neutropenia were the main toxicities but no febrile neutropenia or grade 4 non-hematological toxicity occurred. Five patients had PET scans pre-treatment and on days 8-12 of cycle 1. No patient had reduction of tumor metabolism. Serial biopsy in one patient showed alterations in polyamines consistent with SAMDC inhibition. Conclusions: Using the present dose and schedule of administration, SAM486A does not have significant therapeutic potential in patients with metastatic melanoma.