5 resultados para Lingual wire

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many marine reptiles and birds possess extrarenal salt glands that facilitate the excretion of excess sodium and chloride ions accumulated as a consequence of living in saline environments. Control of the secretory activity of avian salt glands is under neural control, but little information is available on the control of reptilian salt glands. Innervation of the lingual salt glands of the salt water crocodile, Crocodylus porosus, was examined in salt water-acclimated animals using histological methods. Extensive networks of both cholinergic and adrenergic nerve fibres were identified close to salt-secreting lobules and vasculature. The identification of both catecholamine-containing and cholinergic neurons in the salt gland epithelium and close to major blood vessels in the tissue suggests the action of the neurotransmitters on the salt-secreting epithelium itself and the rich vascular network of the lingual salt glands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to investigate how induced lingual fatigue affected lingual strength, articulatory kinematics, and perceptual speech features in CS, a 51-year-old female with active myasthenia gravis (MG), and three age and gender matched control participants, Lingual fatigue was elicited via a series of endurance tasks using a tongue pressure bulb. Following each endurance task, the participants performed a speech task containing the phonemes /k/, /t/, and /j/ that was recorded with an electromagnetic articulograph, followed by a lingual strength assessment using a tongue pressure bulb. Participants repeated this schedule over five phases and kinematic and strength changes during each phase were compared to baseline measurements. All of CSs significant kinematic changes occurred during the final fatigue phase compared to 27.3% of the control group's kinematic changes occurring during this phase, suggesting the kinematic changes associated with fatigue were not accelerated in CS. The endurance tasks also elicited different kinematic effects for CSs anterior and posterior tongue segments. While CS exhibited mostly similar kinematic and perceptual changes to the control group, some of CS's perceptual transcriptions for /k/ and kinematic changes were not replicated, indicating that some different perceptual and physiological consequences to CS's speech were elicited by the endurance tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.

Relevância:

20.00% 20.00%

Publicador: