6 resultados para Laser-induced temperature jump

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents closed form solutions for fully developed temperature distribution and entropy generation due to forced convection in microelectromechanical systems (MEMS) in the Slip-flow regime, for which the Knudsen number lies within the range 0.001

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A finite-difference time-domain (FDTD) thermal model has been developed to compute the temperature elevation in the Sprague Dawley rat due to electromagnetic energy deposition in high-field magnetic resonance imaging (MRI). The field strengths examined ranged from 11.75-23.5 T (corresponding to H-1 resonances of 0.5-1 GHz) and an N-stub birdcage resonator was used to both transmit radio-frequency energy and receive the MRI signals. With an in-plane resolution of 1.95 mm, the inhomogeneous rat phantom forms a segmented model of 12 different tissue types, each having its electrical and thermal parameters assigned. The steady-state temperature distribution was calculated using a Pennes 'bioheat' approach. The numerical algorithm used to calculate the induced temperature distribution has been successfully validated against analytical solutions in the form of simplified spherical models with electrical and thermal properties of rat muscle. As well as assisting with the design of MRI experiments and apparatus, the numerical procedures developed in this study could help in future research and design of tumour-treating hyperthermia applicators to be used on rats in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To systematically review radiofrequency ablation (RFA) for treating liver tumors. Data Sources: Databases were searched in July 2003. Study Selection: Studies comparing RFA with other therapies for hepatocellular carcinoma (HCC) and colorectal liver metastases (CLM) plus selected case series for CLM. Data Extraction: One researcher used standardized data extraction tables developed before the study, and these were checked by a second researcher. Data Synthesis: For HCC, 1.3 comparative studies were included, 4 of which were randomized, controlled trials. For CLM, 13 studies were included, 2 of which were nonrandomized comparative studies and 11 that were case series. There did not seem to be any distinct differences in the complication rates between RFA and any of the other procedures for treatment of HCC. The local recurrence rate at 2 years showed a statistically significant benefit for RFA over percutaneous ethanol injection for treatment of HCC (6% vs 26%, 1 randomized, controlled trial). Local recurrence was reported to be more common after RFA than after laser-induced thermotherapy, and a higher recurrence rate and a shorter time to recurrence were dassociated with RFA compared with surgical resection (1 nonrandomized study each). For CLM, the postoperative complication rate ranged from 0% to 33% (3 case series). Survival after diagnosis was shorter in the CLM group treated with RFA than in the surgical resection group (1 nonrandomized study). The CLM local recurrence rate after RFA ranged from 4% to 55% (6 case series). Conclusions: Radiofrequency ablation may be more effective than other treatments in terms of less recurrence of HCC and may be as sale, although the evidence is scant. There was not enough evidence to determine the safety or efficacy of RFA for treatment of CLM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Exposure to ethylene gas elicits flower abscission from cut stems of Geraldton waxflower (Chamelaucium uncinatum Schauer). Ethylene response rates in plants are mediated by temperature. At 20degreesC, flower abscission from waxflower 'Purple Pride' occurred upon 12 h exposure to I mu11(-1) ethylene. This ethylene treatment did not cause flower abscission at either 10 or 2degreesC. Moreover, flowers held at 2degreesC were insensitive to 48 h exposure to 1, 10 and 100 mu11(-1) ethylene. However, increasing the duration of treatment with I mu11(-1) ethylene at 10 and 2degreesC to 48 and 144 h, respectively, induced flower abscission. When flowers were held at 20degreesC in air without exogenous ethylene following continuous exposure to I mu11(-1) ethylene at 2degreesC, the duration required to elicit flower abscission was reduced from 144 to 72 It. Collectively, these responses show that maintaining harvested waxflower at low temperature (e.g. 2degreesC) is an effective means to minimise ethylene-mediated flower abscission.