6 resultados para Laboratories - Quality control
em University of Queensland eSpace - Australia
Resumo:
The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study entry is essential to appropriately characterize hypertension in these elderly patients.
Resumo:
Medical microbiology and virology laboratories use nucleic acid tests (NAT) to detect genomic material of infectious organisms in clinical samples. Laboratories choose to perform assembled (or in-house) NAT if commercial assays are not available or if assembled NAT are more economical or accurate. One reason commercial assays are more expensive is because extensive validation is necessary before the kit is marketed, as manufacturers must accept liability for the performance of their assays, assuming their instructions are followed. On the other hand, it is a particular laboratory's responsibility to validate an assembled NAT prior to using it for testing and reporting results on human samples. There are few published guidelines for the validation of assembled NAT. One procedure that laboratories can use to establish a validation process for an assay is detailed in this document. Before validating a method, laboratories must optimise it and then document the protocol. All instruments must be calibrated and maintained throughout the testing process. The validation process involves a series of steps including: (i) testing of dilution series of positive samples to determine the limits of detection of the assay and their linearity over concentrations to be measured in quantitative NAT; (ii) establishing the day-to-day variation of the assay's performance; (iii) evaluating the sensitivity and specificity of the assay as far as practicable, along with the extent of cross-reactivity with other genomic material; and (iv) assuring the quality of assembled assays using quality control procedures that monitor the performance of reagent batches before introducing new lots of reagent for testing.
Resumo:
Background and purpose Survey data quality is a combination of the representativeness of the sample, the accuracy and precision of measurements, data processing and management with several subcomponents in each. The purpose of this paper is to show how, in the final risk factor surveys of the WHO MONICA Project, information on data quality were obtained, quantified, and used in the analysis. Methods and results In the WHO MONICA (Multinational MONItoring of trends and determinants in CArdiovascular disease) Project, the information about the data quality components was documented in retrospective quality assessment reports. On the basis of the documented information and the survey data, the quality of each data component was assessed and summarized using quality scores. The quality scores were used in sensitivity testing of the results both by excluding populations with low quality scores and by weighting the data by its quality scores. Conclusions Detailed documentation of all survey procedures with standardized protocols, training, and quality control are steps towards optimizing data quality. Quantifying data quality is a further step. Methods used in the WHO MONICA Project could be adopted to improve quality in other health surveys.