5 resultados para In vitro permeation

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The skin localization of steroids following topical application is largely unknown. We determined the distribution of five steroids in human skin using excised epidermal, dermal, and full-thickness membranes in vitro. There was no significant difference in steroid maximum flux through epidermal and full-thickness membranes, other than significantly lower fluxes for the most polar steroid, aldosterone. Hydrocortisone had the highest dermal diffusivity and dermal penetration, and the accumulation of hydrocortisone and corticosterone was higher than that of the other steroids. Slower penetration and higher accumulation in the viable epidermis of progesterone in full-thickness skin were consistent with dermal penetration limitation effects associated with high lipophilicity. Copyright (c) 2006 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of three vehicles, phosphate-buffered saline (PBS), ethanol (50% in PBS w/w) and propylene glycol (50% in PBS w/w) on in vitro transdermal penetration of testosterone was investigated in the horse. Skin was harvested from the thorax of five Thoroughbred horses after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into Franz-type diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled [C-14]testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when testosterone was dissolved in a vehicle containing 50% ethanol or 50% propylene glycol, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in clinical response to testosterone could be expected with formulation design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about the transdermal penetration of hydrocortisone in the horse and, although commercial formulations containing hydrocortisone are registered for topical use in the horse, there have been no studies investigating the movement of this glucocorticoid through different regions of equine skin. Skin was harvested from the thorax, groin and leg (dorsal metacarpal) regions of five Thoroughbred geldings and frozen (-20 degrees C) until required. Defrosted skin was placed in Franz-type diffusion cells and the amount of radiolabelled (H-3) hydrocortisone, in a saturated solution of unlabelled hydrocortisone in 50% ethanol (w/w), which penetrated through and remained within skin samples was measured over 24 h. Significantly higher (P < 0.001) maximum flux (J(max); mol/cm(2)/h) was measured when hydrocortisone was applied to skin from the leg, compared to thorax and groin, although significantly less hydrocortisone (P < 0.001) was retained within skin from the leg at 24 h. Topical application of hydrocortisone in a vehicle containing ethanol would penetrate faster through leg skin from the lower leg when compared with the thorax or groin, which depending on cutaneous blood flow, may result in higher systemic drug concentrations or greater efficiency in treating local inflamed tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of the vehicles phosphate-buffered saline (PBS), ethanol (EtOH; 50% in PBS w/w) and propylene glycol (PG; 50% in PBS w/w) and the region of administration on in vitro transdermal penetration of testosterone was investigated in the dog. Skin was harvested from the thorax, neck (dorsal part) and groin regions of greyhounds after euthanasia and stored at -20 degrees C until required. The skin was then de-frosted and placed into Franz-type diffusion cells which were maintained at approximately 32 degrees C by a water-bath. Saturated solutions of testosterone, containing trace amounts of radiolabelled (C-14) testosterone, in each vehicle were applied to the outer (stratum corneum) surface of each skin sample and aliquots of receptor fluid were collected at 0, 2, 4, 8, 16, 20, 22 and 24 h and analysed for testosterone by scintillation counting. The maximum flux (J(max)) of testosterone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH or 50% PG, compared to PBS. In contrast, higher residues of testosterone were found remaining within the skin when PBS was used as a vehicle. This study shows that variability in percutaneous penetration of testosterone could be expected with formulation design and site of application. (C) 2004 Elsevier Ltd. All rights reserved.