10 resultados para Imaging techniques

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Indirect evidence indicates that morphine-3-glucuronide (M3G) may contribute significantly to the neuro-excitatory side effects (myoclonus and allodynia) of large-dose systemic morphine. To gain insight into the mechanism underlying M3G' s excitatory behaviors, We used fluo-3 fluorescence digital imaging techniques to assess the acute effects of M3G (5-500 muM) on the cytosolic calcium concentration ([Ca2+](CYT)) in cultured embryonic hippocampal neurones. Acute (3 min) exposure of neurones to M3G evoked [Ca2+](CYT) transients that were typically either (a) transient oscillatory responses characterized by a rapid increase in [Ca2+](CYT) oscillation amplitude that was sustained for at least similar to30 s or (b) a sustained increase in [Ca2+](CYT) that slowly recovered to baseline. Naloxone-pretreatment decreased the proportion of M3G-responsive neurones by 10%-25%, implicating a predominantly non-opioidergic mechanism. Although the naloxone-insensitive M3G-induced increases in [Ca2+](CYT) were completely blocked by N-methyl-D-aspartic acid (NMDA) antagonists and 6-cyano-7-nitroquinoxaline-2,3-dione (CNQX) (alphaamino-3-hydroxy-5-methyl-4-isoxazolepropiordc acid/ kainate antagonist), CNQX did not block the large increase in [Ca2+](CYT) evoked by NMDA (as expected), confirming that N13G indirectly activates the NMDA receptor. Additionally, tetrodotoxin (Na+ channel blocker), baclofen (gamma-aminobutyric acid, agonist), MVIIC (P/Q-type calcium channel blocker), and nifedipine (L-type calcium channel blocker) all abolished M3G-induced increases in [Ca2+](CYT), suggesting that M3G may produce its neuro-excitatory effects by modulating neurotransmitter release. However, additional characterization is required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Resistance training has been shown to be the most effective exercise mode to induce anabolic adaptations in older men and women. Advances in imaging techniques and histochemistry have increased the ability to detect such changes, confirming the high level of adaptability that remains in aging skeletal muscle. This brief review presents a summary of the resistance-training studies that directly compare chronic anabolic responses to training in older (> 60 years) men and women. Sixteen studies are summarized, most of which indicate similar relative anabolic responses between older men and women after resistance training. Relatively small sample sizes in most of the interventions limited their ability to detect significant sex differences and should be considered when interpreting these studies. Future research should incorporate larger sample sizes with multiple measurement time points for anabolic responses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We sought to determine the relative impact of myocardial scar and viability on post-infarct left ventricular (LV) remodeling in medically-treated patients with LV dysfunction. Forty patients with chronic ischemic heart disease (age 64±9, EF 40±11%) underwent rest-redistribution Tl201 SPECT (scar = 50% transmural extent), A global index of scarring for each patient (CMR scar score) was calculated as the sum of transmural extent scores in all segts. LV end diastolic volumes (LVEDV) and LV end systolic volumes (LVESV) were measured by real-time threedimensional echo at baseline and median of 12 months follow-up. There was a significant positive correlation between change in LVEDV with number of scar segts by all three imaging techniques (LVEDV: SPECT scar, r = 0.62, p < 0.001; DbE scar, r = 0.57, p < 0.001; CMR scar, r = 0.52, p < 0.001) but change in LV volumes did not the correlate with number of viable segments. ROC curve analysis showed that remodeling (LVEDV> 15%) was predicted bySPECTscars(AUC= 0.79),DbEscars(AUC= 0.76),CMR scars (AUC= 0.70), and CMR scar score (AUC 0.72). There were no significant differences between any of the ROC curves (Z score

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We sought to determine the relative impact of myocardial scar and viability on post-infarct left ventricular (LV) remodeling in medically-treated patients with LV dysfunction. Forty patients with chronic ischemic heart disease (age 64±9, EF 40±11%) underwent rest-redistribution Tl201 SPECT (scar = 50% transmural extent), A global index of scarring for each patient (CMR scar score) was calculated as the sum of transmural extent scores in all segts. LV end diastolic volumes (LVEDV) and LV end systolic volumes (LVESV) were measured by real-time threedimensional echo at baseline and median of 12 months follow-up. There was a significant positive correlation between change in LVEDV with number of scar segts by all three imaging techniques (LVEDV: SPECT scar, r = 0.62, p < 0.001; DbE scar, r = 0.57, p < 0.001; CMR scar, r = 0.52, p < 0.001) but change in LV volumes did not the correlate with number of viable segments. ROC curve analysis showed that remodeling (LVEDV> 15%) was predicted bySPECTscars(AUC= 0.79),DbEscars(AUC= 0.76),CMR scars (AUC= 0.70), and CMR scar score (AUC 0.72). There were no significant differences between any of the ROC curves (Z score

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Left atrial (LA) volume (LAV) is a prognostically important biomarker for diastolic dysfunction, but its reproducibility on repeated testing is not well defined. LA assessment with 3-dimensional. (3D) echocardiography (3DE) has been validated against magnetic resonance imaging, and we sought to assess whether this was superior to existing measurements for sequential echocardiographic follow-up. Methods: Patients (n = 100; 81 men; age 56 +/- 14 years) presenting for LA evaluation were studied with M-mode (MM) echocardiography, 2-dimensional (2D) echocardiography, and 3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 hour without alteration of hemodynamics or therapy. In all, 20 patients were studied for interobserver and intraobserver variation. LAVs were calculated by using M-mode diameter and planimetered atrial area in the apical. 4-chamber view to calculate an assumed sphere, as were prolate ellipsoid, Simpson's biplane, and biplane area-length methods. All were compared with 3DE. Results: The average LAV was 72 +/- 27 mL by 3DE. There was significant underestimation of LAV by M-mode (35 +/- 20 mL, r = 0.66, P < .01). The 3DE and various 2D echocardiographic techniques were well correlated: LA planimetry (85 +/- 38 mL, r = 0.77, P < .01), prolate ellipsoid (73 +/- 36 mL, r = 0.73, P = .04), area-length (64 +/- 30 mL, r = 0.74, P < .01), and Simpson's biplane (69 +/- 31 mL, r = 0.78, P = .06). Test-retest variation for 3DE was most favorable (r = 0.98, P < .01), with the prolate ellipsoid method showing most variation. Interobserver agreement between measurements was best for 3DE (r = 0.99, P < .01), with M-mode the worst (r = 0.89, P < .01). Intraobserver results were similar to interobserver, the best correlation for 3DE (r = 0.99, P < .01), with LA planimetry the worst (r = 0.91, P < .01). Conclusions. The 2D measurements correlate closely with 3DE. Follow-up assessment in daily practice appears feasible and reliable with both 2D and 3D approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microbial communities play important roles in the functioning of coral reef communities. However, extensive autofluorescence of coral tissues and endosymbionts limits the application of standard fluorescence in situ hybridization (FISH) techniques for the identification of the coral-associated bacterial communities. This study overcomes these limitations by combining FISH and spectral imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two-dimensional (2-D) strain (epsilon(2-D)) on the basis of speckle tracking is a new technique for strain measurement. This study sought to validate epsilon(2-D) and tissue velocity imaging (TVI)based strain (epsilon(TVI)) with tagged harmonic-phase (HARP) magnetic resonance imaging (MRI). Thirty patients (mean age. 62 +/- 11 years) with known or suspected ischemic heart disease were evaluated. Wall motion (wall motion score index 1.55 +/- 0.46) was assessed by an expert observer. Three apical images were obtained for longitudinal strain (16 segments) and 3 short-axis images for radial and circumferential strain (18 segments). Radial epsilon(TVI) was obtained in the posterior wall. HARP MRI was used to measure principal strain, expressed as maximal length change in each direction. Values for epsilon(2-D), epsilon(TVI), and HARP MRI were comparable for all 3 strain directions and were reduced in dysfunctional segments. The mean difference and correlation between longitudinal epsilon(2-D) and HARP MRI (2.1 +/- 5.5%, r = 0.51, p < 0.001) were similar to those between longitudinal epsilon(TVI), and HARP MRI (1.1 +/- 6.7%, r = 0.40, p < 0.001). The mean difference and correlation were more favorable between radial epsilon(2-D) and HARP MRI (0.4 +/- 10.2%, r = 0.60, p < 0.001) than between radial epsilon(TVI), and HARP MRI (3.4 +/- 10.5%, r = 0.47, p < 0.001). For circumferential strain, the mean difference and correlation between epsilon(2-D) and HARP MRI were 0.7 +/- 5.4% and r = 0.51 (p < 0.001), respectively. In conclusion, the modest correlations of echocardiographic and HARP MRI strain reflect the technical challenges of the 2 techniques. Nonetheless, epsilon(2-D) provides a reliable tool to quantify regional function, with radial measurements being more accurate and feasible than with TVI. Unlike epsilon(TVI), epsilon(2-D) provides circumferential measurements. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Myocardial viability (VM) assessment based on wall motion scoring (WMS) with dobutamine echo (DbE) is difficult and subjective. New quantitative techniques such as strain rate imaging (SRI) correspond with isotopic techniques but their ability to predict functional recovery (FR) after revascularization is unclear. Methods. Stable post-MI pts (n=43, age 63±9, EF 36±6%) underwent SRI during DbE. WMS evidence of VM was based on lowdose augmentation at DbE. SR, end-systolic strain (ESS), post-systolic strain (PSS) and timing were analyzed at rest and low dose in abnormal segts. Pts were followed for 9±12 months; FR was defined as segt improvement on post-revascularization images. Results: Of 180 segts with abnormal resting function, 83 showed FR and 97 did not. Resting parameters were not predictive of recovery; resting post-systolic shortening had a sensitivity and specificity

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large areas of tropical sub- and inter-tidal seagrass beds occur in highly turbid environments and cannot be mapped through the water column. The purpose of this project was to determine if and how airborne and satellite imaging systems could be used to map inter-tidal seagrass properties along the wet-tropics coast in north Queensland, Australia. The work aimed to: (1) identify the minimum level of seagrass foliage cover that could be detected from airborne and satellite imagery; and (2) define the minimum detectable differences in seagrass foliage cover in exposed intertidal seagrass beds. High resolution spectral-reflectance data (2040 bands, 350 – 2500nm) were collected over 40cm diameter plots from 240 sites on Magnetic Island, Pallarenda Beach and Green Island in North Queensland at spring low tides in April 2006. The seagrass species sampled were: Thalassia hemprechii, Halophila ovalis, Halodule uninerivs; Syringodium isoetifolium, Cymodocea serrulata, and Cymodoea rotundata. Digital photos were captured for each plot and used to derive estimates of seagrass species cover, epiphytic growth, micro- and macro-algal cover, and substrate colour. Sediment samples were also collected and analysed to measure the concentration of Chlorophyll-a associated with benthic micro-algae. The field reflectance spectra were analysed in combination with their corresponding seagrass species foliage cover levels to establish the minimum foliage projective cover required for each seagrass to be significantly different from bare substrate and substrate with algal cover. This analysis was repeated with reflectance spectra resampled to the bandpass functions of Quickbird, Ikonos, SPOT 5 and Landsat 7 ETM. Preliminary results indicate that conservative minimum detectable seagrass cover levels across most the species sampled were between 30%- 35% on dark substrates. Further analysis of these results will be conducted to determine their separability and satellite images and to assess the effects epiphytes and algal cover.