15 resultados para ISM: bubbles

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new, accurate measurement of the H I mass function of galaxies from the HIPASS Bright Galaxy Catalog, a sample of 1000 galaxies with the highest H I peak flux densities in the southern (delta

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Froth recovery measurements have been conducted in both the presence (three-phase froth) and absence (two-phase froth) of particles of different contact angles in a specially modified laboratory flotation column. Increasing the particle hydrophobicity increased the flow rate of particles entering the froth, while the recovery of particles across the froth phase itself also increased for particle contact angles to 63 and at all vertical heights of the froth column. However, a further increase in the contact angle to 69 resulted in lower particle recovery across the froth phase. The reduced froth recovery for particles of 69 contact angle was linked to significant bubble coalescence within the froth phase. The reduced froth recovery occurred uniformly across the entire particle size range, and was, presumably, a result of particle detachment from coalescing bubbles. Water flow rates across the froth phase also varied with particle contact angle. The general trend was a decrease in the concentrate flow rate of water with increasing particle contact angle. An inverse relationship between water flow rate and bubble radius was also observed, possibly allowing prediction of water flow rate from bubble size measurements in the froth. Comparison of the froth structure, defined by bubble size, gas hold-up and bubble layer thickness, for two- and three-phase froths, at the same frother concentration, showed there was a relationship between water flow rate and froth structure. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The problem of asset price bubbles, and more generally of instability in the financial system, has been a matter of concern since the 1980s but has only recently moved to the center of the macroeconomic policy debate. The main concern with bubbles arises when they burst, imposing losses on investors holding the bubble assets and potentially on the financial institutions that have extended credit to them. Asset price volatility is an inevitable consequence of financial market liberalization and, in extreme cases, generates asset price bubbles, the bursting of which can impose substantial economic and social costs. Policy responses within the existing liberalized financial system face daunting levels of uncertainty and risk. Given the pattern of increasing asset market volatility over recent decades and the policy issues highlighted in this paper, the future looks uncertain. Another significant cycle of asset price movements, especially in one of the major economies, could see a fundamental revision of thinking about the costs and benefits of liberalized financial systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we use computational fluid dynamics (CFD) to study the effect of contact angle on droplet shape as it moves through a contraction. A new non-dimensional number is proposed in order to predict situations where the deformed droplet will form a slug in the contraction and thus have the opportunity to interact with the channel wall. It is proposed that droplet flow into a contraction is a useful method to ensure that a droplet will wet a channel surface without a trapped lubrication film, and thus help ensure that a slug will remain attached to the wall downstream of the contraction. We demonstrate that when a droplet is larger than a contraction, capillary and Reynolds numbers, and fluid properties may not be sufficient to fully describe the droplet dynamics through a contraction. We show that, with everything else constant, droplet shape and breakup can be controlled simply by changing the wetting properties of the channel wall. CFD simulations with contact angles ranging from 30 degrees to 150 degrees show that lower contact angles can induce droplet breakup while higher contact angles can form slugs with contact angle dependent shape. Crown Copyright (c) 2005 Published by Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water recovery is one of the key parameters in flotation modelling for the purposes of plant design and process control, as it determines the circulating flow and residence time in the individual process units in the plant and has a significant effect on entrainment and froth recovery. This paper reviews some of the water recovery models available in the literature, including both empirical and fundamental models. The selected models are tested using the data obtained from the experimental work conducted in an Outokumpu 3 m(3) tank cell at the Xstrata Mt Isa copper concentrator. It is found that all the models fit the experimental data reasonably well for a given flotation system. However, the empirical models are either unable to distinguish the effect of different cell operating conditions or required to determine the empirical model parameters to be derived in an existing flotation system. The model developed by [Neethling, SJ., Lee, H.T., Cilliers, J.J., 2003, Simple relationships for predicting the recovery of liquid from flowing foams and froths. Minerals Engineering 16, 1123-1130] is based on fundamental understanding of the froth structure and transfer of the water in the froth. It describes the water recovery as a function of the cell operating conditions and the froth properties which can all be determined on-line. Hence, the fundamental model can be used for process control purposes in practice. By incorporating additional models to relate the air recovery and surface bubble size directly to the cell operating conditions, the fundamental model can also be used for prediction purposes. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For nearly 100 years, the flotation plant metallurgist has often wondered what is happening 'beneath the froth'. To assist in unravelling this mystery, new technology has been developed as part of the Australian Mineral Industries Research Association (AMIRA) P9 project, to measure gas dispersion characteristics (such as gas hold-up, superficial gas velocity and bubble size) in industrial flotation cells. These measurements have been conducted in a large number of cells of different types and sizes by researchers from the Julius Kruttschnitt Mineral Research Centre (JKMRC) and JKTech. A large database has been developed and the contents of this database are described in this paper. Typical cell characterization measurements show a wide spread in values, even in the same cell types and sizes performing similar duties. In conventional flotation cells, the typical gas hold-up values range from 3% to 20%, bubble sizes range between I and 2 mm, and superficial gas velocity ranges from 1 to 2.5 cm/s. The ranges of cell characterization measurements given in this paper will enable plant personnel to compare their operation to other similar types of operations from around Australia and the rest of the world, giving opportunities for further improvement to flotation plant operations. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We introduce the Survey for Ionization in Neutral Gas Galaxies (SINGG), a census of star formation in H I selected galaxies. The survey consists of H alpha and R-band imaging of a sample of 468 galaxies selected from the H I Parkes All Sky Survey (HIPASS). The sample spans three decades in H I mass and is free of many of the biases that affect other star-forming galaxy samples. We present the criteria for sample selection, list the entire sample, discuss our observational techniques, and describe the data reduction and calibration methods. This paper focuses on 93 SINGG targets whose observations have been fully reduced and analyzed to date. The majority of these show a single emission line galaxy (ELG). We see multiple ELGs in 13 fields, with up to four ELGs in a single field. All of the targets in this sample are detected in H alpha, indicating that dormant (non-star-forming) galaxies with M-H I greater than or similar to 3x10(7) M-circle dot are very rare. A database of the measured global properties of the ELGs is presented. The ELG sample spans 4 orders of magnitude in luminosity (H alpha and R band), and H alpha surface brightness, nearly 3 orders of magnitude in R surface brightness and nearly 2 orders of magnitude in H alpha equivalent width (EW). The surface brightness distribution of our sample is broader than that of the Sloan Digital Sky Survey (SDSS) spectroscopic sample, the EW distribution is broader than prism-selected samples, and the morphologies found include all common types of star-forming galaxies (e.g., irregular, spiral, blue compact dwarf, starbursts, merging and colliding systems, and even residual star formation in S0 and Sa spirals). Thus, SINGG presents a superior census of star formation in the local universe suitable for further studies ranging from the analysis of H II regions to determination of the local cosmic star formation rate density.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Jameson Cell is a high intensity flotation device, which utilises induced air from the atmosphere. It was developed jointly by Mount Isa Mines and Professor Graeme Jameson of the University of Newcastle in the 1980s. It is proven to generate fine bubbles, in the order of 300 to 500 µm, in a high intensity, high shear and compact zone contained in the downcomer. This aerated mixture exits the downcomer into the pulp zone, which is the quiescent mineral and gangue separation zone. A number of Australian base metal flotation circuits feature a reverse flotation stage at the head of the circuit. Testwork and plant operating data has shown that the use of a Jameson Cell in the prefloat cleaner application has further improved prefloat gangue recovery and selectivity. Operation of a Jameson Cell in a carbonaceous/pyrite prefloat cleaner duty at the Mt Isa copper concentrator increased copper recovery and reduced pyrite in the copper concentrate. Testwork at Zinifex Century Zinc Mine showed a decrease in zinc losses by the utilisation of Jameson Cell prefloat cleaner. Appraisal of a Jameson Cell in a scalping role within the Mt Isa Copper Concentrator indicated significant benefits could be achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents investigations into an indoor 2×2 multiple input multiple output (MIMO) system, whose diversity performance is assessed using a high precision test-bed. In this system, transmitter and receiver are equipped with 180° or 90° 3dB hybrids with their two output ports terminated with co-polar monopole antennas. By feeding a signal to one of the two input ports of the hybrid (while the other input port is matched terminated) different communication channels in a rich-scattering environment can be created. The test-bed allows for the signal strength measurements around the receiver/ transmitter sides for a given feeding configuration of hybrids when the receiver is moved over a circular region in an indoor environment. The signal strengths maps obtained for various modes of this 2×2 MIMO system are foundations for investigating transmit/receive diversity schemes. As the signal strength measurement results are obtained with Bluetooth modules operating in the ISM 2.4 GHz, the results are of importance to many other wireless systems that aim at utilizing MIMO diversity schemes to enhance their performance in this frequency band.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a high precision testbed for evaluating antenna diversity techniques in an indoor environment. Details concerning mechanical, electrical and electronics hardware and associated measurement software are described. Initial measurement results for two Bluetooth modules operating with co-polar and cross-polar monopole antennas in the ISM 2.4 GHz band are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Promoted ignition tests and quench tests have been conducted and analysed for 3.2 mm aluminum rods in 99.995% oxygen. Tests have been conducted in oxygen pressures varying from 538 kPa to 773 kPa. Samples that self-extinguished or were quenched were selected for further analysis. The microstructure of the selected samples were analysed by electron microscopy, using energy dispersive spectrometry and electron back-scatter techniques, to identify and visualize, respectively, the species present. The grain structures of these samples were etched, viewed and photographed under polarized light by an optical microscope. From the micrographs produced by the post-test analysis, clearly defined boundaries between the oxide and the melted and resolidified metal have been observed. In both the melted and resolidified metal and the oxide layer, significant numbers of gas bubbles, solid inclusions and several diffuse oxide bubbles have been captured during the cooling process. It is concluded that convective movement is occurring within the molten drop and that analysis of quenched samples provides more useful information on the state of the burning droplet than samples allowed to cool slowly to room temperature. Recommendations are made regarding future investigations into aluminum burning, focusing on the transport of reactants through the liquid oxide layer.