8 resultados para INTRAPARTUM CARDIOTOCOGRAPHY

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal wellbeing during labour, compared with no testing or alternative additional testing (pH, fetal pulse oximetry, etc) for women exhibiting a non-reassuring cardiotocograph trace. A secondary objective of the review is to determine whether effectiveness and risks of intrapartum fetal scalp lactate sampling is influenced by the following: stage of labour; gestation less than 37 completed weeks, greater than or equal to 37 completed weeks; additional tests performed to confirm the presence or absence of fetal acidemia during labour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The usefulness of umbilical artery Doppler velocimetry for the monitoring of diabetic pregnancies is controversial. The aim of the present study was to assess whether umbilical artery Doppler velocity waveform analysis can predict adverse perinatal outcomes for pregnancies complicated by pre-existing diabetes mellitus. Methods: All diabetic pregnancies (type 1 and 2) delivered at Mater Mothers' Hospital, Queensland, between 1 January 1995 and 31 December 1999 were included. All pregnant diabetic women were monitored with umbilical artery Doppler velocimetry at 28, 32, 36, and 38 weeks' gestation. Adverse perinatal outcome was defined as pregnancies with one or more of the following: small-for-gestational age, Caesarean section for non-reassuring cardiotocography, fetal acidaemia at delivery, 1-min Apgar of 3 or less, 5-min Apgar of less than 7, hypoxic ischaemic encephalopathy or perinatal death. Abnormal umbilical artery Doppler velocimetry was defined as a pulsatility index of 95th centile or higher for gestation. Results: One hundred and four pregnancies in women with pre-existing diabetes had umbilical arterial Doppler studies carried out during the study period. Twenty-three pregnancies (22.1%) had an elevated pulsatility index. If the scans were carried out within 2 weeks of delivery, 71% of pregnancies with abnormal umbilical Doppler had adverse outcomes (P < 0.01; likelihood ratio, 4.2). However, the sensitivity was 35%; specificity was 94%; positive predictive value was 80%; and negative predictive value was 68%. Only 30% of women with adverse perinatal outcomes had abnormal umbilical arterial Doppler flow. Conclusion: Umbilical artery Doppler velocimetry is not a good predictor of adverse perinatal outcomes in diabetic pregnancies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Fetal scalp lactate testing has been shown to be as useful as pH with added benefits. One remaining question is What level of lactate should trigger intervention in the first stage of labour?' Aims: This study aimed to establish the lactate level in the first stage of labour that indicates the need for intervention to ensure satisfactory outcomes for both babies and mothers. Methods: A prospective study at Mater Mothers' Hospital, Brisbane, Australia, a tertiary referral centre. One hundred and forty women in labour, with non-reassuring fetal heart rate traces, were tested using fetal blood scalp sampling of 5 mu L of capillary blood tested on an Accusport (Boeringer, Mannheim, East Sussex, UK) lactate meter. Decision to intervene in labour was based on clinical assessment plus a predetermined cut off. Main outcome measures were APGAR scores, cord arterial pH, meconium stained liquor and Intensive Care Nursery admission. Results: Two-graph receiver operating characteristic (TG-ROC) analysis showed optimal specificity, and sensitivity for predicting adverse neonatal outcomes was a scalp lactate level above 4.2 mmol/L. Conclusions: Fetal blood sampling remains the standard for further investigating-non-reassuring cardiotocograph (CTG) traces. Even so, it is a poor predictor of fetal outcomes. Scalp lactate has been shown to be at least as good a predictor as scalp pH, with the advantages of being easier, cheaper and with a lower rate of technical failure. Our study, found that a cut off fetal scalp lactate level of 4.2 mmol/L, in combination with an assessment of the entire clinical picture, is a useful tool in identifying those women who need intervention.