3 resultados para Hypercapnia

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: CO2 monitoring is recommended for thoracic telescopic procedures and for spontaneous breathing general anesthesia in children. During flexible bronchoscopy (FB) in children, the various currently available methods of CO2 measurements are limited. The CO2 falls and increases have been reported in FB but it is unknown whether airway lesions predispose to CO2 change. The aim of this study was to describe and validate endoscopic intratracheal CO2 measurements in children undergoing FB under spontaneously breathing GA. Methods: Endtidal CO2 (PECO2) measurements at the start (Start-CO2) and end (End-CO2) of FB on 100 consecutive children were performed using a newly designed endoscopic intratracheal method. To validate the method blood gas sampling was simultaneously performed in 28 children and results analyzed using the Bland and Altman method, intraclass correlation and 95% range for repeatability. Results: End-CO2 and CO2-change (End-CO2 minus Start-CO2) were significantly different in children with airway lesions (CO2 change: no lesion = 3 mmHg, extrathoracic airway lesion = 4.5, intrathoracic airway lesion = 8, P = 0.038). There was no significant difference in Start-CO2 values among the groups. CO2-change in those aged > 12 months was similar to those >12 months. Intratracheal CO2 measurements were comparable with arterial blood values in the Bland and Altman plots. The intraclass correlation was 0.69 and 95% range for repeatability was 3.7-4.17 mmHg. Conclusions: Midtracheal PECO2 provides a useful estimate of PaCO2 for monitoring the respiratory status of children undergoing FB. The presence of airway lesions rather than age is associated with significant increased PCO2 rise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuromuscular respiratory failure is not considered to be a clinical feature of chronic inflammatory demyelinating polyneuropathy (CIDP). We present 4 patients with CIDP who required respiratory assistance and mechanical ventilation. Two patients needed emergent intubation and one patient lapsed in a stupor from hypercapnia. Respiratory failure in CIDP should be considered exceptional, but more formal studies in CIDP may be needed to assess its prevalence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims Previous isobolographic analysis revealed that coadministration of morphine and oxycodone produces synergistic antinociception in laboratory rodents. As both opioids can produce ventilatory depression, this study was designed to determine whether their ventilatory effects were synergistic when coadministered to healthy human subjects. Methods A placebo-controlled, randomized, crossover study was performed in 12 male volunteers. Ventilatory responses to hypoxaemia and hypercapnia were determined from 1-h intravenous infusions of saline ('placebo'), 15 mg morphine sulphate (M), 15 mg oxycodone hydrochloride (O), and their combination in the dose ratios of 1 : 2, 1 : 1, 2 : 1. Drug and metabolite concentrations in serial peripheral venous blood samples were measured by high-performance liquid chromatography-MS/MS. Results 'Placebo' treatment was without significant ventilatory effects. There were no systematic differences between active drug treatments on either the slopes or intercepts of the hypoxaemic and hypercapnia ventilation responses. During drug treatment, the mean minute ventilation at PETCO2 = 55 mmHg (V-E55) decreased to 74% of the subjects' before treatment values (95% confidence interval 62, 87), 68% (57, 80), 69% (59, 79), 68% (63, 73), and 61% (52, 69) for M15, M10/O5, M7.5/O7.5, M5/O10 and O15, respectively. Recovery was more prolonged with increasing oxycodone doses, corresponding to its greater potency and lower clearance compared with morphine. Conclusions Although adverse ventilatory effects of these drugs were found as expected, no unexpected or disproportionate effects of any of the morphine and oxycodone treatments were found that might impede their use in combination for pain management.