25 resultados para Histologic lip measurements and analyses

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In small estuaries, the predictions of scalar dispersion can rarely be predicted accurately because of a lack of fundamental understanding of the turbulence structure. Herein detailed turbulence measurements and suspended sediment concentrations were conducted simultaneously and continuously at high-frequency for 50 hours per investigation in a small subtropical estuary with semi-diurnal tides. The data analyses provided an unique characterisation of the turbulent mixing processes and suspended sediment fluxes. The turbulence was neither homogeneous nor isotropic, and it was not a Gaussian process. The integral time scales for turbulence and suspended sediment concentration were about equal during flood tides, but differed significantly during ebb tides. The field experiences showed that the turbulence measurements must be conducted at high-frequency to characterise the small eddies and the viscous dissipation process, while a continuous sampling was necessary to characterise the time-variations of the instantaneous velocity field, Reynolds stress tensor and suspended sediment flux during the tidal cycles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Free-piston-driven expansion tubes are capable of generating flaw conditions over a wide range of enthalpies ranging from orbital up to superorbital velocities. Initial optical measurements aimed at investigating the flow in such a facility are presented. Emission studies were used to identify impurities in the how and to investigate spectral regions that are accessible by optical techniques. At moderate enthalpies, it was found that significant radiation resulted from metallic contaminants. At high enthalpies, the spectrum consisted of a number of atomic lines together with a broadband background component indicative of the presence of electrons. The presence of this radiation may limit the applicability of optical techniques that require spectral regions free from the influence of atomic transitions or background radiation. Emission spectroscopy (through Stark broadened hydrogen lines) and two-wavelength holographic interferometry were used to measure the electron number density behind a bow shock on a blunt body at conditions where significant ionization was observed. They yielded average concentrations of (3 +/- 1) x 10(17) cm(-3) from the emission measurements and (3.8 +/- 0.6) x 10(17) cm(-3) from the interferometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a review of recent developments on entanglement and nonclassical effects in collective two-atom systems and present a uniform physical picture of the many predicted phenomena. The collective effects have brought into sharp focus some of the most basic features of quantum theory, such as nonclassical states of light and entangled states of multiatom systems. The entangled states are linear superpositions of the internal states of the system which cannot be separated into product states of the individual atoms. This property is recognized as entirely quantum-mechanical effect and have played a crucial role in many discussions of the nature of quantum measurements and, in particular, in the developments of quantum communications. Much of the fundamental interest in entangled states is connected with its practical application ranging from quantum computation, information processing, cryptography, and interferometry to atomic spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparisons are made between experimental measurements and numerical simulations of ionizing flows generated in a superorbital facility. Nitrogen, with a freestream velocity of around 10 km/s, was passed over a cylindrical model, and images were recorded using two-wavelength holographic interferometry. The resulting density, electron concentration, and temperature maps were compared with numerical simulations from the Langley Research Center aerothermodynamic upwind relaxation algorithm. The results showed generally good agreement in shock location and density distributions. Some discrepancies were observed for the electron concentration, possibly, because simulations were of a two-dimensional flow, whereas the experiments were likely to have small three-dimensional effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bulk free radical copolymerizations of 2-hydroxyethyl methacrylate (HEMA) with n-butyl methacrylate (BMA) or cyclohexyl methacrylate (CHMA) were studied over the composition mole fraction interval of 0-1 for HEMA in the monomer feed. The C-13 NMR (125 MHz) spectra of the copolymers were analysed to determine the copolymer composition and the stereochemical configuration of the copolymers. The terminal model reactivity ratios of HEMA and BMA were found to be r(HEMA) = 1.73 and r(BMA) = 0.65 and for HEMA and CHMA, r(HEMA) = 1.26 and r(CHMA) = 0.31. The BMA and CHMA homopolymers were found to be predominantly syndiotactic with isotacticity parameters of theta(BB) = 0.18 and theta(CC) = 0.19, respectively. The copolymers were also found to be predominantly syndiotactic, indicating a strong tendency for racemic additions of the monomers in the formation of the copolymers. The diffusion of water into cylinders of poly(HEMA-co-BMA) and poly(HEMA-co-CHMA) was studied over a range of copolymer compositions and was found to be Fickian. The diffusion coefficients of water at 37 degrees C were determined from swelling measurements and were found to vary from 1.72 x 10(-11) m(2) s(-1) for polyHEMA to 0.97 x 10(-11) m(2) s(-1) for poly(HEMA-co-BMA) having a mole fraction F-HEMA = 0.80 and to 0.91 x 10(-11) m(2) s(-1) for a poly(HEMA-co-CHMA) also having F-HEMA = 0.80. The mass of water absorbed at equilibrium relative to the mass of dry polymer varied from 58.8 for polyHEMA to 27.2% for poly(HEMA-co-BMA) having F-HEMA = 0.85 and to 21.3% for poly(HEMA-co-CHMA) having F-HEMA = 0.80. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogels with various compositions of polyvinyl alcohol (PVA) and poly(1-vinyl-2-pyrrolidinone) (PVP) were prepared by irradiating mixtures of PVA and PVP in aqueous solutions with gamma-rays from Co-60 sources at room temperature. The states of water in the hydrogels were characterized using DSC and NMR T-2 relaxation measurements and the kinetics of water diffusion in the hydrogels were studied by sorption experiments and NMR imaging. The DSC endothermic peaks in the temperature range -10 to +10 degrees C implied that there are at least two kinds of freezable water present in the matrix. The difference between the total water content and the freezable water content was refer-red to as bound water, which is not freezable. The weight fraction of water at which only nonfreezable water is present in a hydrogel with F-VP = 0.19 has been estimated to be g(H2O)/g(Polymer) = 0.375. From water sorption experiments, it was demonstrated that the early stage of the diffusion of water into the hydrogels was Fickian. A curve-fit of the early-stage experimental data to the Fickian model allowed determination of the water diffusion coefficient, which was found to lie between 1.5 x 10(-11) m(2) s(-1) and 4.5 x 10(-11) m(2) s(-1), depending on the polymer composition, the cross-link density, and the temperature. It was also found that the energy barrier for diffusion of water molecules into PVA/PVP hydrogels was approximate to 24 kJ mol(-1). Additionally, the diffusion coefficients determined from NMR imaging of the volumetric swelling of the gels agreed well with the results obtained by the mass sorption method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents field measurements and numerical simulations of groundwater dynamics in the intertidal zone of a sandy meso-tidal beach. The study, focusing on vertical hydraulic gradients and pore water salinities, reveals that tides and waves provide important forcing mechanisms for flow and salt transport in the nearshore aquifer. Such forcing, interacting with the beach morphology, enhances the exchange between the aquifer and ocean. The spatial and temporal variations of vertical hydraulic gradients demonstrate the complexity and dynamic nature of the processes and the extent of mixing between fresh groundwater and seawater in a subterranean estuary''. These results provide evidence of a potentially important reaction zone in the nearshore aquifer driven by oceanic oscillations. Land-derived contaminants may undergo important biogeochemical transformations in this zone prior to discharge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few prospective data from the Asia Pacific region are available relating body mass index to the risk of diabetes. Our objective was to provide reliable age, sex and region specific estimates of the associations between body mass index and diabetes. Twenty-seven cohort studies from Asia, New Zealand and Australia, including 154,989 participants, contributed 1,244,793 person-years of follow-up. Outcome data included a combination of incidence of diabetes (based on blood glucose measurements) and fatal diabetes events. Hazard ratios were calculated from Cox models, stratified by sex and cohort, and adjusted for age at risk and smoking. During follow-up (mean = 8 years), 75 fatal diabetes events and 242 new cases of diabetes were documented. There were continuous positive associations between baseline body mass index and risk of diabetes with each 2 kg/m(2) lower body mass index associated with a 27% (23-30%) lower risk of diabetes. The associations were stronger in younger age groups, and regional comparisons demonstrated slightly stronger associations in Asian than in Australasian cohorts (P = 0.04). This overview provides evidence of a strong continuous association between body mass index and diabetes in the Asia Pacific region. The results indicate considerable potential for reduction in incidence of diabetes with population-wide lowering of body mass index in this region.