12 resultados para High throughput nucleotide sequencing

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a significant clinical need to identify novel ligands with high selectivity and potency for GABA(A), GABA(C) and glycine receptor Cl- channels. Two recently developed, yellow fluorescent protein variants (YFP-I152L and YFP-V163S) are highly sensitive to quench by small anions and are thus suited to reporting anionic influx into cells. The aim of this study was to establish the optimal conditions for using these constructs for high-throughput screening of GABA(A), GABA(C) and glycine receptors transiently expressed in HEK293 cells. We found that a 70% fluorescence reduction was achieved by quenching YFP-I152L with a 10 s influx of I- ions, driven by an extemal I- concentration of at least 50 mM. The fluorescence quench was rapid, with a mean time constant of 3 s. These responses were similar for all anion receptor types studied. We also show the assay is sufficiently sensitive to measure agonist and antagonist concentration-responses using either imaging- or photomultiplier-based detection systems. The robustness, sensitivity and low cost of this assay render it suited for high-throughput screening of transiently expressed anionic ligand-gated channels. (c) 2005 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent discoveries of different modes of exocytosis and a plethora of molecules involved in neurotransmitter release has resulted in demand for more rapid and efficient methods for monitoring endogenous glutamate release from various tissue sources. In this article, we describe a high throughput microplate version of the enzyme-linked fluorescence detection method for the measurement of released glutamate, which utilises glutamate dehydrogenase, and the reduction of NADP to NADPH. Previous versions of this method rely upon cuvette-based fluorimeters for detection that are limited by large sample volumes and small numbers of samples that can be measured simultaneously. Comparison between the two methods shows that the microplate assay has comparable performance to the cuvette-based assay but has the capacity to analyse many times more samples in a given run. This increased capacity provides improved experimental design opportunities, higher experimental throughput and better comparison between experimental conditions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flow cytometry, in combination with advances in bead coding technologies, is maturing as a powerful high-throughput approach for analyzing molecular interactions. Applications of this technology include antibody assays and single nucleotide polymorphism mapping. This review describes the recent development of a microbead flow cytometric approach to analyze RNA-protein interactions and discusses emerging bead coding strategies that together will allow genome-wide identification of RNA-protein complexes. The microbead flow cytometric approach is flexible and provides new opportunities for functional genomic studies and small-molecule screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography coupled by an electrospray ion source to a tandem mass spectrometer (HPLC-EST-MS/ MS) is the current analytical method of choice for quantitation of analytes in biological matrices. With HPLC-ESI-MS/MS having the characteristics of high selectivity, sensitivity, and throughput, this technology is being increasingly used in the clinical laboratory. An important issue to be addressed in method development, validation, and routine use of HPLC-ESI-MS/MS is matrix effects. Matrix effects are the alteration of ionization efficiency by the presence of coeluting substances. These effects are unseen in the chromatograrn but have deleterious impact on methods accuracy and sensitivity. The two common ways to assess matrix effects are either by the postextraction addition method or the postcolumn infusion method. To remove or minimize matrix effects, modification to the sample extraction methodology and improved chromatographic separation must be performed. These two parameters are linked together and form the basis of developing a successful and robust quantitative HPLC-EST-MS/MS method. Due to the heterogenous nature of the population being studied, the variability of a method must be assessed in samples taken from a variety of subjects. In this paper, the major aspects of matrix effects are discussed with an approach to address matrix effects during method validation proposed. (c) 2004 The Canadian Society of Clinical Chemists. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large-scale gene discovery has been performed for the grass fungal endophytes Neotyphodium coenophialum, Neotyphodium lolii, and Epichloe festucae. The resulting sequences have been annotated by comparison with public DNA and protein sequence databases and using intermediate gene ontology annotation tools. Endophyte sequences have also been analysed for the presence of simple sequence repeat and single nucleotide polymorphism molecular genetic markers. Sequences and annotation are maintained within a MySQL database that may be queried using a custom web interface. Two cDNA-based microarrays have been generated from this genome resource, They permit the interrogation of 3806 Neotyphodium genes (Nchip (TM) rnicroarray), and 4195 Neotyphodium and 920 Epichloe genes (EndoChip (TM) microarray), respectively. These microarrays provide tools for high-throughput transcriptome analysis, including genome-specific gene expression studies, profiling of novel endophyte genes, and investigation of the host grass-symbiont interaction. Comparative transcriptome analysis in Neotyphodium and Epichloe was performed. (c) 2006 Elsevier

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The BRAF gene is frequently somatically altered in malignant melanoma. A majority of variations are at the valine 600 residue leading to a V600E substitution that constitutively activates the kinase. We screened 4000 patient and control DNAs for germ-line variations at the valine 600 residue. Methods: We developed a novel assay by adapting single-base variation assays and software for MALDI-TOF (matrix-assisted laser desorption/ionization time-of-flight) mass spectrometry to screen for all 5 reported variants at codon 600 of the BRAF gene. We screened a case-control collection comprising samples from 1082 melanoma patients and 154 of their unaffected relatives from 1278 families and from 2744 individuals from 659 unselected twin families with no history of melanoma. A panel of 66 melanoma cell lines was used for variation-positive controls. Results: All melanoma cell lines that we had found previously to carry a codon 600 variation were verified in this study. Three of the 4 possible variants (V600E n = 47, V600K n = 2, V600R n = 1) were detected, but no case of V600D was available. No germ-line variants were found in the samples from the 3980 melanoma patients or from the control individuals. Conclusions: This new assay is a high-throughput, automated alternative to standard sequencing and can be used as a rapid initial screen for somatic variants associated with melanoma. Germ-line variants at valine 600 are unlikely to exist and do not contribute to the reported role of the BRAF gene in melanoma predisposition. (c) 2006 American Association for Clinical Chemistry.