78 resultados para HORIZONTAL CONVECTIVE ROLLS
em University of Queensland eSpace - Australia
Theoretical and numerical analyses of convective instability in porous media with upward throughflow
Resumo:
Exact analytical solutions have been obtained for a hydrothermal system consisting of a horizontal porous layer with upward throughflow. The boundary conditions considered are constant temperature, constant pressure at the top, and constant vertical temperature gradient, constant Darcy velocity at the bottom of the layer. After deriving the exact analytical solutions, we examine the stability of the solutions using linear stability theory and the Galerkin method. It has been found that the exact solutions for such a hydrothermal system become unstable when the Rayleigh number of the system is equal to or greater than the corresponding critical Rayleigh number. For small and moderate Peclet numbers (Pe less than or equal to 6), an increase in upward throughflow destabilizes the convective flow in the horizontal layer. To confirm these findings, the finite element method with the progressive asymptotic approach procedure is used to compute the convective cells in such a hydrothermal system. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
In order to investigate the effect of material anisotropy on convective instability of three-dimensional fluid-saturated faults, an exact analytical solution for the critical Rayleigh number of three-dimensional convective flow has been obtained. Using this critical Rayleigh number, effects of different permeability ratios and thermal conductivity ratios on convective instability of a vertically oriented three-dimensional fault have been examined in detail. It has been recognized that (1) if the fault material is isotropic in the horizontal direction, the horizontal to vertical permeability ratio has a significant effect on the critical Rayleigh number of the three-dimensional fault system, but the horizontal to vertical thermal conductivity ratio has little influence on the convective instability of the system, and (2) if the fault material is isotropic in the fault plane, the thermal conductivity ratio of the fault normal to plane has a considerable effect on the critical Rayleigh number of the three-dimensional fault system, but the effect of the permeability ratio of the fault normal to plane on the critical Rayleigh number of three-dimensional convective flow is negligible.
Resumo:
Exact analytical solutions of the critical Rayleigh numbers have been obtained for a hydrothermal system consisting of a horizontal porous layer with temperature-dependent viscosity. The boundary conditions considered are constant temperature and zero vertical Darcy velocity at both the top and bottom of the layer. Not only can the derived analytical solutions be readily used to examine the effect of the temperature-dependent viscosity on the temperature-gradient driven convective flow, but also they can be used to validate the numerical methods such as the finite-element method and finite-difference method for dealing with the same kind of problem. The related analytical and numerical results demonstrated that the temperature-dependent viscosity destabilizes the temperature-gradient driven convective flow and therefore, may affect the ore body formation and mineralization in the upper crust of the Earth. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
Cytoplasmic incompatibility (CI) in Drosophila simulans is related to infection of the germ line by a rickettsial endosymbiont (genus Wolbachia). Wolbachia were transferred by microinjection of egg cytoplasm into uninfected eggs of both D. simulans and D. melanogaster to generate infected populations. Transinfected strains of D. melanogaster with lower densities of Wolbachia than the naturally infected D. simulans strain did not express high levels of CI. However, transinfected D. melanogaster egg cytoplasm, transferred back into D. simulans, generated infected populations that expressed CI at levels near those of the naturally infected strain. A transinfected D. melanogaster line selected for increased levels of CI expression also displayed increased symbiont densities. These data suggest that a threshold level of infection is required for normal expression of CI and that host factors help determine the density of the symbiont in the host.
Resumo:
A parametric study is carried out to investigate how geological inhomogeneity affects the pore-fluid convective flow field, the temperature distribution, and the mass concentration distribution in a fluid-saturated porous medium. The related numerical results have demonstrated that (1) the effects of both medium permeability inhomogeneity and medium thermal conductivity inhomogeneity are significant on the pore-fluid convective flow and the species concentration distribution in the porous medium; (2) the effect of medium thermal conductivity inhomogeneity is dramatic on the temperature distribution in the porous medium, but the effect of medium permeability inhomogeneity on the temperature distribution may be considerable, depending on the Rayleigh number involved in the analysis; (3) if the coupling effect between pore-fluid flow and mass transport is weak, the effect of the Lewis number is negligible on the pore-fluid convective flow and temperature distribution, hut it is significant on the species concentration distribution in the medium.
Resumo:
No abstract
Resumo:
Drainage of a saturated horizontal aquifer following a sudden drawdown is reanalyzed using the Boussinesq equation. The effect of the finite length of the aquifer is considered in detail. An analytical approximation based on a superposition principle yields a very good estimate of the outflow when compared to accurate numerical solutions. An illustration of the new analytical approach to analyze basin-scale field data is used to demonstrate possible field applications of the new solution.
Resumo:
We conduct a theoretical analysis to investigate the convective instability of 3-D fluid-saturated geological fault zones when they are heated uniformly from below. In particular, we have derived exact analytical solutions for the critical Rayleigh numbers of different convective flow structures. Using these critical Rayleigh numbers, three interesting convective flow structures have been identified in a geological fault zone system. It has been recognized that the critical Rayleigh numbers of the system have a minimum value only for the fault zone of infinite length, in which the corresponding convective flow structure is a 2-D slender-circle flow. However, if the length of the fault zone is finite, the convective flow in the system must be 3-D. Even if the length of the fault zone is infinite, since the minimum critical Rayleigh number for the 2-D slender-circle flow structure is so close to that for the 3-D convective flow structure, the system may have almost the same chance to pick up the 3-D convective flow structures. Also, because the convection modes are so close for the 3-D convective flow structures, the convective flow may evolve into the 3-D finger-like structures, especially for the case of the fault thickness to height ratio approaching zero. This understanding demonstrates the beautiful aspects of the present analytical solution for the convective instability of 3-D geological fault zones, because the present analytical solution is valid for any value of the ratio of the fault height to thickness. Using the present analytical solution, the conditions, under which different convective flow structures may take place, can be easily determined.
Resumo:
Perceived slant was measured for horizontal lines aligned on one side and of varying lengths whose length disparity was either a constant linear amount for all lines (consistent with uniocular occlusion) or proportional to line length (consistent with global slant). Although the disparity of any line was ambiguous with respect to these two possibilities, slant of individual lines did not occur in the former case, but a subjective contour in depth was reported along the alignment. For proportional disparity of the set, global slant was seen. Adding a constant length to each line on the invalid eye for occlusion resulted in multiple slants. Smooth uniocular variations in alignment shape elicited subjective contours slanting or curving in depth. Global context can disambiguate the depth status of individual disparate lines. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
We conduct a theoretical analysis to investigate the double diffusion-driven convective instability of three-dimensional fluid-saturated geological fault zones when they are heated uniformly from below. The fault zone is assumed to be more permeable than its surrounding rocks. In particular, we have derived exact analytical solutions to the total critical Rayleigh numbers of the double diffusion-driven convective flow. Using the corresponding total critical Rayleigh numbers, the double diffusion-driven convective instability of a fluid-saturated three-dimensional geological fault zone system has been investigated. The related theoretical analysis demonstrates that: (1) The relative higher concentration of the chemical species at the top of the three-dimensional geological fault zone system can destabilize the convective flow of the system, while the relative lower concentration of the chemical species at the top of the three-dimensional geological fault zone system can stabilize the convective flow of the system. (2) The double diffusion-driven convective flow modes of the three-dimensional geological fault zone system are very close each other and therefore, the system may have the similar chance to pick up different double diffusion-driven convective flow modes, especially in the case of the fault thickness to height ratio approaching 0. (3) The significant influence of the chemical species diffusion on the convective instability of the three-dimensional geological fault zone system implies that the seawater intrusion into the surface of the Earth is a potential mechanism to trigger the convective flow in the shallow three-dimensional geological fault zone system.
Resumo:
Numerical methods are used to simulate the double-diffusion driven convective pore-fluid flow and rock alteration in three-dimensional fluid-saturated geological fault zones. The double diffusion is caused by a combination of both the positive upward temperature gradient and the positive downward salinity concentration gradient within a three-dimensional fluid-saturated geological fault zone, which is assumed to be more permeable than its surrounding rocks. In order to ensure the physical meaningfulness of the obtained numerical solutions, the numerical method used in this study is validated by a benchmark problem, for which the analytical solution to the critical Rayleigh number of the system is available. The theoretical value of the critical Rayleigh number of a three-dimensional fluid-saturated geological fault zone system can be used to judge whether or not the double-diffusion driven convective pore-fluid flow can take place within the system. After the possibility of triggering the double-diffusion driven convective pore-fluid flow is theoretically validated for the numerical model of a three-dimensional fluid-saturated geological fault zone system, the corresponding numerical solutions for the convective flow and temperature are directly coupled with a geochemical system. Through the numerical simulation of the coupled system between the convective fluid flow, heat transfer, mass transport and chemical reactions, we have investigated the effect of the double-diffusion driven convective pore-fluid flow on the rock alteration, which is the direct consequence of mineral redistribution due to its dissolution, transportation and precipitation, within the three-dimensional fluid-saturated geological fault zone system. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A traveling wave of BaSO4 in the chlorite-thiourea reaction has shown concentric precipitation patterns upon being triggered by the autocatalyst HOCl. The precipitation patterns show circular rings of alternate null and full precipitation regions. This self-organization appears to be the result of the formation of a convective torus. The formation of the convective torus can be described as a Benard-Marangoni instability with lateral heating.
Resumo:
The relative potential of the pathogenic fungi Beauveria bassiana and Zoophthora radicans for use as autodisseminated biological control agents of the diamondback moth (Plutella xylostella) was compared. The LC50 of B. bassiana conidia to third instar larvae was 499 conidia/mm(2) of leaf surface and individual cadavers of mycosed fourth instar larvae yielded a mean of 67.5 X 10(6) (+/- 7.5 x 10(6)) conidia. All concentrations of B. bassiana tested in inoculation chambers (0.24, 2.4, and 6.2 mug/mm(2)) induced 100% mortality in adult male moths within 7 days. The times to death and sporulation were concentration and exposure duration dependent. A standard procedure for inoculating male moths resulted in > 85% mortality from Z. radicans and > 93% mortality from B. bassiana. Pairing of inoculated males with clean moths of both sexes yielded higher rates of passive transmission of B. bassiana than Z. radicans, but there was no evidence for sexual transmission of either pathogen. Similarly, B. bassiana was more effectively transmitted from inoculated male moths to larvae foraging on whole plants. Single sporulating cadavers producing B. bassiana or Z. radicans conidia placed on plants infested with larvae resulted in a similar rate of transmission for both pathogens. However, an increase of the density of sporulating cadavers from one to three/plant increased Z. radicans transmission (greater than fourfold) but had no effect on B. bassiana transmission. Simultaneous inoculations of larvae with conidia of both fungi reduced the mortality induced by each pathogen, the reduction being most acute for B. bassiana-induced mortality. Inoculation of adults with both fungi showed that, at concentrations required for effective passive transmission to larvae, B. bassiana severely inhibited Z. radicans mycosis in adults. (C) 2001 Academic Press.
Resumo:
Mixed confined and unconfined groundwater flow occurs in a bounded initially dry aquifer when the hydraulic head at the side boundary suddenly rises above the elevation of the aquifer's top boundary. The flow problem as modelled by the Boussinesq equation is non-trivial because of the involvement of two moving boundaries. The transformed equation (based on a similarity transformation) can, however, be dealt with more easily. Here, we present an approximate analytical solution for this flow problem. The approximate solution is compared with an 'exact' numerical solution and found to be a very accurate description for describing the mixed confined and unconfined flow in the confined aquifer. (C) 2002 Elsevier Science B.V. All rights reserved.