29 resultados para Frequency Bioelectrical-impedance

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, nonlinear curve fitting. An alternative fitting method is described that uses only the magnitude of the measured impedances at four selected frequencies. The two methods showed excellent agreement when compared using data obtained both from measurements of equivalent circuits and of humans. These results suggest that operational equivalence to a technically complex, frequency-scanning, phase-sensitive BIS analyser could be achieved from a simple four-frequency, impedance-only analyser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectional observational study in 84 term and near-term healthy neonates less than 12 h postpartum. Whole body and cerebral MFBIA measurements were performed at the bedside in the post-natal ward. Gestational age, post-natal age, gender, birthweight, head circumference and foot length measures were recorded. Reference values for impedance at the characteristic frequency (Z(C)) and resistance at zero frequency (R-0) are reported for whole body and cerebral impedance. Significant correlations (p < 0.05) were observed between whole body impedance and birthweight, footlength and head circumference. Females had a significantly higher whole body R0 than males. Cerebral impedance did not correlate significantly with any of the demographic measures and therewere no gender differences observed for cerebral impedance. The reference range for whole body multi-frequency bio-impedance values in term and near-term infants within the first 12 h postpartum can be calculated from the footlength (FL) using the following equations: Z(C) = (942.9 - 4.818* FL) +/- 124.6 Omega; R-0 = (1042 - 4.520(*)FL) +/- 135.5 Omega. For cerebral impedance the reference range is 29.5-48.7 Omega for Z(C) and 33.7-58.0 Omega for R-0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detailed analysis of body composition in children has helped to understand changes that occur in growth and disease. Bioelectrical impedance analysis (BIA) has gained popularity as a simple, non-invasive and inexpensive tool of body composition assessment. Being an indirect technique, prediction equations have to be used in the assessment of body composition. There are many prediction equations available in the literature for the assessment of body composition from BIA. This study aims to cross-validate some of those prediction equations to determine the suitability of their use on Australian children of white Caucasian and Sri Lankan origins. Height, weight and BIA were measured. Total body water was measured using the isotope dilution method (D2O). Fat-mass (FM) and %FM were estimated from BIA using ten prediction equations described in the literature. Five to 14.99-year-old healthy, 96 white Caucasians and 42 Sri Lankan children were studied. The equation of Schaefer et al was the most suitable prediction equation for this group with the lowest mean bias for %FM assessment in both Caucasian (–1.0±9.6%) and Sri Lankan (1.6±5.2%) children and the fat content of the individuals did not influence the predictions by this equation. Impedance index (height2/impedance) explained for 80% of TBW in white Caucasians and 93% in Sri Lankans and figures were similar for the prediction of FFM. We conclude that BIA can be used effectively in the assessment of body composition in children. However, for the assessment of body composition using BIA, either prediction equations should be derived to suit the local populations or existing equations should be cross-validated to determine their suitability before their application.