48 resultados para Fluxometria por laser-Doppler
em University of Queensland eSpace - Australia
Resumo:
We investigate the effect of coexisting transverse modes on the operation of self-mixing sensors based on vertical-cavity surface-emitting lasers (VCSELs). The effect of multiple transverse modes on the measurement of displacement and distance were examined by simulation and in laboratory experiment. The simulation model shows that the periodic change in the shape and magnitude of the self-mixing signal with modulation current can be properly explained by the different frequency-modulation coefficients of the respective transverse modes in VCSELs. The simulation results are in excellent agreement with measurements performed on single-mode and multimode VCSELs and on self-mixing sensors based on these VCSELs.
Resumo:
Hypersensitivity to a variety of sensory Stimuli is a feature of persistent whiplash associated disorders (WAD). However, little is known about sensory disturbances from the time Of injury until transition to either recovery or symptom persistence. Quantitative sensory testing (pressure and thermal pain thresholds, the brachial plexus provocation test), the sympathetic vasoconstrictor reflex and psychological distress (GHQ-28) were prospectively measured in 76 whiplash Subjects within 1 month of injury and then 2, 3 and 6 months post-injury. Subjects were classified at 6 months post-injury using scores on the Neck Disability Index: recovered (30). Sensory and sympathetic nervous system tests were also measured in 20 control subjects. All whiplash groups demonstrated local mechanical hyperalgesia in the cervica spine at 1 month post-injury. This hyperalgesia persisted in those with moderate/severe symptoms at 6 months but resolved by 2 months in those who had recovered or reported persistent mild symptoms. Only those with persistent moderate/severe symptoms at 6 months demonstrated generalised hypersensitivity to all sensory tests. These changes Occurred within 1 month of injury and remained Unchanged throughout the Study period. Whilst no significant group differences were evident for the sympathetic vasoconstrictor response, the moderate/severe group showed a tendency for diminished sympathetic reactivity. GHQ-28 scores of the moderate/severe group were higher than those of the other two groups. The differences in GHQ-28 did not impact on any of the sensory measures. These findings suggest that those with persistent moderate/severe symptoms at 6 months display, soon after injury, generalised hypersensitivity suggestive of changes in central pain processing mechanisms. This phenomenon did not Occur in those who recover or those with persistent mild symptoms. (C) 2003 International Association for the Study of Pain. Published by Elsevier Science B.V. All rights reserved.
Resumo:
Background: The purpose of the present study was to compare the effectiveness of three burns dressings (TransCyte, a bio-engineered skin substitute; Biobrane; and Silvazine cream (silver sulphadiazine and 0.2% chlorhexidine)), in treating children with partial-thickness burns. The primary objective was to determine the days until greater than or equal to90% re-epithelialization. The secondary objectives were to evaluate the number of wounds requiring autografting and the number of dressing changes/local wound care required. Methods: Study wounds were identified on each patient and the patients were randomized to receive TransCyte or Biobrane or Silvazine. Assessment of study wound closure began at 2 days after treatment and continued at least every other day thereafter until the wounds re-epithelialized or were autografted. A laser Doppler imaging system was used as an adjunct to assessing the depth of the burn. Results: Thirty-three patients with 58 wound sites enrolled in the study (TransCyte, n = 20, Biobrane, n = 17; Silvazine, n = 21). Mean time to re-epithelialization was 7.5 days for TransCyte, 9.5 days for Biobrane, and 11.2 days for Silvazine. The number of wounds requiring autografting were 5/21 (24%) for Silvazine, 3/17 (17%) for Biobrane, and 1/20 (5%) for TransCyte. Conclusions: When used in partial-thickness burns in children, TransCyte promotes fastest re-epithelialization and required less overall dressings then Biobrane or Silvazine. Patients who received Silvazine or Biobrane require more autografting than those treated with TransCyte.
Resumo:
We present a new method of laser frequency locking in which the feedback signal is directly proportional to the detuning from an atomic transition, even at detunings many times the natural linewidth of the transition. Our method is a form of sub-Doppler polarization spectroscopy, based on measuring two Stokes parameters (I-2 and I-3) of light transmitted through a vapor cell. It extends the linear capture range of the lock loop by as much as an order of magnitude and provides frequency discrimination equivalent to or better than those of other commonly used locking techniques. (C) 2004 Optical Society of America
Resumo:
A narrow absorption feature in an atomic or molecular gas (such as iodine or methane) is used as the frequency reference in many stabilized lasers. As part of the stabilization scheme an optical frequency dither is applied to the laser. In optical heterodyne experiments, this dither is transferred to the RF beat signal, reducing the spectral power density and hence the signal to noise ratio over that in the absence of dither. We removed the dither by mixing the raw beat signal with a dithered local oscillator signal. When the dither waveform is matched to that of the reference laser the output signal from the mixer is rendered dither free. Application of this method to a Winters iodine-stabilized helium-neon laser reduced the bandwidth of the beat signal from 6 MHz to 390 kHz, thereby lowering the detection threshold from 5 pW of laser power to 3 pW. In addition, a simple signal detection model is developed which predicts similar threshold reductions.
Resumo:
The transient statistics of a gain-switched coherently pumped class-C laser displays a linear correlation between the first passage time and subsequent peak intensity. Measurements are reported showing a positive or negative sign of this linear correlation, controlled through the switching time and the laser detuning. Further measurements of the small-signal laser gain combined with calculations involving a three-level laser model indicate that this sign fundamentally depends upon the way the laser inversion varies during the gain switching, despite the added dynamics of the laser polarization in the class-C laser. [S1050-2947(97)07112-6].
Resumo:
We consider one source of decoherence for a single trapped ion due to intensity and phase fluctuations in the exciting laser pulses. For simplicity we assume that the stochastic processes involved are white noise processes, which enables us to give a simple master equation description of this source of decoherence. This master equation is averaged over the noise, and is sufficient to describe the results of experiments that probe the oscillations in the electronic populations as energy is exchanged between the internal and electronic motion. Our results are in good qualitative agreement with recent experiments and predict that the decoherence rate will depend on vibrational quantum number in different ways depending on which vibrational excitation sideband is used.
Resumo:
Control of chaos in the single-mode optically pumped far-infrared (NH3)-N-15 laser is experimentally demonstrated using continuous time-delay control. Both the Lorenz spiral chaos and the detuned period-doubling chaos exhibited by the laser have been controlled. While the laser is in the Lorenz spiral chaos regime the chaos has been controlled both such that the laser output is cw, with corrections of only a fraction of a percent necessary to keep it there, and to period one. The laser has also been controlled while in the period-doubling chaos regime, to both the period-one and -two states.
Resumo:
In a recent paper Meyer and Yeoman [Phys. Rev. Lett. 79, 2650 (1997)] have shown that the resonance fluorescence from two atoms placed in a cavity and driven by an incoherent field can produce an interference pattern with a dark center. We study the fluorescence from two coherently driven atoms in free space and show that this system can also produce an interference pattern with a dark center. This happens when the atoms are in nonequivalent positions in the driving: field, i.e., the atoms experience different intensities and phases of the driving field. We discuss the role of the interatomic interactions in this process and find that the interference pattern with a dark center results from the participation of the antisymmetric state in the dynamics of the driven two-atom system.
Resumo:
There are some interesting connections between the theory of quantum computation and quantum measurement. As an illustration, we present a scheme in which an ion trap quantum computer can be used to make arbitrarily accurate measurements of the quadrature phase variables for the collective vibrational motion of the ion. We also discuss some more general aspects of quantum computation and measurement in terms of the Feynman-Deutsch principle.
Resumo:
The free running linewidth of an external cavity grating feedback diode laser is on the order of a few megahertz and is limited by the mechanical and acoustic vibrations of the external cavity. Such frequency fluctuations can be removed by electronic feedback. We present a hybrid stabilisation technique that uses both a Fabry-Perot confocal cavity and an atomic resonance to achieve excellent short and long term frequency stability. The system has been shown to reduce the laser linewidth of an external cavity diode laser by an order of magnitude to 140 kHz, while limiting frequency excursions to 60 kHz relative to an absolute reference over periods of several hours. The scheme also presents a simple way to frequency offset two lasers many gigahertz apart which should find a use in atom cooling experiments, where hyperfine ground-state frequency separations are often required.
Resumo:
A novel flow-tagging technique is presented which was employed to measure gas velocities in the free stream of a shock tube. This method is based on the laser spectroscopic techniques of Laser-Enhanced Ionisation (LEI) and Laser-Induced Fluorescence (LIF). The flow in the shock tube is seeded with small amounts of sodium, and LEI is used to produce a substantial depletion of neutral sodium atom concentration in a well-defined region of the flow, by using two wavelength-resonance excitation and subsequent collisional ionisation. At a specific time delay, single-laser-pulse planar LIF is utilised to produce a two-dimensional (2-D) inverse image of the depleted tagged region downstream of the flow. By measuring the displacement of the tagged region, free stream velocities in a shock tube were determined. Large variations in the concentration of sodium seeded into the flow were observed and even in the presence of these large variations accurate free-stream velocity measurements were obtained. The experimentally determined value for velocity compares very well with the predicted velocity.