6 resultados para Flot sanguin oculaire pulsatile
em University of Queensland eSpace - Australia
Resumo:
Objectives. Pulsatile tinnitus is a rare and often disabling condition. Pulsatile tinnitus sometimes occurs in patients with severe atherosclerotic carotid stenosis. It is uncertain whether carotid endarterectomy (CEA) relieves pulsatile tinnitus in patients with severe carotid stenosis. Design, Materials and Methods. This is a retrospective study of 14 patients with pulsatile tinnitus who underwent CEA. Demographic and clinical features and pre-operative duplex results were recorded. Operative results in this group were assessed. Results. CEA relieved symptoms of pulsatile tinnitus in 10 out of 14 cases (70%). Of 10 patients that had lateralisable tinnitus and ipsilateral surgery, 9 (90%) reported symptomatic improvement. Conclusions. CEA is effective in improving pulsatile tinnitus in patients with unilateral symptoms and severe ipsilateral carotid stenosis.
Resumo:
The Oscillatory baffled reactor (OBR) can be used to produce particles with controlled size and morphology, in batch or continuous flow. This is due to the effect of the superimposed oscillations that radially mixes fluid but still allows plug-flow (or close to plug flow) behaviour in a continuous system. This mixing, combined with a close to a constant level of turbulence intensity in the reactor, leads to tight droplet and subsequent product particle size distributions. By applying population balance equations together with experimental droplet size distributions, breakage rates of droplets can be determined and this is a useful tool for understanding the product engineering in OBRs. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
An increase in left ventricular mass (LVM) occurs in the presence of type 2 diabetes, apparently independent of hypertension (1), but the determinants of this process are unknown. Brachial blood pressure is not representative of that at the ascending aorta (2) because the pressure wave is amplified from central to peripheral arteries. Central blood pressure is probably more clinically important since local pulsatile pressure determines adverse arterial and myocardial remodeling (3,4). Thus, an inaccurate assessment of the contribution of arterial blood pressure to LVM may occur if only brachial blood pressure is taken into consideration. In this study we sought the contribution of central blood pressure (and other interactive factors known to affect wave reflection, e.g., glycemic control and total arterial compliance) to LVM in patients with type 2 diabetes.
Resumo:
It is unclear whether a random plasma cortisol measurement and the corticotropin (ACTH) test adequately reflect glucocorticoid secretory capacity in critical illness. This study aimed to determine whether these tests provide information representative of the 24 hour period. Plasma cortisol was measured hourly for 24 hours in 21 critically ill septic patients followed by a corticotropin test with 1 μ g dose administered intravenously. Serum and urine were analysed for ACTH and free cortisol respectively. Marked hourly variability in plasma cortisol was evident (coefficient of variation 8-30%) with no demonstrable circadian rhythm. The individual mean plasma cortisol concentrations ranged from 286 59 nmol/l to 796 &PLUSMN; 83 nmol/l. The 24 hour mean plasma cortisol was strongly correlated with both random plasma cortisol (r(2) 0.9, P< 0.0001) and the cortisol response to corticotropin (r(2) 0.72, P< 0.001). Only nine percent of patients increased their plasma cortisol by 250 nmol/l after corticotropin (euadrenal response). However, 35% of non-responders had spontaneous hourly rises > 250 nmol/l thus highlighting the limitations of a single point corticotropin test. Urinary free cortisol was elevated (865&PLUSMN; 937 nmol) in both corticotropin responders and non-responders suggesting elevated plasma free cortisol. No significant relationship was demonstrable between plasma cortisol and ACTH. We conclude that although random cortisol measurements and the low dose corticotropin tests reliably reflect the 24 hour mean cortisol in critical illness, they do not take into account the pulsatile nature of cortisol secretion. Consequently, there is the potential for erroneous conclusions about adrenal function based on a single measurement. We suggest that caution be exercised when drawing conclusions on the adequacy of adrenal function based on a single random plasma cortisol or the corticotropin test.
Resumo:
We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.
Resumo:
We study a case of a 65-year-old woman who developed popliteal arteriovenous fistula (AVF) and venous aneurysm following left knee arthrodesis. Presenting features included left popliteal and calf pain, a tender pulsatile mass posterior to her left knee, popliteal bruit and a thrill at the popliteal fossa and ankle. Left femoral angiography showed an AVF arising from the right tibioperoneal trunk and an aneurysm at the level of the AVF. Findings at open investigation included AVF between the tibioperoneal trunk and the popliteal vein, and a venous aneurysm arising from the popliteal vein opposite the neck of the arteriovenous communication. The aneurysm and fistula were repaired using prolene suture.