102 resultados para Flexible manufacturing system

em University of Queensland eSpace - Australia


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The edge-to-edge matching model has been further developed along with the Cu/Cr system as an example. The conditions for zigzag atom rows to be matching directions are included and the critical value of interatomic spacing misfit along matching directions and the critical value of d-value mismatch between matching planes are proposed in the new version of the model. (c) 2005 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Selective laser sintering has been used to fabricate an aluminium alloy powder preform which is subsequently debound and infiltrated with a second aluminium alloy. This represents a new rapid manufacturing system for aluminium that can be used to fabricate large, intricate parts. The base powder is an alloy such as AA6061. The infiltrant is a binary or higher-order eutectic based on either Al-Cu or At-Si. To ensure that infiltration occurs without loss of dimensional precision, it is important that a rigid skeleton forms prior to infiltration. This can be achieved by the partial transformation of the aluminium to aluminium nitride. In order for this to occur throughout the component, magnesium powder must be added to the alumina support powder which surrounds the part in the furnace. The magnesium scavenges the oxygen and thereby creates a microclimate in which aluminium nitride can form. The replacement of the ionocovalent Al2O3 with the covalent AlN on the surface of the aluminium powders also facilitates wetting and thus spontaneous and complete infiltration. (C) 2004 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication of heavy-duty printer heads involves a great deal of grinding work. Previously in the printer manufacturing industry, four grinding procedures were manually conducted in four grinding machines, respectively. The productivity of the whole grinding process was low due to the long loading time. Also, the machine floor space occupation was large because of the four separate grinding machines. The manual operation also caused inconsistent quality. This paper reports the system and process development of a highly integrated and automated high-speed grinding system for printer heads. The developed system, which is believed to be the first of its kind, not only produces printer heads of consistently good quality, but also significantly reduces the cycle time and machine floor space occupation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A course which has a large student enrolment consequently puts a heavy load on instructors both in the presentation and the assessment areas. In the School of Economics at the University of Queensland, this is the case for the quantitative analysis subjects. Assessment for many years has been through mid-semester and end of semester exams, as well as Computer Managed Learning (CML) assignments. In 2000 it was decided to incorporate a system of flexible assessment where neither the CML nor the mid-semester exam was compulsory. The outcomes are assessed and the advantages and disadvantages discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Workflow technology provides a suitable platform to define and manage the coordination of business process activities. We introduce a flexible e-learning environment – called Flex-eL – that has been built upon workflow technology. The workflow functionality of Flex-eL manages the coordination of learning and assessment activities of the course process between students and teaching staff. It provides a unique environment for teachers to design and develop process-centric courses and to monitor student progress. It allows students to learn at their own pace while observing the learning guidelines and checkpoints modeled into the course process by teaching staff. We also report on the successful deployment of the concept and system for university courses and our experiences from the implementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is proposed for determining the optimal placement and controller design for multiple distributed actuators to reduce the vibrations of flexible structures. In particular, application of piezoceramic patches to a horizontally-slewing single-link flexible manipulator modeled using the assumed modes method is investigated. The optimization method uses simulated annealing and allows placement of any number of distributed actuators of unequal length, although piezoceramics of fixed equal lengths are used in the example. It also designs an linear-quadratic-regulator controller as part of the optimization procedure. The measures of performance used in the investigation to determine optimality are the total mass of the system and the time integral of the absolute value of the hub and tip position error. This study also varies the relative weightings for each of these performance measures to observe the effects on the controller designs and piezoceramic patch positions in the optimized solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: CO2 monitoring is recommended for thoracic telescopic procedures and for spontaneous breathing general anesthesia in children. During flexible bronchoscopy (FB) in children, the various currently available methods of CO2 measurements are limited. The CO2 falls and increases have been reported in FB but it is unknown whether airway lesions predispose to CO2 change. The aim of this study was to describe and validate endoscopic intratracheal CO2 measurements in children undergoing FB under spontaneously breathing GA. Methods: Endtidal CO2 (PECO2) measurements at the start (Start-CO2) and end (End-CO2) of FB on 100 consecutive children were performed using a newly designed endoscopic intratracheal method. To validate the method blood gas sampling was simultaneously performed in 28 children and results analyzed using the Bland and Altman method, intraclass correlation and 95% range for repeatability. Results: End-CO2 and CO2-change (End-CO2 minus Start-CO2) were significantly different in children with airway lesions (CO2 change: no lesion = 3 mmHg, extrathoracic airway lesion = 4.5, intrathoracic airway lesion = 8, P = 0.038). There was no significant difference in Start-CO2 values among the groups. CO2-change in those aged > 12 months was similar to those >12 months. Intratracheal CO2 measurements were comparable with arterial blood values in the Bland and Altman plots. The intraclass correlation was 0.69 and 95% range for repeatability was 3.7-4.17 mmHg. Conclusions: Midtracheal PECO2 provides a useful estimate of PaCO2 for monitoring the respiratory status of children undergoing FB. The presence of airway lesions rather than age is associated with significant increased PCO2 rise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object. Methods: Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived. Results: Magnification changes as a linear function between 100 mm ( x 1) and 10 mm ( x 9.55) and then as an exponential function between 10 mm and 3 mm ( x 40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis. Conclusion: We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The principles of sustainable development (or ecologically sustainable development as it is known in Australia) are now accepted as the foundation for natural resource management worldwide and there are increasing community expectations that they will be implemented explicitly. Previous attempts to assess sustainable development for fisheries have mostly failed because the methods have been too restrictive, often attempting to develop a single set of indicators. In 2000, all the fishery agencies and major stakeholder groups in Australia supported the development of a National ESD Framework. This initiative resulted in a practical system being generated through the results of a series of case studies and stakeholder workshops. The Australian National ESD Framework divides ESD into eight major components within the three main categories of ecological well-being, human well-being and ability to contribute: Four main steps are used to complete an ESD report for a fishery: (1) identify relevant issues, (2) prioritise these using risk assessment, (3) complete appropriately detailed reports on each issue and (4) compile the material into a report. The tools to assist this process are now available and have been used to generate reports for many Australian fisheries. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is currently no validated scoring system for quantification of airway secretions in children. A user friendly, valid scoring system of airway secretions during flexible bronchoscopy (FB) would be useful for comparative purposes in clinical medicine and research. The objective of this study was to validate our bronchoscopic secretion (BS) scoring system by examining the relationship between the amount of secretions seen at bronchoscopy with airway cellularity and microbiology. In 106 children undergoing FIB, the relationship of BS grades with bronchocalveolar lavage (BAL) cellularity and infective state (bacterial and viral infections) were examined using receptor operator curves (ROC). BAL was obtained according to European Respiratory Society guidelines; first lavage for microbiology and second lavage for cellularity Area under the ROC was significant for total cell count (TCC) and neutrophil % but not for lymphocyte %. BS grade significantly related to infection positive state (chi(2)(trend) = 5.85, P = 0,016). The area under the ROC for infection positive state versus BS grade was 0.645, 95% Cl 0.527-0.763. The BS scoring system is a valid method for quantifying airway secretions in children undergoing bronchoscopy The system related well to airway cellularity and neutrophilia, as well as to an airway infective state. However, the system is only complementary to cell counts and cultures and cannot replace these laboratory quantification techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we describe the Vannotea system - an application designed to enable collaborating groups to discuss and annotate collections of high quality images, video, audio or 3D objects. The system has been designed specifically to capture and share scholarly discourse and annotations about multimedia research data by teams of trusted colleagues within a research or academic environment. As such, it provides: authenticated access to a web browser search interface for discovering and retrieving media objects; a media replay window that can incorporate a variety of embedded plug-ins to render different scientific media formats; an annotation authoring, editing, searching and browsing tool; and session logging and replay capabilities. Annotations are personal remarks, interpretations, questions or references that can be attached to whole files, segments or regions. Vannotea enables annotations to be attached either synchronously (using jabber message passing and audio/video conferencing) or asynchronously and stand-alone. The annotations are stored on an Annotea server, extended for multimedia content. Their access, retrieval and re-use is controlled via Shibboleth identity management and XACML access policies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developing a unified classification system to replace four of the systems currently used in disability athletics (i.e., track and field) has been widely advocated. The diverse impairments to be included in a unified system require severed assessment methods, results of which cannot be meaningfully compared. Therefore, the taxonomic basis of current classification systems is invalid in a unified system. Biomechanical analysis establishes that force, a vector described in terms of magnitude and direction, is a key determinant of success in all athletic disciplines. It is posited that all impairments to be included in a unified system may be classified as either force magnitude impairments (FMI) or force control impairments (FCI). This framework would provide a valid taxonomic basis for a unified system, creating the opportunity to decrease the number of classes and enhance the viability of disability athletics.