16 resultados para Field monitoring

em University of Queensland eSpace - Australia


Relevância:

70.00% 70.00%

Publicador:

Resumo:

We study the absorption and dispersion properties of a weak probe field monitoring a two-level atom driven by a trichromatic field. We calculate the steady-state linear susceptibility and find that the system can produce a number of multilevel coherence effects predicted for atoms composed of three and more energy levels. Although the atom has only one transition channel, the multilevel effects are possible because there are multichannel transitions between dressed states induced by the driving field. In particular, we show that the system can exhibit multiple electromagnetically induced transparency and can also produce a strong amplification at the central frequency which is not attributed to population inversion in both the atomic bare states and in the dressed atomic states. Moreover, we show that the absorption and dispersion of the probe field is sensitive to the initial relative phase of the components of the driving field. In addition, we show that the group velocity of the probe field can be controlled by changing the initial relative phases or frequencies of the driving fields and can also be varied from subluminal to superluminal. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the feasibility of using semipermeable membrane devices (SPMDs) and polyethylene-based passive sampler devices (PSDs) for monitoring PAHs in stormwater. Firstly, SPMDs were deployed at one site and SPMD-derived water concentrations were compared with water concentration measured from grab samples. In a subsequent deployment the performance of SPMDs and PSDs was compared. Finally PSDs of multiple surface area to volume ratios were used to compare PAH concentrations at the two sites. The results obtained in this study show that SPMDs can be used to measure the water concentration of PAHs with reasonable accuracy, when compared with grab samples collected at the same site. Importantly, several PAHs which could not be detected in a 10 L grab sample could be detected in the SPMDs. PSD and SPMD samplers produced similar results when deployed at the same site, with most estimated water concentrations within a factor of 1.5. The use of PSDs in multiple surface area to volume ratios proved to be an effective means of characterizing the uptake kinetics for PAHs in situ. Overall passive water samplers proved to be an efficient technique for monitoring PAHs in stormwater.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Government agencies responsible for riparian environments are assessing the combined utility of field survey and remote sensing for mapping and monitoring indicators of riparian zone condition. The objective of this work was to compare the Tropical Rapid Appraisal of Riparian Condition (TRARC) method to a satellite image based approach. TRARC was developed for rapid assessment of the environmental condition of savanna riparian zones. The comparison assessed mapping accuracy, representativeness of TRARC assessment, cost-effectiveness, and suitability for multi-temporal analysis. Two multi-spectral QuickBird images captured in 2004 and 2005 and coincident field data covering sections of the Daly River in the Northern Territory, Australia were used in this work. Both field and image data were processed to map riparian health indicators (RHIs) including percentage canopy cover, organic litter, canopy continuity, stream bank stability, and extent of tree clearing. Spectral vegetation indices, image segmentation and supervised classification were used to produce RHI maps. QuickBird image data were used to examine if the spatial distribution of TRARC transects provided a representative sample of ground based RHI measurements. Results showed that TRARC transects were required to cover at least 3% of the study area to obtain a representative sample. The mapping accuracy and costs of the image based approach were compared to those of the ground based TRARC approach. Results proved that TRARC was more cost-effective at smaller scales (1-100km), while image based assessment becomes more feasible at regional scales (100-1000km). Finally, the ability to use both the image and field based approaches for multi-temporal analysis of RHIs was assessed. Change detection analysis demonstrated that image data can provide detailed information on gradual change, while the TRARC method was only able to identify more gross scale changes. In conclusion, results from both methods were considered to complement each other if used at appropriate spatial scales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dendritic cells (DC) from distinct DC subsets are essential contributors to normal human immune responses. Despite this, reliable assays that enable DC to be counted precisely have been slow to evolve. We have now developed a new single-platform flow cytometric assay based on TruCOUN(TM) beads and the whole blood Lyse/No-Wash protocol that allows precise counting of the CD14(-) blood DC subsets: CD11c(+)CD16(-) DC, CD11c(+)CD16(+) DC, CD123(hi) DC, CD1c(+) DC and BDCA-3(+) DC. This assay requires 50 mul of whole blood; does not rely on a hematology blood analyser for the absolute DC counts; allows DC counting in EDTA samples 24 It after collection; and is suitable for cord blood and peripheral blood. The data is highly reproducible with intra-assay and inter-assay coefficients of variation less than 3% and 11%, respectively. This assay does not produce the DC-T lymphocyte conjugates that result in DC counting abnormalities in conventional gradient-density separation procedures. Using the TruCOUNT assay, we established that absolute blood DC counts reduce with age in healthy individuals. In preliminary studies, we found a significantly lower absolute blood CD11c(+)CD16(+) DC count in stage III/IV versus stage I/II breast carcinoma patients and a lower absolute blood CD123(hi) DC count in multiple myeloma patients, compared to age-matched controls. These data indicate that scientific progress in DC counting technology will lead to the global standardization of DC counting and allow clinically meaningful data to be obtained. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study determined the relationship between two measures of field fertility of I I high-use Australian artificial insemination (AI) dairy bulls and thirty standard laboratory assessments of spermatozoal post-thaw viability. The two measures of field fertility used, conception rates (cCR) and non-return rates (cNRR), were both corrected for all major non-bull variables. Sperm viability assessments were conducted on semen collected within the same season as that used to derive the field fertility estimates. These assessments measured sperm concentration, motility, morphology and membrane integrity at thawing, after 2 h incubation and after the swim-up sperm selection procedure. Derivations of these measures and in vitro embryo fertilizing and developmental capacity were also determined. The Genstat Statistical Package [Genstat 5 Release 4.2 Reference Manual, VSN International, Oxford, 20001 was used to conduct an analysis of variance on the viability parameters across semen straws and bulls, and to calculate the strength of correlation between each semen parameter, cNRR and cCR in a correlation matrix. Step forward multiple regression identified the combination of semen parameters that were most highly correlated with cCR and with cNRR. The sperm parameters identified as being most predictive of cCR were the percentage of morphologically normal sperm immediately post-thaw (zeroNorm), the number of morphologically normal sperm after the swim-up procedure (nSuNorm), and the rate of zygote cleavage in vitro (Clv); the predictive equation formed by these parameters accounted for 70% of variance. The predictive equation produced for cNRR contained the variables zeroNorm, the proportion of membrane intact sperm after 2 h incubation at 37 degreesC (twoMem) and Clv and accounted for 76.5% of the variation. ZeroNorm was found to be consistent across straws and semen batches within-bull and the sperm parameter with the strongest individual predictive capacity for both cCR (P = 0.1) and cNRR (P = 0.001). Post-thaw sperm parameters can be used to predict field fertility of Australian dairy sires; the calculated predictive equations are particularly useful for identifying and monitoring bulls of very high and very low potential fertility within a group. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demonstrating the existence of trends in monitoring data is of increasing practical importance to conservation managers wishing to preserve threatened species or reduce the impact of pest species. However, the ability to do so can be compromised if the species in question has low detectability and the true occupancy level or abundance of the species is thus obscured. Zero-inflated models that explicitly model detectability improve the ability to make sound ecological inference in such situations. In this paper we apply an occupancy model including detectability to data from the initial stages of a fox-monitoring program on the Eyre Peninsula, South Australia. We find that detectability is extremely low (< 18%) and varies according to season and the presence or absence of roadside vegetation. We show that simple methods of using monitoring data to inform management, such as plotting the raw data or performing logistic regression, fail to accurately diagnose either the status of the fox population or its trajectory over time. We use the results of the detectability model to consider how future monitoring could be redesigned to achieve efficiency gains. A wide range of monitoring programs could benefit from similar analyses, as part of an active adaptive approach to improving monitoring and management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the managers of a region as large as the Great Barrier Reef, it is a challenge to develop a cost effective monitoring program, with appropriate temporal and spatial resolution to detect changes in water quality. The current study compares water quality data (phytoplankton abundance and water clarity) from remote sensing with field sampling (continuous underway profiles of water quality and fixed site sampling) at different spatial scales in the Great Barrier Reef north of Mackay (20 degrees S). Five transects (20-30 km long) were conducted from clean oceanic water to the turbid waters adjacent to the mainland. The different data sources demonstrated high correlations when compared on a similar spatial scale (18 fixed sites). However, each data source also contributed unique information that could not be obtained by the other techniques. A combination of remote sensing, underway sampling and fixed stations will deliver the best spatial and temporal monitoring of water quality in the Great Barrier Reef. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessment of the extent of coral bleaching has become an important part of studies that aim to understand the condition of coral reefs. In this study a reference card that uses differences in coral colour was developed as an inexpensive, rapid and non-invasive method for the assessment of bleaching. The card uses a 6 point brightness/saturation scale within four colour hues to record changes in bleaching state. Changes on the scale of 2 units or more reflect a change in symbiont density and chlorophyll a content, and therefore the bleaching state of the coral. When used by non-specialist observers in the field (here on an intertidal reef flat), there was an inter-observer error of I colour score. This technique improves on existing subjective assessment of bleaching state by visual observation and offers the potential for rapid, wide-area assessment of changing coral condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation. (c) 2006 Elsevier Ltd. All rights reserved.