24 resultados para Equipment Lease

em University of Queensland eSpace - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract: Purpose – The aim of this research is to determine the optimal upgrade and preventive maintenance actions that minimize the total expected cost (maintenance costs+penalty costs). Design/methodology/approach – The problem is a four-parameter optimization with two parameters being k-dimensional. The optimal solution is obtained by using a four-stage approach where at each stage a one-parameter optimization is solved. Findings – Upgrading action is an extra option before the lease of used equipment, in addition to preventive maintenance action. Upgrading action makes equipment younger and preventive maintenance action lowers the ROCOF. Practical implications – There is a growing trend towards leasing equipment rather than owning it. The lease contract contains penalties if the equipment fails often and repairs are done within reasonable time period. This implies that the lessor needs to look at optimal preventive maintenance strategies in the case of new equipment lease, and upgrade actions plus preventive maintenance in the case of used equipment lease. The paper deals with this topic and is of great significant to business involved with leasing equipment. Originality/value – Nowadays many organizations are interested in leasing equipment and outsourcing maintenance. The model in this paper addresses the preventive maintenance problem for leased equipment. It provides an approach to dealing with this problem.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

For leased equipment the lessor incurs penalty costs for failures occurring over the lease period and for not rectifying such failures within a specified time limit. Through preventive maintenance actions the penalty costs can be reduced but this is achieved at the expense of increased maintenance costs. The paper looks at a periodic preventive maintenance policy which achieves a tradeoff between the penalty and maintenance costs. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For leased equipment, the lessor carries out the maintenance of the equipment. Usually, the contract of lease specifies the penalty for equipment failures and for repairs not being carried out within specified time limits. This implies that optimal preventive maintenance policies must take these penalty costs into account and properly traded against the cost of preventive maintenance actions. The costs associated with failures are high as unplanned corrective maintenance actions are costly and the resulting penalties due to lease contract terms being violated. The paper develops a model to determine the optimal parameters of a preventive maintenance policy that takes into account all these costs to minimize the total expected cost to the lessor for new item lease. The parameters of the policy are (i) the number of preventive maintenance actions to be carried out over the lease period, (ii) the time instants for such actions, and (iii) the level of action. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to determine the frequency of use of play equipment in public schools and parks in Brisbane, Australia, and to estimate an annual rate of injury per use of equipment, overall and for particular types of equipment. Methods: Injury data on all children injured from playground equipment and seeking medical attention at the emergency department of either of the two children's hospitals in the City of Brisbane were obtained for the years 1996 and 1997. Children were observed at play on five different pieces of play equipment in a random sample of 16 parks and 16 schools in the City of Brisbane. Children injured in the 16 parks and schools were counted, and rates of injury and use were calculated. Results: The ranked order for equipment use in the 16 schools was climbing equipment (3762 uses), horizontal ladders (2309 uses), and slides (856 uses). Each horizontal ladder was used 2.6 times more often than each piece of climbing equipment. Each horizontal ladder was used 7.8 times more than each piece of climbing equipment in the sample of public parks. Slides were used 4.6 times more than climbing equipment in parks and 1.2 times more in public schools. The annual injury rate for the 16 schools and 16 parks under observation was 0.59/100000 and 0.26/100000 uses of equipment, respectively. Conclusions: This study shows that annual number of injuries per standardized number of uses could be used to determine the relative risk of particular pieces of playground equipment. The low overall rate of injuries/100000 uses of equipment in this study suggests that the benefit of further reduction of injury in this community may be marginal and outweigh the economic costs in addition to reducing challenging play opportunities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To quantify the temperature changes in the dental pulp associated with equine dental procedures using power grinding equipment. Design A matrix experimental design with replication on the same sample was followed to allow the following independent variables to be assessed: horse age (young or old), tooth type (premolar or molar), powered grinding instrument (rotating disc or die grinder), grinding time (15 or 20 seconds) and the presence or absence of water coolant. Procedure Sound premolar and molar teeth from a 6-year-old horse and a 15-year-old horse, which had been removed postmortem, were sectioned parallel to the occlusal plane to allow placement of a miniature thermocouple at the level of the dental pulp. The maximum temperature increase, the time taken to reach this maximum and the cooling time were measured (n=10 in each study). The teeth were placed in a vice and the instrument used on the tooth as per clinical situation. Results Significant differences were recorded for horse age (P < 0.001), instrument type (P < 0.001), grinding time (P < 0.001) and presence or absence of coolant (P < 0.001). There was no significant difference for tooth type. Conclusion Thermal insult to the dental pulp from the use of power instruments poses a significant risk to the tooth. This risk can be reduced or eliminated by appropriate selection of treatment time and by the use of water irrigation as a coolant. The increased dentine thickness in older horses appears to mitigate against thermal injury from frictional heat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Melodic alarms proposed in the IEC 60601-1-8 standard for medical electrical equipment were tested for learnability and discriminability. Thirty-three non-anaesthetist participants learned the alarms over two sessions of practice, with or without mnemonics suggested in the standard. Fewer than 30% of participants could identify the alarms with 100% accuracy at the end of practice. Confusions persisted between pairs of alarms, especially if mnemonics were used during learning (p = 0.011). Participants responded faster (p < 0.00001) and more accurately (p = 0.002) to medium priority alarms than to high priority alarms, even though they rated the high priority alarms as sounding more urgent (p < 0.00001). Participants with at least 1 year of formal musical training identified the alarms more accurately (p = 0.0002) than musically untrained participants, and found the task easier overall (p < 0.00001). More intensive studies of the IEC 60601-1-8 alarms are needed for their effectiveness to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the first of several tests of new auditory alarms originally proposed by Block et al. [1] and formalized in IEC 60601-1-8 for use in medical electrical equipment. We test whether participants who are supplied with the IEC-recommended mnemonics while learning label-alarm associations can more accurately identify the alarms after short periods of learning. Results for 18 participants strongly indicate that there is a mutual confusability between certain alarm pairs in both learning conditions, but that mnemonics may strengthen rather than diminish certain key confusions.