15 resultados para Energy performance rating

em University of Queensland eSpace - Australia


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the last 7 years, a method has been developed to analyse building energy performance using computer simulation, in Brazil. The method combines analysis of building design plans and documentation, walk-through visits, electric and thermal measurements and the use of an energy simulation tool (DOE-2.1E code), The method was used to model more than 15 office buildings (more than 200 000 m(2)), located between 12.5degrees and 27.5degrees South latitude. The paper describes the basic methodology, with data for one building and presents additional results for other six cases. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Six steers (3/4 Charolaisx1/4 Brahman) (mean body weight 314 +/- 27 kg) and six spayed heifers (3/5 Shorthornx2/5 Red Angus) (mean body weight 478 +/- 30 kg) were used to determine the effects of climatic conditions and hormone growth promotants (HGP) on respiration rate (RR; breaths/min), pulse rate (beats/min), rectal temperature (RT; degrees C), and heat production (HP; kJ). Cattle were exposed to the following climatic conditions prior to implantation with a HGP and then again 12 days after implantation: 2 days of thermoneutral conditions (TNL) [21.9 +/- 0.9 degrees C ambient temperature (T-A) and 61.7 +/- 22.1% relative humidity (RH)] then 2 days of hot conditions [HOT; 29.2 +/- 4 degrees C (T-A) and 78.3 +/- 13.2% (RH)], then TNL for 3 days and then 2 days of cold conditions [COLD; 17.6 +/- 0.9 degrees C (T-A) and 63.4 +/- 1.8% (RH); cattle were wet during this treatment]. The HGP implants used were: estrogenic implant (E), trenbolone acetate implant (TBA), or both (ET). Both prior to and following administration of HGP, RRs were lower (P < 0.05) on cold days and greater (P < 0.05) on hot days compared to TNL. On hot days, RTs, were 0.62 degrees C higher after compared to before implanting. Across all conditions, RTs were > 0.5 degrees C greater (P < 0.05) for E cattle than for TBA or ET cattle. On cold days, RTs of steers were > 0.8 degrees C higher than for the heifers, while under TNL and HOT, RTs of steers were 0.2-0.35 degrees C higher than those of heifers. Prior to implantation, HP per hour and per unit of metabolic body weight was higher (P < 0.05) for cattle exposed to hot conditions, when compared to HP on cold days. After implantation, HP was greater (P < 0.05) on hot days than on cold days. Under TNL, ET cattle had the lowest HP and greatest feed intake. On hot days, E cattle had the lowest HP, and the highest RT; therefore, if the potential exists for cattle death from heat episodes, the use of either TBA or ET may be preferred. Under cold conditions HP was similar among implant groups.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Stirred mills are becoming increasingly used for fine and ultra-fine grinding. This technology is still poorly understood when used in the mineral processing context. This makes process optimisation of such devices problematic. 3D DEM simulations of the flow of grinding media in pilot scale tower mills and pin mills are carried out in order to investigate the relative performance of these stirred mills. Media flow patterns and energy absorption rates and distributions are analysed here. In the second part of this paper, coherent flow structures, equipment wear and mixing and transport efficiency are analysed. (C) 2006 Published by Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Six men were studied during four 30-s all-out exercise bouts on an air-braked cycle ergometer. The first three exercise bouts were separated by 4 min of passive recovery; after the third bout, subjects rested for 4 min, exercised for 30 min at 30-35% peak O-2 consumption, and rested for a further 60 min before completing the fourth exercise bout. Peak power and total work were reduced (P < 0.05) during bout 3 [765 +/- 60 (SE) W; 15.8 +/- 1.0 kJ] compared with bout 1 (1,168 +/- 55 mT, 23.8 +/- 1.2 kJ), but no difference in exercise performance was observed between bouts 1 and 4 (1,094 +/- 64 W, 23.2 +/- 1.4 kJ). Before bout 3, muscle ATP, creatine phosphate (CP), glycogen, pH, and sarcoplasmic reticulum (SR) Ca2+ uptake were reduced, while muscle lactate and inosine 5'-monophosphate were increased. Muscle ATP and glycogen before bout 4 remained lower than values before bout I (P < 0.05), but there were no differences in muscle inosine 5'-monophosphate, lactate, pH, and SR Ca2+ uptake. Muscle CP levels before bout 4 had increased above resting levels. Consistent with the decline in muscle ATP were increases in hypoxanthine and inosine before bouts 3 and 4. The decline in exercise performance does not appear to be related to a reduction in muscle glycogen. Instead, it may be caused by reduced CP availability, increased H+ concentration, impairment in SR function, or some other fatigue-inducing agent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this and a preceding paper, we provide an introduction to the Fujitsu VPP range of vector-parallel supercomputers and to some of the computational chemistry software available for the VPP. Here, we consider the implementation and performance of seven popular chemistry application packages. The codes discussed range from classical molecular dynamics to semiempirical and ab initio quantum chemistry. All have evolved from sequential codes, and have typically been parallelised using a replicated data approach. As such they are well suited to the large-memory/fast-processor architecture of the VPP. For one code, CASTEP, a distributed-memory data-driven parallelisation scheme is presented. (C) 2000 Published by Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is becoming widely recognized that extending the larval period of marine invertebrates, especially of species with non-feeding larvae, can affect post-larval performance. As these carry-over effects are presumed to be caused by the depletion of larval energy reserves, we predicted that the level of larval activity would also affect post-larval performance. This prediction was tested with the cosmopolitan colonial ascidian Diplosoma listerianum in field experiments in southern Australia. Diplosoma larvae, brooded in the parent colony, are competent to settle immediately after spawning, and they remain competent to metamorphose for > 15 h. Some larvae were induced to metamorphose 0 to 6 h after release, whilst others were induced to swim actively by alternating light and dark periods for up to 3 h prior to metamorphosis. Juvenile colonies were then transplanted to a subtidal field site in Port Phillip Bay and left to grow for up to 3 wk. Extending the larval period and increasing the amount of swimming both produced carry-over effects on post-larval performance. Colonies survived at different rates among experiments, but larval experience did not affect survival rates. Delays in metamorphosis and increased swimming activity did, however, reduce colony growth rates dramatically, resulting in 50% fewer zooids per colony. Moreover, such colonies produced initial zooids with smaller feeding structures, with the width of branchial baskets reduced by 10 to 15%. These differences in branchial basket size persisted and were still apparent in newly budded zooids 3 wk after metamorphosis. Our results suggest that, for D. listerianum, larval maintenance, swimming, and metamorphosis all use energy from a common pool, and increases in the allocation to maintenance or swimming come at the expense of post-larval performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pathophysiology of chronic fatigue syndrome (CFS) remains unclear; however, both biological and psychological factors have been implicated in establishing or maintaining this condition. People with CFS report significant and disabling cognitive difficulties such as impaired concentration that in some cases are exacerbated by exposure to chemical triggers. The aim of this study was to determine if neuropsychological deficits in CFS are triggered by exposure to chemicals, or perceptions about the properties of these substances. Participants were 36 people with a primary diagnosis of CFS, defined according to Centers for Disease Control (CDC) criteria. A randomized, double-blind, placebo-controlled, crossover design was used, with objective assessment of neuropsychological function and participant rating of substance type, before and after exposure to placebo or chemical trigger. Results showed decrements in neuropsychological tests scores on three out of four outcome measures when participants rated the substance they had been exposed to as chemical. No change in performance was found based on actual substance type. These results suggest that cognitive attributions about exposure substances in people with CFS may be associated with worse performance on neuropsychological tasks. In addition, these findings suggest that psychological interventions aimed at modifying substance-related cognitions may reduce some symptoms of CFS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We examined the possibility that the heart of the turtle Chrysemys scripta is an exceptional anaerobic performer, by measuring myocardial power output, lactate output, and estimated ATP turnover in perfused heart preparations. Over a range of myocardial power outputs at 5 and 15 degrees C we find that turtle hearts perfused with anoxic saline do not show a particularly outstanding ability to produce ATP anaerobically. Furthermore, at 15 degrees C anoxia reduced the ATP turnover rate to 50% of the normoxic rate. At 5 degrees C the anoxia-induced depression of ATP turnover was even more pronounced, being 4-fold lower than the normoxic rate. In addition, anoxia at 5 degrees C reduced the basal metabolic rate of the turtle heart. We conclude that long-term cardiac tolerance of hypoxia in this species is more likely related to metabolic depression rather than to an exceptional anaerobic performance. (C) 1997 Elsevier Science Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: For ultra-endurance athletes, whose energy expenditure is likely to be at the extremes of human tolerance for sustained periods of time, there is increased concern regarding meeting energy needs. Due to the lack of data outlining the energy requirements of such athletes, it is possible that those participating in ultra-endurance exercise are compromising performance, as well as health, as a result of inadequate nutrition and energy intake. To provide insight into this dilemma, we have presented a case study of a 37-yr-old ultra-marathon runner as he runs around the coast of Australia. Methods: Total energy expenditure was measured over a 2-wk period using the doubly labeled water technique. Results: The average total energy expenditure of the case subject was 6321 kcal.d(-1). Based on the expected accuracy and precision of the doubly labeled water technique the subject's total energy expenditure might range between 6095 and 6550 kcal.d(-1). The subject's average daily water turnover was 6.083 L over the 14-d period and might range between 5.9 L and 6.3 L.d(-1). Conclusions: This information will provide a guide to the energy requirements of ultra-endurance running and enable athletes, nutritionists, and coaches to optimize performance without compromising the health of the participant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Supervisor ratings are useful criteria for the validation of selection instruments but maybe limited because of the presence of rating errors, such as halo. This study set out to show that supervisor ratings which are high in halo remain successful criteria in selection. Following a thorough job analysis, a customer service questionnaire was designed to assess the potential of retail sales staff on three orthogonal subscales labelled Dealing with people, Emotions and energy, and Solitary style. These subscales were uncorrelated with supervisor ratings made about 8 weeks later. However, the supervisor ratings were correlated with an overall scale derived from the three scales of the customer service questionnaire. These results support the view that supervisor ratings generally consist of global impressions and suggest that these global impressions are useful measures of overall performances. This field study confirms laboratory results that halo does not necessarily reduce rating accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The training program undertaken by many athletes will affect directly the total, habitual energy requirements of that individual. Unless that energy requirement is met via the diet and or supplementation, chronic negative energy balance will ensue, which will have both short-term and long-term effects not only on performance but also on general health. The aim of this research was therefore to determine the energy expenditure (EE) and hence energy requirements of lightweight female rowers and, further, to compare this with their self-reported energy intake (EI). Methods: The El of seven lightweight female rowers was measured using a self-reported 4-d weighed dietary record. EE was determined using the doubly labeled water (DLW) technique over a 14-d period. Results: The mean (+/-SD) age, height, and weight of the subjects was 20 (+/-1.1) yr, 168.8 (+/-4.7) cm, and 60.9 (+/-23) kg, respectively. The rowers self-reported El was 2214 (+/-313) kcal.d(-1) and their total EE was 3957 (+/-1219) kcal.d(-1). After adjusting total EE for changes in body weight (mean (+/-SD) - 1.2 (+/-1.2) kg), the comparison between adjusted El and reported showed a bias to underreporting of 1133 (+/-1539) kcal.d(-1) or 34%. The bias was not consistent across adjusted El, and two of the seven subjects overreported their intake. Conclusions: Due to the underreporting of EI, diet recording may not be an appropriate way of assessing energy requirements in lightweight female rowers. A benefit of accurately determining energy requirements, as with DLW, is that female lightweight rowers will be able to successfully manipulate their EI and achieve the set weight cut-off for participation without compromising their health or performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the impact characteristics of an ethylene vinyl acetate (EVA) mouthguard material with regulated air inclusions, which included various air cell volumes and wall thickness between air cells. In particular, the aim was to identify the magnitude and direction of forces within the impacts. Method: EVA mouthguard material, A mm thick and with and without air inclusions, was impacted with a constant force impact pendulum with an energy of 4.4 J and a velocity of 3 m/s. Transmitted forces through the EVA material were measured using an accelerometer, which also allowed the determination of force direction and magnitude within the impacts. Results: Statistically significant reductions in the transmitted forces were observed with all the air inclusion materials when compared with EVA without air inclusions. Maximum transmitted force through one air inclusion material was reduced by 32%. Force rebound was eliminated in one material, and reduced second force impulses were observed in all the air inclusion materials. Conclusion: The regulated air inclusions improved the impact characteristics of the EVA mouthguard material, the material most commonly used in mouthguards world wide.